8.  Set LCD Contrast 

Press the UP   and DOWN 

 to enter increase or decrease LCD contrast.  The range of contrast is 

1 to 100. Press and release the PROGRAM Key 

 to move to the next step.

 

 
9.  Set LED Backlite 

Press the UP   and DOWN 

 to enter increase or decrease LCD contrast.  The range of backlite is 

1 to 100. Press and release the PROGRAM Key 

 to move to the next step.

 

 
7.  Exiting the Programming Menu  

The LED Display now reads "End". The Set-Up Mode procedure is now complete. Choose one of the 
following steps: 
a)   Press and release the UP   Key to exit Set-Up Mode and return to normal operation. 
b)   Press and release the DOWN 

 Key to return to the start of the Set-Up Mode procedure. 

 

Temperature Adjust Mode 

 

To increase of decrease handpiece temperature, press the UP   or DOWN

 arrow key once. The 

display will show the current temperature setting for channel “1”. Press the UP   or DOWN

 arrow 

keys to increase of decrease handpiece temperature for channel “1”. Or press the 

 PROGRAM Key 

to move the next channel.  After a period of 10 seconds of inactivity, the display will return to normal 
operation.

 

 

Setting Channel Offset 

 

To increase of decrease handpiece temperature offset, press the 

 PROGRAM Key once. The display 

will show the current temperature offset setting for channel “1”. Press the UP   or DOWN

 arrow keys 

to increase of decrease offset temperature for channel “1”. Or press the 

 PROGRAM Key to move the 

next channel.  After a period of 10 seconds of inactivity, the display will return to normal operation.

 

 

Accessing Calibration Menu  

 
Press and hold the 

 PROGRAM Key and the   UP keys while powering on unit.  Release keys 

when “Software Version” appears.  Follow the instructional prompts to review or set each menu 
option. 
 
Calibration Instructions 
The steps for the procedure are: 
1.  Remove any offset from the system by disconnecting the handpiece from the system. Re-

connecting the handpiece and proceed to step 2. 

2.  LED should go to amber. Set the MBT 350°F to (700°C). 
3.  Record the actual temperature of the tip from your temperature verification device. 
4.  Place the MBT 350 into the Calibration mode. Start with the system power switch in the off 

position. Press and hold the 

 

PROGRAM Key and the  

 

UP key while turning the 

system on. Release both keys when the display reads version 1.2 or higher.  

5.  The display will now read Channel “1” System Cal?  Press the 

 

UP key to enter a temperature 

for channel “1”. Press 

 key / NO to move to the next channel. 

6.  Use the UP   and DOWN 

 keys to enter the temperature that you recorded by the temperature 

verification device. For example, your temperature verification device reads 695 °F. Scroll through 
until the display reads 695. 

7. Press 

the   PROGRAM Key to save calibration and move to the next channel. Upon exiting, 

LED will illuminate green and the display will return to normal operation mode. 

©2005 PACE Inc., Annapolis Junction, Maryland All Rights Reserved                                                     Page 15 of 19 
 

 

Summary of Contents for 5050-0552

Page 1: ...Operation and Maintenance Manual for the PACE MBT 350 Digital Soldering Desoldering System P N 5050 0552 Rev A TWF05 05...

Page 2: ...LED Operation 13 Operation 13 Accessing Programming Menu 16 Password Menu 13 Setting Temperature C F 13 Set Upper Limit 14 Set Lower Limit 14 Setback Time 14 Set Auto Off 14 Scan Enable Disable 14 Set...

Page 3: ...version system bears the CE Conformity Marking which assures the user that it conforms to all the requirements of EU directive EMC 89 336 EEC 73 23 EEC Specifications POWER REQUIREMENTS MBT 350 Versi...

Page 4: ...C to 50 C 32 F to 120 F Storage Temperature 40 C to 100 C 40 F to 212 F Capabilities All capabilities are dependent upon the use of the appropriate Functional Accessories or Work Aids refer to Basic O...

Page 5: ...Turns system ON 1 and OFF 0 controls input power to the system 7 PRESSURE ADJUSTMENT Controls variable airflow pressure delivery 8 PRESSURE PORT Quick connect fitting with provides airflow for Mini T...

Page 6: ...d to which a ground cable can be connected from the work piece or work surface as part of a static control program 14 AC POWER RECEPTACLE FUSE HOLDER Receptacle for providing power to the system from...

Page 7: ...t when the handpiece is powered on and for a period of time after power off DO NOT touch either the heater or the tip Severe burns may result 4 PACE Tip Tool Stands and handpiece cubbies are designed...

Page 8: ...ate injury May also be used to alert personnel to conditions procedures and practices which if not observed could result in damage to or destruction of the product or other equipment WARNING Used to d...

Page 9: ...eral safety precautions that personnel must understand and follow when using or servicing this product These precautions may or may not be included elsewhere in this manual Safety Electrical Requireme...

Page 10: ...ock in place 7 To avoid confusion among handpieces PACE recommends the use of colored cable markers Figure 3a P N 6993 0136 Cable Marker Kit to identify the particular handpiece Attach any two like co...

Page 11: ...l Stands or cubby s may be secured to each other by aligning mounting holes on stand sides Use hex head screws and thumb nuts to mount cubbys together Optional Instant Setback Cubby The optional Insta...

Page 12: ...display an instruction to enter the password Enter a four digit number selected using the scroll up down keys on the system front panel when a setting change is attempted Programming Menu The interfa...

Page 13: ...disable the display contrast and backlight settings To access set up mode press and hold the PROGRAM Key while powering on unit Release key when Software Version appears Pressing the PROGRAM Key will...

Page 14: ...ess and release the Scroll Down Key to decrease or enter 00 to disable the stored Temperature Setback time Press and release the PROGRAM Key to proceed to the next step The LED Display now shows the s...

Page 15: ...channel 1 Or press the PROGRAM Key to move the next channel After a period of 10 seconds of inactivity the display will return to normal operation Accessing Calibration Menu Press and hold the PROGRA...

Page 16: ...user to delete the hello message Press the UP key to change the hello message or press the DOWN arrow key to exit and return the normal operation mode Corrective Maintenance Power Source Refer to the...

Page 17: ...14 0 0 1 1 9 Cable Marker Kit 6993 0136 P1 0 0 1 1 10 Angle Bracket Kit 6018 0097 P1 0 0 1 1 11 PACE Screwdriver 1100 0230 0 0 1 1 12 SX 80 Blue Connector Kit 6993 0266 P1 0 0 1 1 13 MT 100 Blue Conne...

Page 18: ...corporated Annapolis Junction Maryland U S A ARM EVAC FLO D SODR MINIWAVE PACE SENSATEMP SNAP VAC SODRTEK SODR X TRACTOR THERMOFLO THERMOJET THERMOTWEEZ VISIFILTER THERMO DRIVE and TOOLNET PACE produc...

Reviews: