background image

SKU 95591/95592/95593         

  For technical questions, please call 1-800-444-3353 

PAGE 9

TO 115 VOLT, gROUndEd

gFCI OUTLET

1/8”

AIR BLEEd HOLE

BASE

(25)

dISCHARgE PIPE

(nOT InCLUdEd)

CHECK VALVE

OR

UnIOn

(nOT InCLUdEd)

FIgURE E

o

1-1/4” OR 1-1/2” 

n

PT PVC

3.  Connect the Discharge Pipe to the Base (25).  

nOTE:  

Make sure the Discharge 

Pipe is secured to a solid surface, with appropriate hardware (not included), to 

ensure the stability of the Pump. 

(See Figure E.)

Install an additional union (not included) or other means of separating the Dis-

4. 

charge Pipe just above the floor to facilitate removal of the Pump if necessary.  

(See Figure E.)

A check valve (not included) is recommended just above, or in place of, the union 

5. 

to prevent the backflow of water after each pump cycle.  If a Check Valve is used, 

1/8”

 diameter air bleed hole should be drilled through the Discharge Pipe just 

above the lower Base (25) to prevent Pump “airlock”.  

A small spray of water out of 

this hole is normal while the Pump is running.

  

(See Figure E.)

Summary of Contents for 95591 - .75 HP

Page 1: ...eight Tools 3491 Mission Oaks Blvd Camarillo CA 93011 Visit our website at http www harborfreight com Read this material before using this product Failure to do so can result in serious injury Save th...

Page 2: ...ollowing pages may result in electric shock fire and or serious injury SAVE THESE INSTRUCTIONS REV 08b 09a SPECIFICATIONS Model 95591 Model 95592 Model 95593 Motor 115 V 60 Hz 4 A 3 4 HP 115 V 60 Hz 5...

Page 3: ...out let only one way If the plug does not fit fully in the outlet reverse the plug If it still does not fit con tact a qualified electrician to install a polarized outlet Do not change the plug in an...

Page 4: ...of electric shock or injury SPECIFIC SAFETY RULES Maintain labels and nameplates on 1 the Pump These carry important information If unreadable or miss ing contact Harbor Freight Tools for a replacemen...

Page 5: ...ician install within 10 feet of where the Pump will be located a 115 volt GFCI electrical outlet that is dedicated only to the Pump Any outlet should be above the water line NEVER raise or lower the P...

Page 6: ...nding provides a low resistance path to carry electricity away from the user reducing the risk of electric shock See 3 Prong Plug and Outlet The grounding prong in the plug is 2 connected through the...

Page 7: ...If you are using one extension cord 5 for more than one tool add the nameplate amperes and use the sum to determine the required minimum cord size See Table A If you are using an extension cord 6 out...

Page 8: ...Assembly Diagram on page 13 WARNING Always make sure to turn off the electricity powering the Pump s electrical outlet and that the Pump is unplugged from its outlet prior to assembling the unit uncl...

Page 9: ...e the stability of the Pump See Figure E Install an additional union not included or other means of separating the Dis 4 charge Pipe just above the floor to facilitate removal of the Pump if necessary...

Page 10: ...dry Doing so will increase wear to the unit and possibly cause seal damage See Figure E Note This Pump has a built in thermal protector for the Motor which automatically shuts it off to avoid overhea...

Page 11: ...ON All maintenance service or repairs not mentioned in this manual must only be performed by a qualified service technician TROUBLESHOOTING Problem Possible Solution Pump does not start Plug the Pump...

Page 12: ...AND LIABILITY ARISING OUT OF HIS OR HER REPAIRS TO THE ORIGINAL PRODUCT OR REPLACEMENT PARTS THERETO OR ARISING OUT OF HIS OR HER INSTALLATION OF REPLACEMENT PARTS THERETO PARTS LIST Part Description...

Page 13: ...AGRAM 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 32 31 Power Cord Plug not shown Note Some parts are listed and shown for illustration purposes only and are not a...

Page 14: ...perty or for incidental contingent special or con sequential damages arising from the use of our product Some states do not allow the exclusion or limitation of incidental or consequential damages so...