11
ALT5.ASCINSB 150714-24
©PACIFIC ENERGY FIREPLACE
PRODUCTS LTD.
Installation
Warning:
Under no circumstances is this heater to be installed in a makeshift
or “temporary” manner. It may be fi red only after the stove is installed
properly.
DO NOT ATTEMPT TO CONNECT THIS HEATER TO ANY AIR
DISTRIBUTION DUCT.
Outside combustion air or fresh air into the room may be required in
your area, consult local building codes (see Combustion Air section).
WARNING: THE APPLIANCE AND FLUE-SYSTEM SHALL BE
INSTALLED IN ACCORDANCE WITH AS/NZS 2918 AND THE
APPROPRIATE REQUIRMENTS OF THE RELEVANT BUILDING
CODE OR CODES
WARNING: APPLIANCES INSTALLED IN ACCORDANCE WITH
THIS STANDARD SHALL COMPLY WITH THE REQUIREMENTS
OF AS/NZS 4013 WHERE REQUIRED BY THE REGULATORY
AUTHORITY, I.E. THE APPLIANCE SHALL BE IDENTIFIABLE
BY A COMPLIANCE PLATE WITH THE MARKING ‘TESTED TO
AS/NZS 4013’.
ANY MODIFICATION OF THE APPLIANCE THAT HAS NOT BEEN
APPROVED IN WRITING BY THE TESTING AUTHORITY IS CON-
SIDERED TO BE IN BREACH OF THE APPROVAL GRANTED FOR
COMPLIANCE WITH AS/NZS 4013.
CAUTION: MIXING OF APPLIANCE OR FLUE-SYSTEM COM-
PONENTS FROM DIFFERENT SOURCES OR MODIFYING THE
DIMENSIONAL SPECIFICATION OF COMPONENTS MAY RESULT
IN HAZARDOUS CONDITIONS. WHERE SUCH ACTION IS CON-
SIDERED, THE MANUFACTURER SHOULD BE CONSULTED IN
THE FIRST INSTANCE.
CAUTION: CRACKED OR BROKEN COMPONENTS, e.g. GLASS
PANELS OR CERAMIC TILES, MAY RENDER THE INSTALLATION
UNSAFE.
WARNING: ANY MODIFICATION OF THE APPLIANCE THAT HAS
NOT BEEN APPROVED IN WRITING BY THE TESTING AUTHOR-
ITY IS CONSIDERED AS BREACHING AS/NZS 4013.
CAUTION: THIS APPLIANCE SHOULD NOT BE OPERATED WITH
A CRACKED GLASS.
CAUTION: THIS APPLIANCE SHOULD BE MAINTAINED AND
OPERATED AT ALL TIMES IN ACCORDANCE WITH THESE IN-
STRUCTIONS.
CAUTION: THE USE OF SOME TYPES OF PRESEVATIVE-TREATED
WOOD AS A FUEL CAN BE HAZARDOUS.
DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE
SERVICING ANOTHER APPLIANCE.
Fireplace Specifi cations
Your fi replace is required to have the following minimum sizes:
WIDTH (at front)
622mm
WIDTH (at rear)
610 mm
HEIGHT 533
mm
DEPTH
464
mm
Chimney height 4.5m (minimum)
Into a Masonry Fireplace
Inspect your fi replace for cracks, loose mortar or other physical
defects. If repairs are required, they should be completed before
installing your insert.
The fi replace chimney must be suitable for wood burning use.
Check for creosote build up or other obstructions, especially if it
has not been in use for some time - have chimney swept.
The existing fi replace damper is to be locked open or removed
completely.
The services of a competent or certifi ed installer are strongly
recommended to install or commission this installation.
WARNING: Do not remove bricks or mortar from your
existing fi replace.