PRE-USE SETUP
The key switch is located on the control panel. When the machine is not in use, remove the key and store it in a
secure location.
TURNING THE UNIT ON/OFF
CIRCUIT BREAKERS
The circuit breakers on the control panel protect the components from high amp-draw. In particular, the scrub
head circuit will draw too many amps when overloaded by improper application setup. Solution flow, floor sur
-
face, and down-pressure should be considered when operating the machine (example: high down-pressure on a
rough floor with no solution flow will overload the circuit). Repeatedly tripping the breaker will cause the need
for replacement.
BATTERY POWER LEVEL & FAULT INDICATOR
BATTERY POWER LEVEL & FAULT INDICATOR
When switched to the ON position, the Battery Power Level Indicator illuminates indicating
the battery charge level. A full charge is indicated when all LEDs are lit. As the power level
decreases, the LEDs go out from right to left.
When the battery charge is depleted, the last red LED will flash and the brush motor will turn off. The vacuum
and traction drive will continue to function allowing final water recovery and transport to the charging station.
NOTE
: Using AGM battery-equipped units after the last yellow LED goes out can reduce the life of the
batteries.
NOTE
: After a fill charge, operate the machine for at least 30 minutes before recharging the batteries again. Do
not leave the batteries discharged overnight.
A flashing B
attery Power Level Indicator
indicates a detected fault. The following is a list of fault codes:
The battery needs to be charged or there is a faulty connection to the battery.
Check the connection to the motor.
The motor has a short circuit.
The controller is being inhibited from driving.
Throttle fault, check the connection.
Controller fault, check connections
Parking brake fault, check the motor connections.
Excessive voltage, check the battery connections.
Summary of Contents for S-24
Page 25: ...RETURN TO TABLE OF CONTENTS 21 PAGE INTENTIONALLY BLANK...
Page 49: ...RETURN TO TABLE OF CONTENTS 45 PAGE INTENTIONALLY BLANK...
Page 55: ...RETURN TO TABLE OF CONTENTS 51 PAGE INTENTIONALLY BLANK...
Page 58: ...RETURN TO TABLE OF CONTENTS 54 PRIOR TO SERIAL NUMBER 121567 S 28 DISK SCRUB HEAD...
Page 60: ...RETURN TO TABLE OF CONTENTS 56 AFTER SERIAL NUMBER 121567 S 28 DISK SCRUB HEAD...
Page 62: ...RETURN TO TABLE OF CONTENTS 58 S 32 SCRUB HEAD PRIOR TO SERIAL NUMBER 121567...
Page 64: ...RETURN TO TABLE OF CONTENTS 60 S 32 SCRUB HEAD AFTER SERIAL NUMBER 121567...
Page 69: ...RETURN TO TABLE OF CONTENTS 65 PAGE INTENTIONALLY BLANK...
Page 75: ...RETURN TO TABLE OF CONTENTS 71 OPTIONAL CHEMICAL INJECTION WIRING DIAGRAM...
Page 76: ...RETURN TO TABLE OF CONTENTS 72 DATE MAINTENANCE LOG...
Page 77: ...RETURN TO TABLE OF CONTENTS 73 DATE MAINTENANCE LOG...
Page 78: ...RETURN TO TABLE OF CONTENTS 74 PAGE INTENTIONALLY BLANK...
Page 80: ...www pacificfloorcare com...