9. The LED Display now shows the stored Temperature Setback time as "S-X"
(x=0 thru 9). Time is shown as tens of minutes (e.g., "S-3" equals 30
minutes). A display of "S- 0" indicates that Setback is disabled. Choose one
of the following:
a) Press and release the Program Key (
) to keep the currently stored Temperature
Setback time.
b) Press and release the Scroll Up
Key to enable and/or increase the stored
Temperature Setback time. Press and release the Program Key to proceed to the
next step.
c) Press and release the Scroll Down
Key to decrease or disable the stored
Temperature Setback time. Press and release the Program Key to proceed to the
next step.
Auto Off
10. The LED Display now shows the stored Auto Off time as "AOx" (x=0 thru 9).
Time is shown as tens of minutes (e.g., "AO3" equals 30 minutes). A
display of "AO0" indicates that Auto Off is disabled. Choose one of the
following:
a) Press and release the Program Key (
) to keep the currently stored Auto Off
time.
b) Press and release the Scroll Up
Key to enable and/or increase the Auto Off.
Press and release the Program Key to proceed to the next step.
d) Press and release the Scroll Down
Key to decrease or disable the stored Auto
Off time. Press and release the Program Key to proceed to the next step.
Exiting the Programming Menu
11. The LED Display now reads "End". The Set-Up Mode procedure is now complete.
Choose one of the following steps:
a) Press and release the Scroll Up
Key to exit Set-Up Mode and
return to normal operation.
b) Press and release the Scroll Down
Key to return to the start of
the Set-Up Mode procedure. Go back to step 4.
Factory Settings
TW 50 systems come equipped with a number of features, which may be adjusted as desired by the
user. Listed below are the features and factory settings of each. To change and/or learn about any
of these features, refer to the applicable part of the “Programming Your System” section of this
manual.
Feature Factory
Setting
Password None
Entered
°F for 115 VAC Systems
Default Temperature Scale (°C/°F)
°C for 230 VAC Systems
“HI” (Upper) Temperature Limit
454 °C (850 °F)
“LO” (Lower)Temperature Limit
260 °C (500 °F)
Set Temperature
“OFF”
Temperature Setback
Enabled, 30 minutes
Auto Off
Enabled, 60 minutes
Factory Settings