SUMINSERTA    260407-20

....... Surround Trim,  Set (** Over-size, not shown) .........................  
SINS.3549
2..... Surround Top  (* Standard-size) ............................. SINS.3516
....... Surround Top  (** Over-size, not shown) ................ SINS.3546
3..... Bay Top  (c/w Washers and Nuts) .......................... SINS.3535
4..... Casing Top, Back ............................................................ 3502
5..... Casing Top, Front ......................................................... 3502.5
6..... Casing Back .................................................................... 3504
7a ... Air Defl ector, Center .......................................................... 506
7b .. Air Defl ector, Right ......................................................... 506.5
8..... Rear Handle  (2 pcs. required) ........................................... 512
9..... Surround Side, Left  (* Standard-size) .................. SINS.35155
....... Surround Side, Left  (** Over-size, not shown) ........................  
SINS.35455
10... Front Panel, Left .............................................................. 3509
11... Casing Side, Left ............................................................. 3503
11a . Surround Clip  (2 pcs. required) ........................................ 537
12... Panel Standoff  (2 pcs. required) .................................... 510.1
13... Blower Standoff ................................................................. 510
14... Door Catch  (c/w Bolt) ......................................... WODC.1461
15... Ash Lip  (c/w Gold Trim) .................................. SUMM.321001
....... Ash Lip only ......................................................... ALIP.321001
....... Ash Lip Hardware .................................................... ALIP.3211
....... Ash Lip Trim, Gold .......................................................... 323.5
....... Ash Lip Trim, Nickel ........................................................ 323.6
16... Front Cover Panel ............................................................ 3514
17... Panel Standoff Spacer ................................................... 510.2
18... Casing Bottom ................................................................ 3501
19... Casing Side, Right ........................................................ 3503.5

20... Front Panel, Right ................................................. SINS.35095
21... Surround Side, Right  (* Standard-size) ................. SINS.3515
....... Surround Side, Right  (** Over-size, not shown) ..... SINS.3545
22... Surround Hardware Package  ......................... WINS.SMHDW
23... EBT Gasket ..................................................................... 3237
24... EBT  (c/w Gasket #3237 and Rivets) .................... SUMM.EBT
25... Air Control Cover ...................................................... 3536.001
26... Air Shutter Assembly  (c/w Spring. Washer and Cap) .............
SUMM.531
27... Glass Clamp  Kit (c/w Screws) .............................. SUMM.142
28... Glass Bar  Kit (2 pcs.) .......................................... SUMM.3125
....... Glass Gasket Kit  (not shown) ...................................... 2083.1
29... Rep. Glass  (c/w Glass Gasket) ....................................... 2083
30... Door Gasket Kit .................................................. DRSM.20832
31... Door Casting, Arched Black .................................CAST.SMST
....... Door Casting, Arched Gold .................................CAST.SMGD
32... Door Handle Assembly  (c/w Wood Handle and Nut) .............
WODC.4147
33... Baffl e Pin ........................................................................... 125
34... Brick Rail  (2 pcs. required) ................................. SUMM.3122
35... Baffl e Insulation Kit  (3 pcs.) ....................................... 5068.75
36... Baffl e ................................................................... SUMM.3111
37... Baffl e Gasket ................................................................ 3139.5
38... Flame Shield  (c/w Bolt, Washer and Nut) .............. SINS.3513
39... Boost Manifold ............................................................. 3105.1
40... Firebrick - 9" x 4 1/2" x 1 1/4" (19 pcs. required) ....... 5096.99
41... Firebrick - 7 1/4" x 4 1/2" x 1 1/4" (1 pcs. required) ......... 245
42... Firebrick - 9" x 3 1/2" x 1 1/4" (2 pcs. required) ......................  
3245.5

Replacement Parts

(WHEN ORDERING, INCLUDE PART NUMBER WITH DESCRIPTION)

ITEM 

DESCRIPTION 

PART NO. 

ITEM 

DESCRIPTION 

PART NO.

1..... Surround Trim,  Set (* Standard-size) ..................... SINS.3519

....... Firebrick Set ...........................................................BRIC.SINS
43... Replacement Blower Assembly  (c/w Cord, Switch) WINS.BLOW
....... Blower Only .................................................................. 5024.6

* ..... Standard-Size Surround Assembly, Embossed Panels ..........  

48 3/4" wide x 32" high

** .... Over-Size Surround Assembly, Plain Panels ...........................  

 

52 3/4" wide x 34" high

Summary of Contents for SUMMIT WOOD INSERT DESIGN-A

Page 1: ...ilding or officials about restrictions and installation inspection requirements in your area IMPORTANT THESE INSTRUCTIONS ARE TO REMAIN WITH THE HOMEOWNER TESTED and LISTED to ULC S628 UL 1482 Meets t...

Page 2: ...rical Supply 9 Operation 10 Wood Selection 10 How to Test Your Wood 10 Lighting the Fire 10 Normal Operation 10 Restarting After Extended or Overnight Burns 10 More Wood More Heat 11 Proper Draft 11 A...

Page 3: ...For your safety follow the installa tion directions Consult local building or fire officials about restrictions and installation inspection requirements in your area The services of competent installe...

Page 4: ...above an adjacent combustible floor and must extend 16 in front and 8 beyond each side of the fireplace opening Ember protection Combustible floor beyond the hearth must be protected from hot embers...

Page 5: ...ood burning use Check for creosote build up or other obstructions especially if it has not been in use for some time The existing fireplace damper is to be locked open or re moved completely WARNING D...

Page 6: ...ar adjusting legs to level the Insert Note For better access the top of the casing may be re moved Fig 4 If it is necessary to get access to the connector pipe through the flue outlet of the Insert th...

Page 7: ...ieces using the enclosed hardware Slide part F into the back corners of the trim and tighten screws Ensure the mitred corners fit tightly and evenly Fig 6 4 Slide the assembled trim over the surround...

Page 8: ...in the reverse order to their removal 8 Slide pre assembled surround into the friction fit tabs on the inside of the outer casing DO NOT LIFT THE SURROUND ASSEMBLY BY GRASPING THE TRIM The surround is...

Page 9: ...atically push the rocker switch to the 0 or OFF position and set the fan speed control to a desired setting This will allow the blower to turn on automatically once the Insert has come up to operating...

Page 10: ...ition and open door 2 Place crumpled newspaper in the centre of the heater and criss cross with several pieces of dry kindling Add a few small pieces of dry wood on top 3 Ignite the paper and close th...

Page 11: ...anty and could be very hazardous More Wood More Heat Seasoned wood has approximately 7500 BTU s per pound If you put 10 pounds of wood in your stove for an eight hour burn the wood will be producing 9...

Page 12: ...th a full load on a hot bed of coals and with the air inlet wide open Creosote Formation and Need for Removal When wood is burned slowly it produces tar and other organic vapours which combine with ex...

Page 13: ...Replacement glass can be obtained from your Dealer The size required is 9 1 8 x 15 5 8 Pacific Insert or 9 7 8 x 17 7 8 Summit Insert x 5 mm Robax Ceramic glass must be used Do not substitute with an...

Page 14: ...r for combustion Glass is Dirty 1 See 1 2 and 3 above 2 Door Gasket leakage Replace gasket Check latch Low Heat Output 1 Wood is wet Use dry wood 2 Fire too small Build a larger fire Won t Burn Overni...

Page 15: ...optional one is being in stalled one full size brick D will not be needed for your installation With the woodstove in the upright position install firebricks as follows 1 Place the firebricks on the...

Page 16: ...INS SMHDW 23 EBT Gasket 3237 24 EBT c w Gasket 3237 and Rivets SUMM EBT 25 Air Control Cover 3536 001 26 Air Shutter Assembly c w Spring Washer and Cap SUMM 531 27 Glass Clamp Kit c w Screws SUMM 142...

Page 17: ...SUMINSERTA 260407 20 17 Fig 18...

Page 18: ...storage and the thermal insulation keeps the combustion zone hot Active flaming takes place during the first part of the burn During this storage heat is stored in the mass of the unit and is later r...

Page 19: ...ECTION ASSEMBLY OPTIONAL COMPONENTS FAN KIT ELECTRICAL RATING 115V 60HZ 1 AMP DANGER RISK OF ELECTRICAL SHOCK DISCONNECT POWER BEFORE SERVICING UNIT ROUTE CORD AWAY FROM UNIT FOR USE WITH SOLID WOOD F...

Page 20: ...PACIFIC ENERGY FIREPLACE PRODUCTS LTD Technical Support 1 887 715 2398 www pacificenergy net 2975 Allenby Rd Duncan B C V9L 6V8 Printed in Canada...

Reviews: