background image

AeGIS 7000S SERIES 

file:///C|/PACH-CO.COM-2018/online_manual/aegis7000s.htm[6/13/2019 7:18:06 AM] 

 

 

 

Function Code 08: Clear All Access Codes

 

Function Code 09: Access Code Digit

 

Function Code 10: Add New Card or Transmitter 
Function Code 11: Delete Card or Transmitter 
Function Code 12: Clear All Cards and Transmitters 
Function Code 13: Set Time

 

Function Code 14: Set Date

 

 

 

Call from the System

 

Opening Door Remotely

 

Opening Door Using Access Code, Temporary Code and Special Code 
Opening Door Using Card, Temporary Card, and Special Card 
Extending Talk Time

 

Call the System from Remote Location

 

 

 

 
 

 

 
 

 
 

LIMITATIONS OF LIABILITY

 

 

This manual is subject to change without notice. 

 

Pach and Company is not liable for any errors that might occur from use of this document, nor is any commitment to update the information herein implied. 

 

Pach and Company does not assume any liability for any damages, which may arise in installation or use of the AeGIS 7000S Series Pach and Company does not 
assume liability for any incompatibility between the AeGIS 7000S Series and users devices. 

 

Pach & Company reserves the right to make changes without prior notice to any products in order to improve reliability, function or design. 

 

 

 
 

PRODUCTS LIMITED WARRANTY

 

 

 

New Products warranty (24 months)

 

 

Products are warranted to be free of defects in material or workmanship for a period of 

 24 months 

from the date of purchase. 

 

Products must be purchased from authorized distributors and install by qualified installers. 

 

Warranty can only be honored to the authorized distributors or qualified installers. 

 

RMA must be issued by Pach and Company Technical Department for any replacement part(s). 

 

Replacement part(s) will be shipped via 

 UPS Ground 

within the 24 months warranty. The defective part(s) must be returned to Pach and Company within 15 

days. 

 

Pach and Company 

 is not responsible for time, travel, and/or labor costs of any distributor and/or dealer-installer

, including but not limited to, any expenses 

to install, uninstall or reinstall hardware/software/firmware related to warranty issues, product enhancements, or product failures. 

 

Wiegand Card, Keyfob  and Transmitter  Warranty  (90 days)

 

 

Warranted to be free of defects in material and workmanship for a period of 90 days from the date of purchase. 

 

RMA must be issued by Pach and Company Technical Department for replacement. 

 

Replacement part(s) will be shipped via 

 UPS Ground 

within the 24 months warranty. The defective part(s) must be returned to Pach and Company within 15 

days. 

 

Pach and Company 

 is not responsible for time, travel, and/or labor costs of any distributor and/or dealer-installer

, including but not limited to, any expenses 

to install, uninstall or reinstall hardware/software/firmware related to warranty issues, product enhancements, or product failures. 

 

 

 

Replacement Parts Warranty (6 months)

 

 

Warranted to be free of defects in material and workmanship for a period of 

 6 months 

from the date of purchase. 

 

RMA must be issued by Pach and Company Technical Department for replacement. 

 

Replacement part(s) will be shipped via 

 UPS Ground 

within the 6 months warranty. The defective part(s) must be returned to Pach and Company within 15 days. 

 

Pach and Company 

 is not responsible for time, travel, and/or labor costs of any distributor and/or dealer-installer

, including but not limited to, any expenses 

to install, uninstall or reinstall hardware/software/firmware related to warranty issues, product enhancements, or product failures. 

 

 

CHAPTER 1

 

Getting Started

 

Summary of Contents for 7000SC

Page 1: ...ing Event Recording Function Code 16 Auto Unlock Schedule AUS Function Code 17 Time Zone TMZ Function Code 18 Holiday Zone HLD Function Code 19 Directory Digit Function Code 20 AUXIN1 Function Code 21...

Page 2: ...cement part s Replacement part s will be shipped via UPS Ground within the 24 months warranty The defective part s must be returned to Pach and Company within 15 days Pach and Company is not responsib...

Page 3: ...o eight slaves Two on board relays Two Auxiliary inputs Operating environment 10 F 140 F Relative Humidity 0 95 non condensing Double 3 4 knock out on the back and bottom panel Features 20 programmabl...

Page 4: ...AeGIS 7000S SERIES file C PACH CO COM 2018 online_manual aegis7000s htm 6 13 2019 7 18 06 AM 2 1 General Wiring Diagram...

Page 5: ...8...

Page 6: ...AeGIS 7000S SERIES file C PACH CO COM 2018 online_manual aegis7000s htm 6 13 2019 7 18 06 AM Figure 2 1 General Wiring Diagram 2 2 Power Wiring Diagram...

Page 7: ...C PACH CO COM 2018 online_manual aegis7000s htm 6 13 2019 7 18 06 AM Figure 2 2 Power Wiring Diagram 2 3 VOIP Wiring Diagram In rare occasion compatibility issue may occur between the AeGIS 7000S Ser...

Page 8: ...AeGIS 7000S SERIES file C PACH CO COM 2018 online_manual aegis7000s htm 6 13 2019 7 18 06 AM Figure 2 3 Wiring Diagram 2 4 Door Strike Wiring Diagram...

Page 9: ...AeGIS 7000S SERIES file C PACH CO COM 2018 online_manual aegis7000s htm 6 13 2019 7 18 06 AM Figure 2 4 Door Strike Wiring Diagram 2 5 Input Device and Door Sensor Wiring Diagram...

Page 10: ...AeGIS 7000S SERIES file C PACH CO COM 2018 online_manual aegis7000s htm 6 13 2019 7 18 06 AM Figure 2 5 Input Device and Door Sensor Wiring Diagram 2 6 Satellite System Wiring Diagram...

Page 11: ...gure 2 1 number 10 The LCD will go into a cycling mode as below LCD Display OK Flash OK RTC OK DTMF OK INIT START INIT COMPLTE SCROLLING CHAPTER 3 Keypad Correlation Table The QR5 buttons are lighted...

Page 12: ...efault the directory digit is set to 3 but it can be changed to 3 or 4 digit See function code 19 1 Log in to programming 2 Enter 01 then 3 Enter directory number 0 9 directory is in single digit and...

Page 13: ...16 digit then press or press without entering anything to keep the existing number Return to step 3 to edit another tenant directory Function Code 03 Delete Tenant Directory 1 Log in to programming 2...

Page 14: ...g 2 Enter 06 then 3 Enter the access code 4 8 digit see function code 09 then press see Chapter 3 for keypad layout 4 Enter name up to 16 characters then press 5 Enter door 1 or 2 or 3 for both then p...

Page 15: ...de then press or to cancel Function Code 09 Access Code Digit 1 Log in to programming 2 Enter 09 then 3 Enter 4 5 6 7 or 8 default setting is 4 digit then press Function Code 10 Add New Card 1 Log in...

Page 16: ...nd return to step 3 to add program another card 1 add additional time zone then press and return to step 6 exit programming Function Code 11 Delete Card 1 Log in to programming 2 Enter 11 then 3 Prese...

Page 17: ...nter 0 Sunday 1 Monday 2 Tuesday 3 Wednesday 4 Thursday 5 Friday 6 Saturday then press 5 Enter 0 NO Daylight Saving Zone Hawaii Indiana and Arizona 1 Daylight Saving Zone then press Function Code 15 I...

Page 18: ...ress or 1 Add AUS then press 5 Enter open time in military then press 6 Enter close time in military then press 7 Enter 0 Sunday 1 Monday 2 Tuesday 3 Wednesday 4 Thursday 5 Friday 6 Saturday then pres...

Page 19: ...Zone TMZ and Auto Unlock Schedule AUS during the holidays Up to 20 Holiday Zone can be programmed 1 Log in to programming 2 Enter 18 then 3 Enter 01 20 then press 4 Enter 0 Delete the existing holida...

Page 20: ...is used for input device such as postal lock infrared sensor exit button etc AUXIN2 is associated with relay 2 1 Log in to programming 2 Enter 21 then 3 Enter 0 disable default setting 1 Enable contro...

Page 21: ...stem for 60 seconds with no beep 3 call directory 0 9 then press Function Code 25 Keypad Beep Turn the keypad press beep On or Off 1 Log in to programming 2 Enter 25 then 3 Enter 0 off 1 On default th...

Page 22: ...mporary Code The code will expire after a certain amount of used 1 10 times in the programming Up to 10 temporary codes can be programmed 1 Log in to programming 2 Enter 33 then 3 Enter 0 delete exist...

Page 23: ...press and return to step 8 exit programming Function Code 34 Special Code Unlock hold open hold and use same code to lock close door or gate Up to 10 special codes can be programmed 1 Log in to progr...

Page 24: ...amount of used 1 10 times in the programming Up to 10 temporary fobs or cards can be programmed 1 Log in to programming 2 Enter 35 then 3 Enter 0 delete 1 add then press 4 Enter card 01 10 then press...

Page 25: ...er code 01 10 then press 5 Enter 4 8 digit code see digit setting on function code 09 see Chapter 3 for keypad layout 6 Present the card or fob in front of the black window the system will register th...

Page 26: ...ng 9 will remotely trigger relay 1 door 1 The number can be changed by selecting 1 9 to trigger relay 1 door 1 Note by default remote access for relay 2 is set to 8 see function code 41 If you set rel...

Page 27: ...the days you can create Do Not Disturb Time Zone For example 22 00 06 00 Monday Sunday Up to 10 Do Not Disturb Time Zones ca be programmed 1 Log in to programming 2 Enter 43 then 3 Enter 0 9 then pres...

Page 28: ...onday 2 Tuesday 3 Wednesday 4 Thursday 5 Friday 6 Saturday then press Return to step 3 to program more time zone Function Code 45 Relay 1 and 2 Unlock Timer Relay 1 and 2 can be unlock using count dow...

Page 29: ...ime for the PBX system to access dial tone generally 2 3 second delay is plenty of time then press Function Code 49 Edit Existing Access Code Temporary Code and Special Code 1 Log in to programming 2...

Page 30: ...play will stop scrolling then press the 4 5 6 7 or 8 digit access code as programmed on Function Code 09 5 4 Opening Door Using Card Temporary Card and Special Card The AeGIS 7000S Series has built in...

Page 31: ...6 13 2019 7 18 06 AM AeGIS 7000S SERIES 6 Press then 4 digit Master code default is 0000 short beep will be heard if master code is accepted 7 Press to establish two ways communication 8 Press 9 to r...

Reviews: