file:///C|/PACH-CO.COM-2018/online_manual/aegis7000s.htm[6/13/2019 7:18:06 AM]
AeGIS 7000S SERIES
3. 1st segment, enter the characters then press # see
Chapter 3
for keypad layout
4. 2nd segment, enter the characters then press # see
Chapter 3
for keypad layout
5. 3rd segment, enter the characters then pres # see
Chapter 3
for keypad layout
CHAPTER
5
Operations
5.1 Call from the System
1.
Direct Call
: press # then directory code, see
function code 19
2.
Scrolling
: press 3 or 6 to scroll name then press # to call the selected name
5.2 Opening Door Remotely
Relay 1 (door 1), press 9
Relay 2 (door 2), press 8
5.3 Opening Door Using Access Code, Temporary Code, and Special Code
Access code Standard Operation is keyless entry code to open the door and door will be closed automatically, see
function code 06
Temporary Code is used for limited number of times, maximum 10 times then the code will be expired, see
function code 33
Special Code is used to unlock hold door and then use same code to lock the door, see
function code 34
Press
*
(display will stop scrolling) then press the 4, 5, 6, 7 or 8 digit access code as programmed on
Function Code 09
5.4 Opening Door Using Card, Temporary Card, and Special Card
The AeGIS 7000S Series has built-in 26-Bit Wiegand Port. It is compatible with any 26 Bit Reader.
Card Standard Operation is used to open the door and door will be closed automatically, see
function code 10
Temporary Card is used for limited of times, maximum 10 times then the card will be expired, see
function code 35
Special Card is used to unlock hold door and then use same card to lock the door, see
function code 36
Pach and Company UFOB, UCLAM and UISO ONLY work on the UWCR.
5.5 Extending Talk Time
The talk time timer is set on
function code 27
. The warning beep will be heard one minute before the talk time is expired. It can be extended more another full cycle by
pressing #
5.6 Call the System from Remote Location
1.
The system must be install in
Intercom and Call Forwarding Mode Wiring Diagram
or
Call Forwarding Mode wiring Diagram
2.
Function code 38
must be
set at least for 1 ring
3.
Function code 39
must be set to 1
4. You must have the system phone number
5. Call the system phone number if the system answered, short beep will be heard.
Summary of Contents for 7000SC