5.  Enter 4-digit access code then press #. 

Repeat step 1 to edit another tenant directory. 
 

03 

DELETING A DIRECTORY

 

 

 

Must be in programming mode, see 

Two ways to 

Log-on to programming mode:

 on page 13 

 

1.  Enter function code 03 then press # 

 
 
 
 

2.  Enter directory number to be deleted  (i.e. 

directory 001) then press # 
 
 
 
 

04 

DELETING ALL DIRECTORY

 

 

Must be in programming mode, see 

Two ways to 

Log-on to programming mode:

 on page 13 

 

1.  Enter function code 04 then press # 

 
 
 

2.  Press 13 then # 

 
 
 
 

3.  Press 5 then # 

 

05 

MANUAL OPEN AND CLOSE RELAY 1 

00= close 

01-99= open 01-98 hours timer 

99= open for indefinite time

 

 
 
 

Must be in programming mode, see 

Two ways to 

Log-on to programming mode:

 on page 13 

 

1.  Enter function code 05 then press # 

 
 

 
  

 
2.  Enter 01-98 hours timer, 00=close or 99= open 

for indefinite time then press #, hear 

beep 

beep!!!

 

 

06 

DIRECTORY DIGIT 

2, 3 or 4 digit  

Default is 3-digit

 

Must be in programming mode, see 

Two ways to 

Log-on to programming mode:

 on page 13 

 

1.  Enter function code 06 then press # 

 
 
 
 
 

2.  Replace the directory digit to 2 or 4 digit, then 

Delete

 

Dir:

 

_

 

_

 

_

001

 

is

 

deleted!

Delete

 

all

 

?

 

13

Are

 

you

 

sure

 

?

 

5

DIR

 

DIGITS:

 

3

NOTE:

 

IF

 

DIRECTORY

 

DOES

 

NOT

 

EXIST,

 

THE

 

DISPLAY

 

WILL

 

SHOW

 

Error

 

on

 

Delete

 

!

 

OPEN:

 

00

 

HOURS

 

NOTE:

 

ALL

 

TENANT

 

DIRECTORIES

 

MUST

 

HAVE

 

SAME

 

NUMBER

 

OF

 

DIGIT

 

Summary of Contents for AEGIS 7250P

Page 1: ...INSTALLATION AND PROGRAMMING MANUAL Rev 05 16 2012...

Page 2: ...BLE OF CONTENTS Chapter 1 GETTING STARTED 4 Chapter 2 INSTALLATION WIRING DIAGRAM 11 Chapter 3 PROGRAMMING 13 Chapter 4 SYSTEM S OPERATION 21 Chapter 5 TROUBLE SHOOTING GUIDE 23 GENERAL FCC REQUIREMEN...

Page 3: ...the information herein implied Pach and Company does not assume any liability for any damages which may arise in installation or use of the AeGIS 7000P Series Pach and Company does not assume liabili...

Page 4: ...own access code which is entered on the system keypad The tenants MUST have a telephone to allow remote visitor access Also as a standard feature the tenant is allowed to call the Aegis unit and conve...

Page 5: ...o Relay Output Form C Dry Contact 120 VAC 10A 24VDC 10A 250VAC 7A o Memory Type Non volatile o Tone Detection Crystal controlled capable of detecting short bursts 80 ms o Ringer Equivalence 0 6B o Mou...

Page 6: ...buy direct from Pach and Company or through Pach and Company s normal distribution channels Pach and Company does not warrant this product in any way to the end user consumer Consumers must obtain war...

Page 7: ...rcumstances will Pach and Company honor warranty any product found to have been altered repaired and or modified by the end user consumer o Pach and Company reserves the right to repair the product or...

Page 8: ...ing the course of daily product operation o Pach and Company is not responsible for the time travel and or labor costs of any distributor and or dealer installer including but not limited to any expen...

Page 9: ...he selling dealer and or installer as to the nature of the dealer s warranty if any All contact to Pach and Company from the end user consumer will be referred to the consumer s selling dealer and or...

Page 10: ...r and or dealer installer including but not limited to any expenses to install uninstall or reinstall hardware software firmware related to warranty issues product enhancements or product failures IMP...

Page 11: ...AeGIS 7000P Page 11 Chapter 2 INSTALLATION WIRING DIAGRAM Checking your installation Figure 2 1...

Page 12: ...djust the speaker volume press wait for dial tone clockwise decrease counter clockwise increase refer to figure 2 1 5 Adjust the display intensity refer to figure 2 1 LCD DISPLAY OK FLASH OK DTMF OK I...

Page 13: ...git Master Code 0000 is default master code 2 The screen will show as below if the master code is valid Long beep if the master code is invalid need key to unlock the system then use the second method...

Page 14: ...tion code 00 then press 2 Enter new 4 digit master code then press 01 ADDING NEW TENANT DIRECTORY Each tenant must have unique directory Directory can be set 2 4 digit See function code 06 p17 Must be...

Page 15: ...eypad Function and Layout page 14 Press after entering last letter The screen will show 4 Enter telephone number up to 11 digit then press Enter the Name _ _ _ _ _ _ _ _ _ _ _ _ _ PH _ _ _ _ _ _ _ _ _...

Page 16: ...Y 1 00 close 01 99 open 01 98 hours timer 99 open for indefinite time Must be in programming mode see Two ways to Log on to programming mode on page 13 1 Enter function code 05 then press 2 Enter 01 9...

Page 17: ...13 1 Enter function code 10 then press 1st segment 2 Change the welcome screen see Keypad Function and Layout page 14 3 Press after entering the last letter on 1st segment 2nd segment 4 Press after en...

Page 18: ...0 Must be in programming mode see Two ways to Log on to programming mode on page 13 1 Enter function code 51 then press 2 Press 0 dedicated phone line or 1 no phone bill then press 70 TALK TIME 010 18...

Page 19: ...on with the person at the system Must be in programming mode see Two ways to Log on to programming mode on page 13 1 Enter function code 74 then press 2 Press 1 enable or 0 disable then press 75 KEYPA...

Page 20: ...Must be in programming mode see Two ways to Log on to programming mode on page 13 1 Enter function code 78 then press the display will show as an example shown 2 Press 3 scroll A Z 6 scroll Z A 3 Pre...

Page 21: ...he voice mail or extension number using the system s keypad E How to extend talk time Talk time is set using function code 70 10 180 seconds see p18 1 Establish a communication 2 Warning beep will be...

Page 22: ...rease or clockwise to decrease I How to increase or decrease the speaker s volume 1 Locate the speaker s volume adjustment see figure 2 1 p11 2 Turn counter clockwise to increase or clockwise to decre...

Page 23: ...he speaker and microphone connection check for broken wires 3 Disconnect the microphone and speaker connector then check the speaker s impedance must read between 18 24 ohms DISPLAY PROBLEMS Display s...

Page 24: ...phone line 1 Ground or remove the ground 2 Power the board outside the cabinet 3 Install a DSL filter 4 Install RF filter DOOR OR GATE PROBLEMS Remote access 9 does not provide access to visitor 1 Re...

Page 25: ...vices you can connect to your telephone line your telephone company will provide you upon request In the unlikely event your AeGIS system develops a problem IMMEDIATELY DISCONNECT IT FROM YOUR TELEPHO...

Page 26: ...AeGIS 7000P Page 26...

Reviews: