Safety 

 

Safety Guidelines  

 

The following are safety precautions that personnel must understand and follow when using or 
servicing this product. 

 

1.   

POTENTIAL SHOCK HAZARD - 

Repair procedures on PACE products should be 

performed by Qualified Service Personnel only.  Line voltage parts may be exposed 
when the equipment is disassembled.  Service personnel must avoid contact with these 
parts when troubleshooting the product. 

2.   To prevent personnel injury, adhere to safety guidelines in accordance with OSHA and 

other applicable safety standards.  

3.   SensaTemp handpiece heaters and installed tips are hot when the handpiece is powered 

on and for a period of time after power off.  

DO NOT

 touch either the heater or the tip.  

Severe burns may result. 

4.   PACE Tip & Tool Stands and handpiece cubbies are designed specifically for use with 

the associated handpiece and houses it in a manner that protects the user from 
accidental burns.  Always store the handpiece in its holder.  Be sure to place the 
handpiece in its holder after use and allow for cooling before storing.  

5.   Always use PACE systems in a well ventilated area.  A fume extraction system such as 

those available from PACE are highly recommended to help protect personnel from 
solder flux fumes. 

6.  Exercise proper precautions when using chemicals (e.g., solder paste).  Refer to the Material 

Safety Data Sheet (MSDS) supplied with each chemical and adhere to all safety precautions 
recommended by the manufacturer. 

 

 

System Set-Up 

 
 Set up the ST 25 system using the following steps and associated drawings. 
 

1.  Store the shipping container in a convenient location.  Reuse of these 

containers will prevent damage if you store or ship your system. 

2.  Place the Power Switch in the “OFF” or “0” position.  

 

Mounting Options 

 

The ST 25 can be placed directly on a workbench or it also can also be mounted under a workbench 
or shelf to conserve space (

optional

 

mounting bracket sold separately

).  To mount the system in 

this way (ST 50 shown): 
 

1.  Mount the bracket in the desired location (fasteners not 

supplied). 

2.  Insert the 2 Mounting Screws (head first) into the power 

source mounting slots. 

3.  Place the washers over the screws. 
4.  Fit the power source between the bracket’s support arms 

and place the screws into the slots on the support arms. 

5.  Place the nut on the screw and tighten by hand. 
6.  Angle the power source so the operator can see the front 

panel easily. 

7.  Tighten the nuts with a wrench or pliers. 

 
 
 
 
 
 
 

w w w . e k t

2

. c o m

Summary of Contents for 5050-0530

Page 1: ...Operation and Maintenance Manual for the SODRTEK ST 25 Soldering System P N 5050 0530 w w w e k t 2 c o m ...

Page 2: ... Stand 6 Handpiece Connection 6 System Power Up 6 Heater Burn In Procedure 6 Operation Variable Temperature Control 7 Temperature Dial Lock 7 LED Operation 7 Temperature Dial Adjustment 8 Corrective Maintenance Power Source 8 Handpieces 9 Packing List 9 Spare Parts 9 Service 10 PACE LIMITED WARRANTY STATEMENT 10 Contact Information 11 w w w e k t 2 c o m ...

Page 3: ...ower Source Power Requirements ST 25 Operates on 97 127 VAC 50 60Hz 90 Watts maximum at 115 VAC 60Hz ST 25E Operates on 197 253 VAC 50 60Hz 80 Watts maximum at 230 VAC 50Hz Temperature Specifications HandpiecesTip Temperature Range 204 to 455 C 400 to 850 F nominal Temperature Stability 1 1 C 2 F at idle from set tip temp NOTE Actual minimum and maximum Operating Tip Temperatures may vary dependin...

Page 4: ...Parts Identification Front Panel LED Power Switch Power Receptacle AC Power Receptacle Fuse Holder Temperature Selection Dial Earth Ground Receptacle w w w e k t 2 c o m ...

Page 5: ...ction system such as those available from PACE are highly recommended to help protect personnel from solder flux fumes 6 Exercise proper precautions when using chemicals e g solder paste Refer to the Material Safety Data Sheet MSDS supplied with each chemical and adhere to all safety precautions recommended by the manufacturer System Set Up Set up the ST 25 system using the following steps and ass...

Page 6: ...he AC Power Receptacle on the rear panel of the power source 2 Plug the prong end male end of the power cord into an appropriate 3 wire grounded AC supply receptacle CAUTION To insure operator and ESD EOS safety the AC power supply receptacle must be checked for proper grounding before initial operation NOTE Ensure that the system is placed in a well ventilated area Smoke will be generated during ...

Page 7: ... the handpiece heater This condition is evident for a short period of time when set temperature is reached and stabilizing or if the Variable Temperature Control setting is decreased If the LED never illuminates check for a faulty handpiece see Corrective Maintenance section Also if no handpiece is connected to the power source the LED will not illuminate Temperature Dial Adjustment The ST 25 syst...

Page 8: ...e fuse located in the AC Receptacle Fuse Holder with one of the same rated value Defective Heater Refer to the appropriate handpiece manual Handpiece will not heat Power Source Malfunction Contact PACE Power Source Corrective Maintenance Handpieces Please refer to the specific handpiece manual for the Heater Assembly Checkout Procedures Packing List Item Description Part Number ST 25 Only ST 25 E ...

Page 9: ...Operation and Maintenance Manual for the PS 90 Soldering Iron Handpiece Manual Number 5050 0443 Rev C w w w e k t 2 c o m ...

Page 10: ...not leave the PACE system unattended when in use 4 Repair on this product should be performed by Qualified Service Personnel only Set Up Tip Tool Stand The Tip Tool Stand can be mounted to the power source If the system will be placed on the workbench this is recommended If the power source is to be mounted under the workbench or shelf the Tip Tool Stand should not be mounted to the power source 1...

Page 11: ...76 P5 2 PS 90 Heater Assembly also fits PS 80 6010 0095 P1 3 PS 90 Flared Ring 1500 0074 P5 4 Retaining Nut for PS 70 PS 90 1410 0122 P5 5 Heater Set Screws 1348 0547 P10 NOTE Periodically clean the heater bore with a properly sized wire brush 3 16 O D to insure optimum heat transfer and proper tip grounding when Handpiece Connection Connect the handpiece connector plug into the Power Receptacle i...

Reviews: