Safety and Maintenance
NOTE: WE STRONGLY RECOMMEND THAT SMOKE AND CARBON MONOXIDE DETECTORS BE
INSTALLED IN THE AREA WHERE THE HEATER IS TO BE INSTALLED.
If smoke detectors have been previously installed, you may notice that they are operating more frequently.
This may be due to curing of stove paint or fumes caused by accidentally leaving the fire door open. Do not
disconnect the detectors.
1. Burn only, dry and well seasoned cord wood.
The denser or heavier the wood when dry, the greater its
heat value. This is why hardwoods are generally preferred. Green or wet wood should not be used, it will
reduce heat output, as well as, contribute significantly to creosote buildup.
WARNING: NEVER USE CHEMICALS OR ANY OTHER VOLATILE LIQUID TO START A FIRE. DO
NOT BURN GARBAGE OR FLAMMABLE FLUIDS SUCH AS GASOLINE, NAPHTHA, OR ENGINE OIL.
WE STRONGLY RECOMMEND THAT SMOKE DETECTORS BE INSTALLED.
WARNING:
This unit is not designed to be operated with the firing door open. In addition to the obvious
hazard of sparks landing on combustibles, an open fire door will cause the heater to draw excess air from
the living space and possibly cause suffocation.
2. Remove ashes frequently. Embers can roll out the door and create a fire hazard. Maintain a 1”(25mm)
minimum ash base.
3. The area where boost combustion air enters the firebox must be kept clear of excessive ash buildup
which will block air flow. This area is at the front of the firebox.
4. If glass becomes darkened through slow burning or poor wood, it can be cleaned with fireplace glass
cleaner when the fireplace is cold. Never scrape with an object that might scratch the glass. The type and
amount of deposit on the glass is a good indication of the flue pipe and chimney buildup. A light brown
dusty deposit that is easily wiped off usually indicates good combustion and dry, well-seasoned wood and
therefore relatively clean pipes and chimney. On the other hand, a black greasy deposit that is difficult to
remove is a result of wet and green wood and too slow a burning rate. This heavy deposit is building up as
quickly in the chimney.
5. Establish a routine for the fuel, wood burning and firing technique. Check daily for creosote buildup until
experience shows how often you need to clean to be safe.
WARNING: ONLY USE MATERIALS AND
COMPONENTS SUPPLIED OR SPECIFIED BY THE MANUFACTURER WHEN DOING MAINTENANCE
OR REPLACEMENTS. DO NOT USE A FIREPLACE INSERT OR OTHER PRODUCTS NOT SPECIFIED
FOR USE WITH THIS FIREPLACE.
6. DOOR GASKETS - The gasket used by Pacific Energy (7/8”(22mm) medium density fibreglass rope)
requires only light pressure to seal. This will prolong seal life. It is important that the door seal be main-
tained in good condition. Periodically inspect seals and replace if necessary.
7. DOOR GLASS - Replacement glass can be obtained from your dealer. Use 11 3/8” (289mm) x 21 5/8”
(549mm) x 5 mm ceramic glass only.
WARNING: DO NOT SUBSTITUTE GLASS WITH ANY OTHER TYPE MATERIAL OTHER THAN CERAMIC
GLASS
4
100001385_071118-40
FP25
Summary of Contents for FP25
Page 39: ...39 100001385_071118 40 FP25...