background image

©2018 PACE Inc., Vass, North Carolina, All Rights Reserved                                                           Page 1 
 

 

General Information 

 

Introduction 

 
Thank you for purchasing the ADS200 Soldering System. This manual will provide you with the information 
necessary to properly set up, operate, and maintain your system. Please read this manual thoroughly before 
using the system. 
 
The systems featured in this guide are available in either 115 VAC or 230 VAC versions. All of these models 
incorporate AccuDrive® technology. The 230 VAC version systems bear the CE Conformity Marking, which 
assures the user that it conforms to EMC 89/336/EEC. All models featured in this manual are lead free 
compatible and comply with RoHS and WEEE directives. 
 
These systems all meet or exceed the ANSI requirements for Soldered Electrical and Electronic Assemblies, J-
STD-001.  Additionally they meet or exceed the requirements for electrostatic discharge set forth by ANSI/ESD 
S20.20.  Compliance with both of these standards is ensured by testing up to 50 MHz using the methodology 
described in ANSI/ESD S13.1 2015. 
 

Specifications 

 

For 120V systems, 97-127 VAC at 50/60 Hz 

Input Power Requirements 

For 230V systems, 197-253 VAC at 50/60 Hz 

Output Power 

120 Watts Maximum Output 

Dimensions 

104 mm 

H

 x 130 mm 

W

 x 152 mm 

4.1” 

x 5.1” 

X 6” 

D

 

Weight 

2.3 kg (5 lbs) 

RoHS Compliant 

Yes 

Control Technology 

AccuDrive® 

Tip-to-Ground Resistance 

2 Ohms or less 

Temperature Accuracy 

Meets or Exceeds ANSI/J-STD-001 

Temperature Range 

177-454°C (350-850°F) 

Tips 

AccuDrive® Blue Series Tip-Heater Cartridges 

Soldering Iron 

TD-200 AccuDrive® 

Standard Tool Stand 

Can hold up to 7 tips. Includes sponge in a stay-

moist well and brass wool tip cleaner. 

Instant SetBack Tool Stand 

Included with 8007-0579 and 8007-0581.  

Available separately as item 6019-0089-P1 

 

Refer to the Setup and Operation section page 5 for the feature settings set as default by the factory.  There is 
not a factory reset option for feature settings, changes must be made manually. 
 

Temperature Specifications 

 
AccuDrive® Blue Series Tip-Heater Cartridges connected to the ADS200 have a Tip Temperature Range of 177 
to 454°C (350 to 850°F).  
Digital Readout Resolution: ±5° (°C or °F) 
Tip Temperature Stability: ±1.1°C (2°F) when idle.  
Temperature Accuracy: Meets or exceeds ANSI/J-STD-001 
 

EOS/ESD Specifications 

 

Tip-To-Ground Resistance: Less than 2 ohms. 
AC Leakage: Less than 2 Millivolts RMS from 50 Hz to 100 MHz.  
Transient Level: Less than 500 mV peak, out to 100 MHz. 

Summary of Contents for ADS200

Page 1: ...0589 Rev Date 4 1232018 This manual applies to Model Firmware Revision Required Power Part Number ADS200 w Standard Tool Stand 1 2 120 VAC 8007 0578 ADS200 w ISB Tool Stand 1 2 120 VAC 8007 0579 ADS20...

Page 2: ...LED Display Normal Operation 5 Digital Display Temperature Adjust Mode 5 Default Factory Settings 5 Customizing Your System 6 Entering Set Up Mode 6 Password 6 Temperature Scale 6 Temperature Limits 7...

Page 3: ...uirements For 230V systems 197 253 VAC at 50 60 Hz Output Power 120 Watts Maximum Output Dimensions 104 mm H x 130 mm W x 152 mm D 4 1 H x 5 1 W X 6 D Weight 2 3 kg 5 lbs RoHS Compliant Yes Control Te...

Page 4: ...to cool before storing 4 Always use PACE systems in a well ventilated area Fume extraction systems such as those available from PACE are highly recommended to help protect personnel from solder flux...

Page 5: ...the Power Receptacle in the following manner 1 Align guide on connector with slot on power receptacle 2 Insert connector into power receptacle 3 Turn the connector housing clockwise to lock in place...

Page 6: ...which will be 260 460 C 500 800 F as set at the factory If the upper limit has been reached the display will read HiL if the Lo limit is reached the display will read OFF Temperature limits can be adj...

Page 7: ...ing when adjusting the desired Set Tip Temperature 1 The Set Tip Temperature 2 HiL High Temperature Limit when adjusting the set tip temperature and the maximum allowable temperature is exceeded Refer...

Page 8: ...version is displayed Password 3 The LED Display will show the version of the microprocessor and change to read P or EP If the display reads EP a Password has been stored in system memory The password...

Page 9: ...hese limits control how high or low the Set Temperature can be adjusted to during normal operation Automatic Setback Timer What is Temperature Setback To preserve tip life and save energy the system c...

Page 10: ...lue between 015 and 240 representing seconds This indicates how long of a delay before the system goes into SetBack mode when the handpiece is placed into the Instant SetBack Tool Stand if one is atta...

Page 11: ...ng Set Up Mode 13 The LED Display now reads End The Set Up Mode procedure is now complete Choose one of the following steps Press and release the Scroll Up Key to save the changes exit the Set Up Menu...

Page 12: ...e fuse located in the AC Receptacle Fuse Holder with one of the same rated value Defective Tip HeaterCartridge Refer to the appropriate handpiece manual Handpiece will not heat Power Source Malfunctio...

Page 13: ...est widest tip with the maximum contact surface area with which you can safely access the work Standard Tips For delicate micro soldering to challenging high thermal mass applications Ultra Performanc...

Page 14: ...ng equipment to Seller or other location for warranty service EXCEPT FOR THE REMEDY ABOVE DESCRIBED UNLESS OTHERWISE REQUIRED BY APPLICABLE LAW SELLER WILL HAVE NO OTHER OBLIGATION WITH REGARD TO ANY...

Reviews: