background image

 Output

 

AC120V 60Hz

 Power Consumption

 

600W (Large plate)

 400W (Small plate)

 Temperature Range

 0-500

F

 Temperature Stability

 ±10

F

 Dimensions

Controller ………………………....1 Thermocouple ………………….1

   

Preheat plate

L or S

…………….1 Instruction manual …………….1

    

Power coed ……………………....1

 Size of plate

 178×178mm (Large plate)   (7.0

×

7.0 in)

 102×178mm (Small plate)   (4.0

×

7.0 in)

 Weight (Without cord)

 2.5kg (Large plate)    (5.5 lbs.)
 2.0kg (Small plate)     (3.7 lbs.)
 1.0kg (Controller)       (2.2 lbs.)

Controller
To use the controller to configure the preheat plate for use as follow.

Warnings and cautions are placed at critical points in this manual to 
direct the operator's attention to significant items. They are defined
as follows.

 

WARNING

Failure to comply with a WARNING may result in
serious injury or death.

 

CAUTION

Failure to comply with a CAUTION may result in 
injury to the operator, or damage to the items 

1

Turn the power switch ON.

involved.

2

Setting temperature is displayed as Set Variable(SV).

    Plate temperature is displayed as Process Variable(PV).
    The plate temperature rises to the setting temperature.
 3

When changing the setting temperature,

     press the “

”button or “

”button to set the temperature.

4

Turn the power switch OFF after using.

*Toggle Switch
The controller has toggle switch to select between plate temperature 
control or T/C temperature control.

For T/C temperature control:
1

Insert thermocouple into thermocouple connector. Place the

    thermocouple end on a desired temprature measuring point or 
    the item to be heated by the plate.
2

Switch toggle switch to T/C mode.

3

Temperature reading of the thermocouple is displayed as Process

    

    Variable. Change the setting temperature as needed.

WARNINGS AND CAUTIONS

SPECIFICATIONS

OPERATION

PACKING LIST AND PART NAMES

  When the thermocouple is attached, the temperature of the plate
  will rise until the T/C reaches to the setting temperature.
  Ensure the T/C is properly attached and not left in open air or
  damage may result.

Power switch

PV

SV

Setting temperature

Plate temperature

Toggle
switch

Themocouple connector

 

CAUTION

Instruction Manual

Preheat plate

(Large plate)
(Small plate)
(Controller)

250(W)×79(H)×204(D)mm  (9.8×3.1×8.0 in)
175(W)×79(H)×204(D)mm  (6.9×3.1×8.0 in)
100(W)×66(H)×169(D)mm  (3.9×2.6×6.7 in)

 CAUTION

When power is ON, the plate surface may be as hot as 500

. To avoid

injury or damage to personnel and items in the work area, observe the
following

Do not touch the plate or place metal parts near the plate.

Do not allow the plate to come close to, or touch, flammable materials.

Inform others in the area that the unit is hot and should not be

 

 touched.

Turn the power off when not in use, or left unattended.

This product is not intended for use by persons (including children)

 

 with reduced physical, sensory or mental capabilities, or lack of

 

 experience  and knowledge, unless they have been given supervision

 

 or instruction concerning use of the product by a person responsible

 

 for their safety.

Children should be supervised to ensure that they do not play with the

 

 

product.

Do not use the product for applications other than Preheat plate.

Do not allow the product to become wet, or use it with wet hands.

Remove power and controller cords by holding the plug - not the cord.

While using the product, don't do anything which may cause bodily

 

 harm or physical damage.

Thank you for purchasing Preheat plate.

Please read this manual before operating the Preheat plate.

Keep this manual readily accessible for reference.

Reviews: