background image

MTS Systems Operation Manual  

©2004 PACE Inc., Annapolis Junction, Maryland 

Page 7 of 11 

All Rights Reserved 

 

HiFlo Vacuum Port 

LoFlo Vacuum Port 

If  the  power  is  turned  on  while  a  Power  Module  is  not installed, or  if  the  Power  Module  is  removed 
during operation, the system will turn itself off and the LED indicator light on the front panel will turn 
red.   
To  operate  the  unit,  please  make  sure  the  set-up  procedure  has  been  followed.    Then  follow  the 
procedure below. 
 

1.  If using the TD-100 handpiece, make sure the desired Tip Cartridge is installed.  If using the 

MT-100, make sure the desired pair of tips are installed.   

2.  Install the desired Power Module into the Power Port on the front of the unit that corresponds 

to the appropriate handpiece channel. 

3.  The LED indicator will turn amber while the tip(s) is (are) heating to the desired performance 

level. 

4.  Once the tip has reached the desired level, the LED indicator will turn green and the system 

is ready to use. 

 

To  preserve  tip  life  and  save  energy,  MTS  systems  come  standard  with  Auto-
Setback  and  Auto-Off  Features.    These  are  pre-
programmed  for  30  minute  Auto-Setback  and  30  minute 
Auto-Off, which can be turned off by the switch on the back 
of the unit.  If the handpiece channel has not been used for 
30  minutes,  the  channel  will  enter  setback  mode,  the 
performance  level  will  be  adjusted  to 3.5  and  the  LED  will 
blink  amber.    To  exit  Setback  mode,  place  the  tip  in  the 
sponge  to  load  it  thermally  or  turn  the  Power  Switch  OFF 
(“0”) and then back ON (“l”).  After an additional 30 minute period of inactivity the channel will turn off 
and  the  LED  will  turn  off.    To  exit  Auto-Off  mode,  cycle  the  system  power.    The  Setback/Auto-Off 
feature can be turned  off for each channel individually.   As received from the factory, this feature  is 
enabled.   

 

Vacuum Pump Operation 

 
The  PACE  MTS  300/350  contains  two  different  vacuum 
pumps.   
 

1.  HiFlo pump 

a)      To  activate,  depress  the  handpiece  activation 

button. 

b)  An Optional Foot Pedal can be used to actuate the 

HiFo pump via the rear panel foot switch socket. 

 

2.  LoFlo Pump  

a)  This  pump  will  be  activated  by  a  front  panel 

mounted Illuminated LoFlo Pump Switch. 

b)  Used for the TJ-80 and PV-65 Pic Vac Wand. 
 

Setback/Auto-Off 
Switches 

 

AC Power 
Receptacle/Fuse 
Holder

 

 

HiFlo Pressure Port 

LoFlo Pressure Port 

Illuminated LoFlo Pump 
Switch 

MTS 350 Shown 

Summary of Contents for MTS 200

Page 1: ...VAC 8007 0414 MTS 200 SC System 230 VAC 8007 0415 MTS 200 SA System 115 VAC 8007 0412 MTS 200 SA System 230 VAC 8007 0413 MTS 300 System 115 VAC 8007 0418 B MTS 300 System 230 VAC 8007 0419 B MTS 350...

Page 2: ...n 4 Safety 5 System Set Up 5 Mounting Options 5 System Power Up 5 Handpieces 6 Handpiece Tip Tool Stands 6 Adjusting the Angle of the Cubby 6 Handpiece Connection 6 Operation of MTS Systems 6 Vacuum P...

Page 3: ...e FH channel the MTS 350 features 1 HC channel and 2 FH channels The system also comes standard with Auto Setback and Auto Off functions to preserve tip life Applicable Regulations MTS systems are ava...

Page 4: ...1 3 Amp 115 VAC 60 Hz Max OR 7 Amp 230 VAC 50 Hz Max Fuse 2 Amp SloBlo 115 V System 1 Amp TimeBlo 230 V System MTS 350 1 3 Amp 115 VAC 60 Hz Max OR 7 Amp 230 VAC 50 Hz Max Fuse 2 Amp SloBlo 115 V Syst...

Page 5: ...CE systems in a well ventilated area A fume extraction system such as those available from PACE are highly recommended to help protect personnel from solder flux fumes 6 Exercise proper precautions wh...

Page 6: ...ector and handpiece port on the system For example HC handpieces have the red connector and will only connect to red ports Likewise Fixed Heater handpieces have black connectors and can only be connec...

Page 7: ...Features These are pre programmed for 30 minute Auto Setback and 30 minute Auto Off which can be turned off by the switch on the back of the unit If the handpiece channel has not been used for 30 min...

Page 8: ...iFilter FLOW OUT side into the power source Vacuum Port 3 When using air pressure and or utilizing multiple air handpieces PACE recommends the use of the following set up procedure which utilizes addi...

Page 9: ...one of the same rated value Handpiece will not heat Defective Heater Change Tip Cartridge Power Source Malfunction Contact PACE Power Source Corrective Maintenance Packing Contents Description MTS 200...

Page 10: ...WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE Seller will at its option repair or replace any defective products at its facility or other location approved by it at no charge to user...

Page 11: ...BRITE AUTO OFF and TEKLINK The following are registered trademarks and or service marks of PACE Incorporated Annapolis Junction Maryland U S A ARM EVAC FLO D SODR MINIWAVE PACE SENSATEMP SNAP VAC SOD...