10.
RECOVERY SYSTEM
RECOVERY TANK
To drain and rinse the recovery tank:
1.
Lift the hose off the holder and lower the hose end to the desired drain location
2.
Remove the press-fit cap from the drain hose and squeeze the restriction collar to control the flow
3.
As the tank drains, lift the recovery tank lid to the fully open position
4.
Thoroughly clean and rinse out the sediment from the bottom of the tank with a clean water hose
Periodically use cleaner and sanitizer with a cloth or sponge to prevent mold and mildew
5.
Inspect and clean the debris tray and the vacuum mesh filter screen and ball float system
6.
Leave the lid open to dry
SQUEEGEE BLADES INSPECTION AND SELECTION
SQUEEGEE ASSEMBLY SETUP
Inspect and maintain the squeegee system to achieve peak machine performance.
REMOVAL AND INSTALLATION:
Install: Align the assembly, attach the vacuum hose, and tighten the easy grip knobs.
Remove: Loosen the easy-grip knobs and detach the recovery hose (reverse of installation).