PACE factory specifications) or the temperature setting normally used by the operator.  If 
the temperature displayed on temperature meter is within ±15°C (27°F), perform steps 4 
thru 6 to obtain a precise reading.  If the temperature is off by more than ±15°C, the 
handpiece may require maintenance.  Recheck the temperature using a 
second handpiece. 

 
4.  Carefully lock the Variable Temperature Control in position by tightening the 

inner set screw (closest to front panel). 

 

5. 

Loosen the outer set screw on the Variable Temperature Control knob (furthest 
from front panel) using the Temp. Locking Key (hex key) supplied with the 
system.  Position the knob with the pointer aligned to match the temperature 
indicated on the temperature meter.  Secure the knob in position by tightening 
the outer set screw.  Loosen the inner set screw to unlock the Variable 
Temperature control if adjustment of operating tip temperature is desired.

   

 

 

Vacuum Pump Operation 

 

The PACE ST 125 contains two different vacuum pumps.   

 

1. HiFlo 

Pump 

 

a)   To activate, depress the handpiece activation button. 
 
b)  Optional Foot Pedal can be used to actuate the HiFlo pump via the rear TEKLINK 

socket. 

 

2. LoFlo 

Pump 

 

 

a)  This pump is activated by the front Illuminated LoFlo Pump Switch. 
 
b)  Used for the TJ-70/80 and PV-65 Pik Vac Wand. 

 

CAUTION:  

Ensure that only one air hose is connected to the 

VACUUM

 or controllable 

PRESSURE

 

port at one time.  Attachment to both ports simultaneously will cause deterioration in 
performance. 

 
Handpiece Vacuum/Pressure 

 

To set up your Sodr-X-Tractor air hose connection, perform the following steps: 
 

1.   Air Hose To Handpiece Connection: 
 

a)   Attach one end of a 137cm (54 inch) length of air hose to the metal 

tube in the back of the handpiece.

  

 

b)

  

If you have a PACE system incorporating only one handpiece, attach 

the air hose to the power cable using the supplied Hose Clamps.  
Space them evenly along the length of the power cable starting at a 
point 6 inches from the ends of the handpiece. 

 
c)   If you have a PACE system incorporating 2 or more air handpieces, 

you may wish to leave the air hose assembly unattached to allow a quick change to any 
air handpiece being used. 

 

2.   Prepare a VisiFilter in the following manner: 

©2004 PACE Inc., Annapolis Junction, Maryland 

Page 9 of 13 

All Rights Reserved 

Summary of Contents for SODRTEK ST 125

Page 1: ...Operation and Maintenance Manual for the SODRTEK ST 125 Soldering System P N 5050 0534 ...

Page 2: ...ration 7 Tip Offset 7 Variable Temperature Control 8 Temperature Dial Lock 8 LED Operation 8 Temperature Dial Adjustment 8 Vacuum Pump Operation 9 Handpiece Vacuum Pressure 9 Corrective Maintenance 10 Power Source 10 Handpieces 10 Packing List 11 Spare Parts 11 Service 11 SODRTEK by PACE LIMITED WARRANTY STATEMENT 12 Contact Information 13 2004 PACE Inc Annapolis Junction Maryland Page 2 of 13 All...

Page 3: ... 97 127 VAC 50 60Hz 90 Watts maximum at 115 VAC 60Hz ST 125E Operates on 197 253 VAC 50 60Hz 80 Watts maximum at 230 VAC 50Hz Temperature Specifications Handpieces Tip Temperature Range 204 to 455 C 400 to 850 F nominal Temperature Stability 1 1 C 2 F at idle from set tip temp NOTE Actual minimum and maximum Operating Tip Temperatures may vary depending on Handpiece Tip Selection and application V...

Page 4: ...HiFlo Vacuum Port Power Switch Front Panel LED Temperature Selection Dial Illuminated LoFlo Pump Switch LoFlo Pressure Port Earth Ground Receptacle AC Power Receptacle Fuse Holder TEKLINK Receptacle Fuse 2004 PACE Inc Annapolis Junction Maryland Page 4 of 13 All Rights Reserved ...

Page 5: ...r off DO NOT touch either the heater or the tip Severe burns may result 4 PACE Tip Tool Stands and handpiece cubbies are designed specifically for use with the associated handpiece and houses it in a manner that protects the user from accidental burns Always store the handpiece in its holder Be sure to place the handpiece in its holder after use and allow for cooling before storing 5 Always use PA...

Page 6: ... and tighten Thumb Nuts 2 Place the handpiece into its Tip Tool Stand Handpiece Connection Connect the handpiece connector plug into the Power Receptacle in the following manner 1 Align guide on connector with slot on power receptacle 2 Insert connector into power receptacle 3 Turn the connector housing clockwise to lock in place TEKLINK The TEKLINK receptacle located on the back panel of the powe...

Page 7: ...h in the OFF 0 position 2 Ensure that the handpiece is connected to the power source If a plastic cap is present on the heater assembly remove it and discard The cap is used for shipping purposes only Place the handpiece in the Tip Tool Stand 3 Turn on the power source 4 Turn the Temperature dial to 315 C 600 F for 10 minutes 5 Next increase the temperature to 427 C 800 F for 15 minutes 6 Turn off...

Page 8: ...ariable Temperature Control has been reached Power to the handpiece is cycling Off and On to maintain set temperature LED Off No power is being delivered to the handpiece heater This condition is evident for a short period of time when set temperature is reached and stabilizing or if the Variable Temperature Control setting is decreased If the LED never illuminates check for a faulty handpiece see...

Page 9: ...handpiece activation button b Optional Foot Pedal can be used to actuate the HiFlo pump via the rear TEKLINK socket 2 LoFlo Pump a This pump is activated by the front Illuminated LoFlo Pump Switch b Used for the TJ 70 80 and PV 65 Pik Vac Wand CAUTION Ensure that only one air hose is connected to the VACUUM or controllable PRESSURE port at one time Attachment to both ports simultaneously will caus...

Page 10: ... end of a 1 inch 2 5cm length of air hose with an installed female quick connect hose mount fitting P N 1259 0086 to the FLOW IN side of the VisiFilter Assembly c The 137cm 54 inch length of air hose can now be easily moved between the VisiFilter Assembly and the Controllable Pressure Port The VisiFilter assembly remains connected to the Vacuum Port 4 Additional fittings may also be added to the h...

Page 11: ... 0093 0 1 5 Hex Key 050 1100 0237 1 1 6 Operations Manual CD CD5050 0459 1 1 Spare Parts Item Description PACE Part Number Fuse 1 25 Amp 250 V Time Lag ST 125 1159 0251 P5 1 Fuse 0 63 Amp 250 V Time Lag ST 125E 1159 0252 P5 2 Tip Temperature Selection Chart 5050 0251 3 TEKLINK Cable 1332 0252 P1 4 TEKLINK Remote Box 3008 0218 P1 Service Please contact PACE or your local distributor for service and...

Page 12: ...tion approved by it at no charge to user or provide parts without charge for installation by the user in the field at user s expense and risk User will be responsible for all costs of shipping equipment to Seller or other location for warranty service EXCEPT FOR THE REMEDY ABOVE DESCRIBED UNLESS OTHERWISE REQUIRED BY APPLICABLE LAW SELLER WILL HAVE NO OTHER OBLIGATION WITH REGARD TO ANY BREACH OF ...

Page 13: ...orporated Annapolis Junction Maryland U S A ARM EVAC FLO D SODR MINIWAVE PACE SENSATEMP SNAP VAC SODRTEK SODR X TRACTOR THERMOFLO THERMOJET THERMOTWEEZ VISIFILTER THERMO DRIVE and TOOLNET PACE products meet or exceed all applicable military and civilian EOS ESD temperature stability and other specifications including MIL STD 2000 ANSI JSTD 001 IPC7711 and IPC A 610 www paceworldwide com PACE USA P...