Single Channel Wireless Air Spring Controls
L6597
7
5 SECURE WIRING HARNESS RELAY
Included in the wiring harness assembly is a built-in sealed relay which must be secured to prevent damage over time. When
all harness connectors are attached to the compressor assembly and controller, secure the relay in the nearby area that
leaves the harness unstrained.
If the relay has a built-in mounting bracket:
• Drill a #21 [4 mm] pilot hole through the mounting location. Secure the relay using the #10 x ¾” self-tapping screw.
• Torque screw to 8.5 N•m [75 in-lbs]
Use caution when drilling to not damage any wiring, fuel lines or other vehicle components near or behind the drill
location.
If the relay does NOT have a built-in mounting bracket:
• Secure relay to a rigid mounting location using provided tie straps
Do NOT mount the relay in a way which pulls or strains the harness wires.
6 ROUTE WIRING HARNESS TO BATTERY
Route the wiring from the kit mounting location to the engine bay and battery. Excess length is provided to ensure kit is
compatible with all applications. Allow adequate slack in wiring harness near connections to prevent vibrating components
from straining wires. Cut the harness to length as required for your install and secure harness away from moving parts or high
heat sources with provided tie straps.
PLEASE NOTE: If required, wire lengths can be extended. Ensure to use specified wire type and size as indicated on wiring
schematic. If extending wire lengths, individual runs must not extend beyond 10 meters [30 feet] from the controller.
4