Packard Bell PBO-1 User Manual Download Page 2

The Packard Bell Portable Oximeter quickly and accurately measures 

your oxygen (SpO2) level and pulse rate. Simply place your finger 

inside the Oximeter and quickly get an accurate reading.

WARNING

Please read these instructions carefully before using this product and 

keep the instructions and the oximeter in a safe place.

• For non-medical use. 

• This device is only intended for sports and recreational use.

• Keep out of reach of children under 12 years.

• Please follow the general safety precautions when using on children.

• This oximeter is not waterproof. Never immerse into water or other liquids.

• If damaged, do not attempt to repair the product, instead please 

contact customer support.

• Do not use the Oximeter in a magnetic resonance (MR) environment.

• Do not allow children under 12 years to take their measurements 

unattended.

• Do not use abrasive cleaning agents (see Care and Cleaning).

• Do not use the oximeter outside the specified operating and storage 

temperature ranges.

• Remove batteries when storing for long periods.

• Do not use the oximeter for purposes other than its original design.

• Avoid dropping the oximeter and protect it from severe impact and 

shock.

BUTTONS AND DETAILS

DISPLAY DESCRIPTION

Note:

 The readings might differ based on several factors such as age, 

sex, location.

INSTALLING BATTERIES

1. Open the battery cover as shown.

2. Insert two new AAA alkaline batteries 

(not included) following the polarity 

(+/-) diagram in the compartment. Do 

not mix old and new batteries, or mix 

different types or brands of battery. 

3. Close the battery cover.

USING THE OXIMETER

Before using the oximeter, make sure your finger and the oximeter’s finger 

sensor are clean. Please see “Care and Cleaning” (Page 8)

1. Press down on the edge of the oximeter and place your index finger 

into the oximeter’s finger sensor (nail side upward) as shown below.

2. Press the 

POWER

 button to turn the oximeter ON.

3. While the oximeter is working the numbers will fluctuate and the 

oximeter will beep. Keep you finger steady and wait until the 

Indicator 

graph

 displays a consistent pattern and the numbers stop fluctuating 

as shown below.

4. Take your finger out of the oximeter. The oximeter will automatically 

power off after 10 seconds of inactivity.

Note:

 If the signal strength is low, switch to another finger and perform 

the test again.

CHANGING THE DISPLAY ORIENTATION

You can change the display’s orientation by pressing the 

POWER

 button 

once. Press the 

POWER

 button again to scroll through the four orientation 

options below. 

Note

: While changing the orientation of the display, if you press the 

power button 4 times, it will also turn off the oximeter’s beeping sound. 

To turn it back on, simply press the POWER button again 4 times.

ATTACHING THE STRAP

The strap can be attached to the oximeter by following the instructions 

below:

SPECIFICATIONS

Model: PBO1

Type: Pulse Oximeter

Display: OLED

SpO2 Measuring Range: 0% - 100%

SpO2 Accuracy: ±3% in the range of 70% - 100%

                            Not defined < 70%

Pulse Rate Measuring Range: 25-250 bpm

Pulse Rate Accuracy: ±2 bpm

Peak wavelength: 666nm - 905nm

Automatic Shut-off: After 10 seconds of inactivity

Operation Environment: 5°C - 40°C; Humidity <80%

Storage Environment: -10°C - 50°C; Humidity <90%

Power Source: Two 1.5V AAA alkaline batteries

CARE AND CLEANING

Use a cotton swab moistened with alcohol (70% Isopropyl) to clean the 

oximeter casing and rubber. Do not use abrasive cleaning agents. Never 

soak the device in water or other cleaning liquids. Wait 10 minutes after 

cleaning before taking a measurement. 

Designed and distributed by Southern Telecom Inc. © 2020

All Rights Reserved.

Packard Bell® is a registered trademark of PBX Holding LLC.

Images simulated and may differ from the actual product.

Made in China.

For questions or help with your product, please visit:

www.customersupport123.com

01

Summary of Contents for PBO-1

Page 1: ...PBO 1 User Guide Portable Oximeter Measures Oxygen Level Pulse Rate ...

Page 2: ...afety precautions when using on children This oximeter is not waterproof Never immerse into water or other liquids If damaged do not attempt to repair the product instead please contact customer support Do not use the Oximeter in a magnetic resonance MR environment Do not allow children under 12 years to take their measurements unattended Do not use abrasive cleaning agents see Care and Cleaning D...

Page 3: ...ion Power button Display Strap hole Finger sensor Battery compartment 99 87 bpm 0 7 PI PR SpO2 Perfusion Index rate Pulse strength Battery power Pulse rate Pulse rate result Oxygen level result Indicator graph Oxygen level Normal Readings Oxygen level SpO2 95 100 Pulse rate PR 60 100 bpm Perfusion Index PI 0 02 20 02 ...

Page 4: ...wo new AAA alkaline batteries not included following the polarity diagram in the compartment Do not mix old and new batteries or mix different types or brands of battery 3 Close the battery cover Battery cover Two AAA alkaline batteries not included Battery cover 03 ...

Page 5: ...eter s finger sensor are clean Please see Care and Cleaning Page 8 1 Press down on the edge of the oximeter and place your index finger into the oximeter s finger sensor nail side upward as shown below 2 Press the POWER button to turn the oximeter ON Power button bpm PI PR SpO2 04 ...

Page 6: ...d the numbers stop fluctuating as shown below 4 Take your finger out of the oximeter The oximeter will automatically power off after 10 seconds of inactivity Note If the signal strength is low switch to another finger and perform the test again Indicator graph Consistent pattern 99 87 bpm 0 7 PI PR SpO2 Indicator graph Inconsistent pattern 96 77 bpm 0 7 PI PR SpO2 Numbers 05 ...

Page 7: ...n again to scroll through the four orientation options below Note While changing the orientation of the display if you press the power button 4 times it will also turn off the oximeter s beeping sound To turn it back on simply press the POWER button again 4 times Power button 99 87 bpm 0 7 PI PR SpO 2 99 87 bpm 0 7 PI PR SpO 2 06 ...

Page 8: ...ATTACHING THE STRAP The strap can be attached to the oximeter by following the instructions below Strap 1 2 3 4 07 ...

Page 9: ...tic Shut off After 10 seconds of inactivity Operation Environment 5 C 40 C Humidity 80 Storage Environment 10 C 50 C Humidity 90 Power Source Two 1 5V AAA alkaline batteries CARE AND CLEANING Use a cotton swab moistened with alcohol 70 Isopropyl to clean the oximeter casing and rubber Do not use abrasive cleaning agents Never soak the device in water or other cleaning liquids Wait 10 minutes after...

Page 10: ...com Inc 2020 All Rights Reserved Packard Bell is a registered trademark of PBX Holding LLC Images simulated and may differ from the actual product Made in China For questions or help with your product please visit www customersupport123 com 09 ...