a) Press and release the Scroll Up
Key to increase Tip Temperature in increments. Press
and release the Scroll Down
Key to decrease Tip Temperature. Observe the display as
the Set Temperature increases in increments of 1°.
NOTE:
If a Password has been previously programmed into the system, "EP0" will appear
on the LED Display at this point. When this message appears, the operator must
enter the correct 5 key Password before adjusting the temperature. Refer to
“Password” in the “Operation” portion of this manual.
b) Adjust the temperature by pressing and holding Scroll Up
Key. Observe the display as
the Set Temperature increases first in increments of 1° and then in increments of 10°.
Release the key.
c) Using the Scroll Keys, adjust the temperature to any standard operating temperature used by
your company.
NOTE:
The Set Temperature can only be within the set temperature limits. If a limit (upper
or lower) is reached, the lower limit would display “OFF”; the upper limit would not
allow the Set Temperature to exceed that limit. Temperature limits can be adjusted
in the Set-Up Mode.
6. Press the Program Key (
). The system will now return to normal operation.
7. Observe the Digital Readout as the temperature stabilizes at the desired Set Tip Temperature.
8. Manually force the system into Temperature Setback in the following manner:
a) Press and hold the Scroll Down
Key and the Scroll Up
Key.
b) Release both keys.
9. The system is now in Temperature Setback. Observe the flashing of the LED Display and the
decreasing of the tip temperature. Allow time for the temperature to stabilize at 177°C (350°F).
NOTE:
If Auto Off has been enabled (turned on in Set-Up Mode), the system will enter Auto
Off (temperature Off and LED Display flashing "Off") after the preset time of handpiece
inactivity. Auto Off can be exited by pressing any key.
10. Manually force the system out of Temperature Setback in either of the following manners:
a) Press and release a Key (either of the 3 keys). This is the preferred method.
b) Wipe the hot handpiece tip on a wet sponge to lower the tip temperature.
c) Turn the Power Switch Off ("0") and then back on ("I").
11. The system is now in normal operation. Observe the LED Display as the tip temperature
increases to the Set Temperature. Allow time for the temperature to stabilize at the Set
Temperature.
NOTE:
Read the “Operation” and “Set-Up Mode” sections of this manual to utilize the full
capabilities of the system. This is especially important when using large soldering
tips or other SensaTemp handpieces.