130715-24
7
©PACIFIC ENERGY FIREPLACE
PRODUCTS LTD.
Maintenance Checks
Check the following parts for damage such as cracks, excessive corrosion, burned out sections and excessive warping:
(See website for descriptions and more detail)
Some warping of the baffle is normal(up to 1/4” or .65cm). Replace if the baffle has permanent warping greater than this or
has signs of cracking or breakage.
Weekly:
- Firebrick - for cracking.
- Door Gasket - sagging, placement, damage.
Monthly:
- Brick rail tabs and brick rails.
- Air riser tube in the back of the firebox.
- Back side of airwash chamber - located in the upper front of firebox.
- Baffle locking pin.
- Boost tube cover - located in center of manifold, bottom front of firebox.
When Cleaning the
Chimney System:
- Top baffle board/blanket.
- Baffle.
- Brick Rails.
- Manifold - located in bottom front of firebox.
Blower:
- The blower should be cleaned out a minimum every six months by using a vacumn on the grill openings in the back and
bottom of the blower casing to remove any dust and debris.
- Please contact your dealer if you experience any of the damage listed above. Continuing to operate your stove with bro-
ken parts may accelerate damage to other parts and may void your warranty