background image

MTS Systems Operation Manual  

©2004 PACE Inc., Annapolis Junction, Maryland 

Page 4 of 11 

All Rights Reserved 

 

Electrical Specifications 

 
MTS 200 

1.3 Amp 115 VAC, 60 Hz Max OR .7 Amp, 230 VAC, 50 Hz Max 
Fuse:  2 Amp, SloBlo 115 V System - 1 Amp TimeBlo, 230 V System 
 

MTS 300 

1.3 Amp 115 VAC, 60 Hz Max OR .7 Amp, 230 VAC, 50 Hz Max 
Fuse:  2 Amp, SloBlo 115 V System - 1 Amp TimeBlo, 230 V System 
 

MTS-350 

1.3 Amp 115 VAC, 60 Hz Max OR .7 Amp, 230 VAC, 50 Hz Max 
Fuse:  2 Amp, SloBlo 115 V System - 1 Amp TimeBlo, 230 V System 

 

Parts Identification

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Power Switch 

Power Module Ports 

Power Receptacles 

LED Indicators
 

 

MTS 200 Shown 

Setback/Auto-
Off Switches 

 

 

 

Earth Ground Receptacle  

 

AC Power Receptacle/Fuse 

Holder

 

 

Auto Snap-Vac Port 

Controllable Pressure 
Port 

Summary of Contents for MTS 200

Page 1: ...VAC 8007 0414 MTS 200 SC System 230 VAC 8007 0415 MTS 200 SA System 115 VAC 8007 0412 MTS 200 SA System 230 VAC 8007 0413 MTS 300 System 115 VAC 8007 0418 B MTS 300 System 230 VAC 8007 0419 B MTS 350...

Page 2: ...n 4 Safety 5 System Set Up 5 Mounting Options 5 System Power Up 5 Handpieces 6 Handpiece Tip Tool Stands 6 Adjusting the Angle of the Cubby 6 Handpiece Connection 6 Operation of MTS Systems 6 Vacuum P...

Page 3: ...e FH channel the MTS 350 features 1 HC channel and 2 FH channels The system also comes standard with Auto Setback and Auto Off functions to preserve tip life Applicable Regulations MTS systems are ava...

Page 4: ...1 3 Amp 115 VAC 60 Hz Max OR 7 Amp 230 VAC 50 Hz Max Fuse 2 Amp SloBlo 115 V System 1 Amp TimeBlo 230 V System MTS 350 1 3 Amp 115 VAC 60 Hz Max OR 7 Amp 230 VAC 50 Hz Max Fuse 2 Amp SloBlo 115 V Syst...

Page 5: ...CE systems in a well ventilated area A fume extraction system such as those available from PACE are highly recommended to help protect personnel from solder flux fumes 6 Exercise proper precautions wh...

Page 6: ...ector and handpiece port on the system For example HC handpieces have the red connector and will only connect to red ports Likewise Fixed Heater handpieces have black connectors and can only be connec...

Page 7: ...Features These are pre programmed for 30 minute Auto Setback and 30 minute Auto Off which can be turned off by the switch on the back of the unit If the handpiece channel has not been used for 30 min...

Page 8: ...iFilter FLOW OUT side into the power source Vacuum Port 3 When using air pressure and or utilizing multiple air handpieces PACE recommends the use of the following set up procedure which utilizes addi...

Page 9: ...one of the same rated value Handpiece will not heat Defective Heater Change Tip Cartridge Power Source Malfunction Contact PACE Power Source Corrective Maintenance Packing Contents Description MTS 200...

Page 10: ...WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE Seller will at its option repair or replace any defective products at its facility or other location approved by it at no charge to user...

Page 11: ...BRITE AUTO OFF and TEKLINK The following are registered trademarks and or service marks of PACE Incorporated Annapolis Junction Maryland U S A ARM EVAC FLO D SODR MINIWAVE PACE SENSATEMP SNAP VAC SOD...