4) If there’s no operation over 30seconds, the panel would exit setting
status automatically.
1.Enter Settings
Press , then input the 4-digit program password and to enter
setting status. (default password: 1234)
2.Time Setting
After enter settings, you could see “clock setting”. Enter it to set the
time and date. The first group is for time (hour: minute: second), the
second is for date (month/day/year) and the last is for day. Please
press to clear the previous data and then input the correct data.
And finally press to confirm.
Operation figures:
3.Alarm Call & SMS Number Setting
This system can store 5 groups of alarm numbers. When alarming, it
will make alarm call or send sms to these numbers. And the call will be
made in order for three times automatically, until someone gets through
it.
Method:
enter “phone No. setting” menu, choose “Phone Alarm” or
press to choose “SMS Alarm”. Press and then delete the
preset numbers. Input the number you want to set. Save it, then you
will see the “phone group” change to “2” automatically. That means
after setting a group of number successfully, it will enter the setting of
next number automatically.
Note:
Each group of number could not exceed 15-digit.
Each group of number can save only as phone call number or sms
number.
The panel will handle the numbers in serial order. For example, you set
the first number as sms number, and the second as phone number, it
will send sms before making alarm call.
4.SMS Attention Number Setting
SMS attention number means the number that will receive sms when
the external power is cut off or recovered, the system is armed or
disarmed, the telephone line has error, etc. The sms content will also
be displayed on the screen. This system can store 1 SMS attention
number.
This number will not receive defense zone alarm sms.
Method: enter “SMS Setting” menu, delete the preset numbers and
then input the number you want to set. Save it, then you will see “AC
Power Recover”, “Arm/ Disarm SMS”, “PSTN Off”, “Battery Low-volt”,
and “Sensor Low-volt”. Press to choose on or off. (System
default: off)
AC Power Recover: when the external power supply is off more than 8
seconds, the panel will send sms “AC Power Fail”; when the external
power supply is recovered for 30s, it will send sms “Alarm System: AC
Power On”.
Arm/ Disarm SMS: when system is armed or disarmed, it will send
sms “Alarm System: Armed/ Disarmed”.
PSTN Off: when the telephone line is cut for 5 seconds, the panel will
send sms “Alarm System: PSTN Off”.
Battery Low-volt: when the main panel battery is in low power, it will
send sms “Alarm System: Low-volt”.
Sensor Low-volt: when the sensor (PIR sensor, door contact sensor)
battery is in low power, it will send sms “Sensor Low-volt”.
NOTE: This version alarm system does not have “
function. Please kindly contact us if required.
sensor Low-volt”
Function Settings
Function Settings
Clock Setting
Phone No.setting
Sms Serring
Voice Recording
Clock Setting
05/01/2013
WED
14:35:21
Phone Group 1
Phone Alarm >
SMS Alarm
Phone Group 1
Phone Alarm >
1358888888
Phone Group 2
Phone Alarm >
SMS Phone No
13588888888
AC Power Recover
Off/On >
Off/On >
Am/Dlsarm SMS