15
TRNT.BODYA
5055.45-A 021115-40
Installer information
Clearances to combustibles
Minimum Clearance to Combustible Materials
INTERIOR SIDE WALL 4”
INTERIOR BACK WALL
4 “
INTERIOR CEILING
18”
VENTING PIPE CLEARANCE
1”
4”
4”
1”
4”
4”
4”
1”
4”
Vertical venting
Horizontal venting
Vertical venting
Vertical venting
Horizontal venting
4”
4”
1”
1”
“
LOCATION EXAMPLES INCLUDE MINIMUN
CLEARANCES TO COMBUSTIBLE MATERIAL
Locating the Gas stove
Location Note:
The Trenton can be
installed directly onto
any flooring material
without an additional
floor protector. Only
requirement is that
the floor be stable
and strong enough to
support the stove
Note on corner placement:
Refer to minimum clearances as shown
in (Figure 22) & (Figure 23). Refer to
(Figure 24) for venting allowances.
4”
4”
18”
MIN.
Figure 22:
Trenton clearance to combustibles.
Figure 23:
Trenton common locations & minimum allowances.