I
NSTRUCTION
M
ANUAL
MEGA-M250b
Abrasive Cutter
3601 E. 34th St. Tucson, AZ 85713 USA Tel. +1 520-882-6598 Fax +1 520-882-6599 email: [email protected] Web: http://www.metallographic.com
Please read this instruction manual carefully and follow all installation, operating and safety guidelines.
Recirculation tank
The
MEGA-M250
is equipped with a mobile
three-chamber counter-current coolant tank.
The first chamber contains a coarse strainer
for removing larger debris.
Replacement of the coolant is accomplished
by rolling out the tank and removing the
water pump.
Note: Dispose of the old coolant in
accordance with federal, state and
local regulations.
Water
pump
Electrical
connection
Pressure
line
Pump valve closed
After cutting, it is recommended that the cutting
chamber be rinsed to prevent debris and
corrosion build-up.
Water flow
regulating valve
Rinse line
8
Drain
line
Three Chamber tank
with counter-current
flow
Coarse
strainer
Pump valve open
Tank
drain