7
SECTION 2
SPECIFICATIONS
2.0 SPECIFICATIONS
This section states the electrical specifications of the AMX-Series Power Source. The
specifications listed apply to all models, except as noted. Some specifications are controller
dependent. These are noted as such.
2.1 ELECTRICAL
SPECIFICATIONS
2.1.1 INPUT POWER REQUIREMENTS
This paragraph lists and defines the input voltage forms that are accepted by the various
models within the AMX-Series line of equipment. Each model is listed separately. Refer to
the appropriate model when determining proper input service requirements. The input
currents listed are for operation at full rated load. Overload conditions will result in higher
input currents that still fall within the recommended input service.
The input power transformer of the AMX-Series Power Source has taps for each of the listed
power forms - one of which is selected by the factory at time of order. Once selected, the
unit will operate at designated voltage, ±10%.
MODEL 105-AMX
INPUT VOLTAGE AND INPUT CURRENT
The Model 105-AMX single phase input voltages, required input currents at full rated load and
recommended service input currents are stated as below.
INPUT
VOLTAGE
(360-440 Hz optional)
INPUT
CURRENT
SERVICE
RECOMMENDED
1) 100 VAC ±10%, 47-63 Hz
12 A
rms
25
A
2) 110 VAC ±10%, 47-63 Hz
12 A
rms
25
A
3) 120 VAC ±10%, 47-63 Hz
11 A
rms
25
A
4) 200 VAC ±10%, 47-63 Hz
6 A
rms
15
A
5) 208 VAC ±10%, 47-63 Hz
6 A
rms
15
A
6) 220 VAC ±10%, 47-63 Hz
6 A
rms
15
A
7) 230 VAC ±10%, 47-63 Hz
6 A
rms
15
A
8) 240 VAC ±10%, 47-63 Hz
6 A
rms
15
A