HUMIDIFIER INSTALLATION

  1.  Mount  Humidifier  Unit  in  convenient  location  using 

Mounting Bracket (not shown).

  2.  Connect air supply to HF-1/4” Air Inlet Valve.

  3.  Connect water supply to HF-1/4” Water Inlet Valve.

  4.  Open air inlet valve and water supply valve 

under air 

supply valve

 check for leaks. Tighten connections if 

required.

  5.  

Turn humidistat control dial on item #1 counter-

clockwise to off position before plugging cord into 

grounded outlet

.

  6.  Reduce  water  flow  by  turning  U-3670  needle  stop 

adjustment knob at back of spray gun.  

Do not use to 

shut off spray.  If tightened too much needle can be 

pushed through tip.

  7.  Set Regulator item #2, between 45 & 60.  Start at 45 PSI 

and increase until you get a nice atomization.  Shop air 

must be 80 PSI or higher.

  8.  Plug unit into properly grounded Outlet (115V., 60cy).

  9.  Turn Humidistat control dial to on position and desired 

humidity. You will hear a “click” when activated.

 

10.  Water  flow  rate  may  be  adjusted  using  Item  #13  for 

Fluid  Adjusting  on  back  of  each  Spray  Gun.  Mist 

should always be absorbed into the surrounding 

air  without  settling  out  onto  the  floor  under  the  unit.  

CAUTION:

  DO NOT AIM DIRECTLY AT CEILING, 

WALL, MERCHANDISE OR MACHINERY.

SAFETY NOTE:

  Do Not allow water vapor to 

condense  or  leaks  to  drip  onto  floor  or  unit,  if  this 

condition exists, check for:

  a. Water leaks from connections or Spray Gun nozzles.

  b.  Insufficient  atomization.  Correct  by  increasing  air 

pressure and/or decreasing fluid flow.

  c.  Humidistat setting too high. Lower setting if necessary.

  d.  

  Open drain valve on R-76 Regulator/Condenser

 item #2 

periodically to drain airline moisture buildup. 

CAUTION:

  Guard Face and Eyes so escaping air and 

moisture do not cause injury.

WARNING:

  Humidifier must never be used to create 

a fog condition in which water may collect on the unit 

and produce an electrical hazard.

F910-2 UNIT

Air Inlet

1

3

4

2

11

10

Water Inlet

No.    Part No.  

Description

1.   

AR-15-1 

Aircap

2.   

AU-12 

Aircap Nut

3.   

AU-1 

Fluid Tip

4.   

A-AU-2-29/32 

Needle

5.   

AU-7B 

Fluid Body

6.   

U-3632 

Small O-ring

7.   

U-3633 

Large O-ring

8.   

U-3045 

Cylinder Shell

9.   

U-3664 

PTFE Piston Assembly

Located behind

Humidistat

1 2

6

7

8

9

3

4

5

 Do Not Use as a Shutoff by 

turning all the way Down, It will 
split the Tip.

Needle Lock

     Screw

12

13

11

10

MAJOR COMPONENTS FOR F900-SERIES HUMIDIFIERS

 No. 

Part No. 

Description

  1. 

845  

Humidistat

  2. 

R-76  

Regulator & Moisture Trap

  3. 

AH-JUR-1 

2 Spray Gun Heads

  4. 

T-04-10 

Water Tubing (10 Inches)

  5. 

F9-90-1/8 

Air Fitting to Regulator

  6. 

F9-90-1/4 

Fitting to Mount 90° (3)

  7. 

1/4 AHPP 

Pipe Plug

  8. 

F9-1-1/4 

Fluid Inlet    

    9.               T-04-4.5          AirTubing (4 1/2 Inches)

   10.              SM-880           Solenoid Valve

   11.              HF-1/4             Valve Assembly (1)Water & (1) Air

7

6

6

6

14

15

10.   

U-2500 

Piston Spring

11.   

U-3669 

Rear Cap  

 

 

12.   

H-153 

Set Screw

13.   

U-3670 

Needle Stop Adjustment Knob

14.        U-1432A                   Ball Stud

15.        U-1399                     Swivel Nut

16.        U-3687                     Packing Set    

9

5

Located in mounting 

block behind regulator

8

Located behind

regulator

16

Reviews: