Hearth Mount Installation
Warning:
Carefully follow the applicable guidelines laid out in the previous installation section plus these addition
guidelines.
- DO NOT INSTALL IN A SLEEPING ROOM.
- BOTH CHIMNEY SYSTEM AND CONNECTOR MUST BE LISTED TO:
IN CANADA - ULC S-641 LISTED CONNECTOR AND ULC-S-629 LISTED CHIMNEY,
IN USA - UL-103 HT LISTED CONNECTOR AND CHIMNEY
- Do NOT use single wall "smoke pipe" for the connector.
- Outside air supply must be used for Mobile Home installations see "Combustion Air" on page 19.
- Remove the chimney down to the roof flashing to allow for transportation of the mobile home.
Clearances
This heater must be installed with a listed double-wall connector and compatible chimney system. Clearances to com-
bustible surfaces and materials are shown in Figure 14. Consult local fire codes and authorities for final approval.
NOTE:
Install all components to the connector or chimney manufacturer's installation requirements. Consult your chim-
ney supplier for installation advice.
CAUTION: THE STRUCTURAL INTEGRITY OF THE MOBILE HOME FLOOR, WALL AND CEILING/ROOF MUST BE
MAINTAINED.
- The services of a competent or certified installer, (certified by the Wood Energy Technical Training program (WETT) - in
Canada, Hearth Education Foundation (HEARTH) - in U.S.A.,) are strongly recommended.
Additional Mobile Home Requirements
Non-combustible
floor protector
Minimum 7' (2.1m.)
Ceiling Height from
bottom of legs
8” (200mm)
14” (355mm)
Fully lined Chim-
ney or Sealed
throat as per local
or National fire
codes.
Ensure that the Masonry chimney
meets all National Fire Protection
Association and local building codes.
Have the chimney cleaned and
inspected by a professional to ensure
there are no cracks, weak mortar or
other signs of deterioration. See pipe
manufacturers installation instructions
for further information.
Figure 18: Alt 1.2 Hearth Mount.
210618-28_ALT 1.2
18
5055.7298-A