In Canada: 18" (457 mm) on
the firing side and 8" (203 mm)
to the other sides (Figure 4).
Floor Protector
The stove may be installed on a combustible floor provided noncombustible ember protection is used.
This protection must extend as follows:I
In USA: 16" (406 mm) to the front and 8"
(203 mm) to the sides of the fuel loading
door opening. (Figure 3). This protection
is also required under the chimney
connector and 2" (51 mm) beyond each
side if using any horizontal venting.
16" [406mm]
8"
203mm
8"
203mm
U.S.A. Only
Minimum Width - 36"(914mm)
Minimum Overall Depth - 40 1/2"(1.03m)
Non-combustible
floor protector
3"
76mm
Figure 3: T6 Floor protector - USA .
Canada Only
18" [457mm]
Minimum Width - 43”(1.09m)
Minimum Overall Depth - 50 1/2”(1.28m)
18" [457mm]
8"
203mm
8"
203mm
Non-combustible
floor protector
8"
203mm
Figure 4: T6 Floor protector - Canada.