AeGIS 7000V
Page 19
Default is 60 seconds
1. Enter function code 70 then press #
2. Press 010-180 then press #
71
DOOR OPEN TIME
04-99 Seconds
Default is 12 seconds
Must be in programming mode, see
1. Enter function code 71 then press #
2. Press 04-99 then press #
72
LOCK OUT COUNT
1-9 Times
Default is 3 times
Must be in programming mode, see
1. Enter function code 72 then press #
2. Press 1-9 then press #
73
TONE OR PULSE
Not Applicable
Not applicable
74
AUTO ANSWER
1= enable
0= disable
Default is 1 (enable)
The system will answer incoming call between 2
nd
-
4
th
ring. Press * to establish two ways communication
with the person at the system
Must be in programming mode, see
1. Enter function code 74, then press #
2. Press 1= enable or 0= disable then press #
75
KEYPAD BEEP OFF
1= enable (beep on)
0= disable (beep off)
Default is 1 (enable)
Must be in programming mode, see
1. Enter function code 75 then press #
2. Press 1= enable or 0= disable then press #
76
OPENNING DOOR BEEP OFF
1= enable (beep on)
Must be in programming mode, see
WARNING: SYSTEM WILL BE DISABLED
FOR 90 SECONDS IF INVALID ACCESS CODE HAS
BEEN ENTERED ACCORDING TO THE SETTING OF
LOCK-OUT COUNT.
TALK TIME:060
DOOR OPEN:12
LOCK-OUT CNT:3
AUTO ANSWER=1:1
BEEP On=1Off=0:1