AFX SERIES® OPERATION MANUAL
SECTION 6: FRONT PANEL OPERATION
Entire Contents Copyright
2016 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
AFX Series Power Source Operation Manual
Page 80 of 274
SOFT KEY
Description
Peak
Current (SK3)
Displays the Peak Current protection screen. This protection
function is separate from the RMS current limit function. By setting
the peak current protection mode, the maximum peak current is
limited by the power source to the programmed level. This is done
on a cycle by cycle basis. Note that a minimum setting applies as
described in section 6.4.6, next page.
The level can be set using the shuttle or key pad. To enable or
disable this function, scroll to the “Enable peak current protection”
check box and press the shuttle to toggle on or off.
Waveform (SK4)
Displays the Waveform selection screen. This function allows the
active waveform shape to be changed. Available waveform
selections are:
Sinewave, Clipped Sinewave 1% THD, Clipped Sinewave 2% THD,
Clipped Sinewave 5% THD, Clipped Sinewave 10% THD, Square and
Triangle.
Select waveform using the shuttle. Each waveform can be
previewed. With the desired waveform displayed, press the “Apply”
soft key to confirm. This will take you back to the PROGRAM screen.
Apply All (SK5)
The “Apply all” soft key is used to confirm all presets made to
program parameters in the PROGRAM screen. When pressed, all
newly set values are applied to the output and the parameter
background colors revert back to white.
Table 6-4: PROGRAM screen soft keys
Summary of Contents for 3120AFX
Page 273: ......