5.Voice Recording

Enter “Voice  Recording”  and  press          to choose  on. Enter it; you 
can start the 10-second recording. After 10s, it will exit automatically.
Press      or      can end the recording manually. Receivers can hear 
this recording when there’s an alarm call.

6.Arm Delay Setting

Enter  “Arm  Delay”  menu.  Delete  the  preset  time  and  input  the  time 
(00~59seconds)  you  want  to  set.  After  this  setting,  when  you  arm 
(home arm/ away arm) the system, it will enter arming status after the 
preset delay time. (system default: 10s) 

7.Alarm Delay Setting

Enter  “Alarm  Delay”  menu.  Delete  the  preset  time  and  input  the  time 
(00~59seconds)  you  want  to  set.  After  this  setting,  when  there  is  an 
alarm, it will make call or send sms after the preset delay time. (system 
default: 10s)

7

8

8.Timely Arm/ Disarm

After  this  setting,  the  alarm  system  will  start  arm  status  and  disarm 
automatically at the preset time.
Method:  enter  “timely  arm/disarm”  menu.  You  will  see  the  screen 
displays  like  the  following  diagram.  “SUN”  means  Sunday.  Delete  the 
preset time first and then input the time you want to set (00:00~24:59). 
After  saving,  it  will  change  to  “MON”  automatically. That  means,  after 
each successful setting, it will change to the next day. 

9.Siren Setting for Alarm

The siren can be set on or off when there's an alarm.
Enter “Siren Setting” menu. You will see “Zone No.”. Delete the preset 
numbers and input the defense zone number (00~34) you want to set. 
Save it and then set the “Siren Duration” (00~59minutes). Save it and 
then set the “Built-in Siren”. Press            to choose on/off.
Siren Duration: siren ring time (default: 1minute)
Built-in Siren: the siren built-in the alarm panel

10.Voice Prompt

Enter  “Voice  Prompt”  menu,  you  can  set  these  functions  “PSTN  Off” 
“Arm & Disarm Siren” “Arm & Disarm Horn” as on/ off.
PSTN  Off:  turn  on  this  function;  the  screen  will  display  “PSTN  Off” 
when the telephone line is cut off. The panel will make two short beeps 
at the same time. 
Arm & Disarm Siren: turn on this function, the built-in siren of the panel 
will  make  one  short  beep  for  arm  operation  and  two  short  beeps  for 
disarm.

Voice Record

Off/On         >

Voice Record
In Recording

Time

            

10

Arm Delay

Second

10

Alarm Delay

Second

10

SUN
           Away Arm
12:00 Home Arm
21:35 Disarm

MON
          Away Arm
          Home Arm
          Disarm

:
:
:

:

Zone No.
                    

00

Siren Duration
                    
Minute

01

Built-in Siren

On                 >

Battery Low-volt

Off/On         >

Sensor Low-volt

Off/On         >

PSTN OFF

Off/On         >

Function Settings

Function Settings

Summary of Contents for PAMCID430GT

Page 1: ...ntelligent GSM PSTN Auto Dial Alarm System For a better understanding of this product please read this user manual thoroughly before using it Profile Alarm System 2013 5 V1 0 GSM PSTN GSM Level 99 Dis...

Page 2: ...larm 8 10 Voice Prompt 9 11 Ring Time Setting 9 12 Add or Delete Wireless Sensors 9 13 Defense Zone Setting 9 14 Alarm Center Setting 11 15 User Password 12 16 Program Password 12 17 Wireless Siren Se...

Page 3: ...ion that could be upload to the alarm center includes alarm arm disarm battery low power external power failure recovery period manual test and sensors low power Compatible with all our accessories in...

Page 4: ...word check the alarm working status record Press to upturn or downturn emergency alarm one short beep one short beep per second two short beeps two short beeps the screen will display AC Power Fail on...

Page 5: ...tion Number Setting SMS attention number means the number that will receive sms when the external power is cut off or recovered the system is armed or disarmed the telephone line has error etc The sms...

Page 6: ...it will change to MON automatically That means after each successful setting it will change to the next day 9 Siren Setting for Alarm The siren can be set on or off when there s an alarm Enter Siren S...

Page 7: ...nt to set Then you could do the settings Zone activate disable this means you want this zone work or not Defense line 0 24 hour defense zone 1 out arm zone 2 home arm zone 00 SOS help alarm informatio...

Page 8: ...ord This password is used to disarm the alarm system by panel keypad This system supports 3 user passwords A B C Password A is also the remote call password Method Enter Password Setting menu Delete t...

Page 9: ...oller Operation Users can use remote controller to set system as Out Away Arm Home Arm Emergency Alarm and Disarm Out Arm Press button Disarm Press button Home Arm Press button Emergency Alarm Press S...

Page 10: ...system will call each preset numbers for 3 times in order If you hang up directly without answering the call the system will call each preset number for 3 times circularly If you answer the call you w...

Page 11: ...r and damage the circuit board of the alarm system It is recommended that you check and test the alarm system periodically Check the main unit every three months 1 Whether it can arm disarm normally 2...

Page 12: ...for this main unit Please read the suggestions above carefully and follow the instructions herein If any of the equipment does not work properly please send it to the dealer or authorized service poi...