VB 450-200/300 

- Unloader  Valve                                              

 

Technical Booklet:

 

E 258 

Pressure regulating unloader valve. 
It bypasses water flow at low pressure when gun shuts off. 

 

 

 

 

 

 

 

 

 

 

 

DN 32 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Technical Data 

Max. Flow Rate: 450 l/min.   Max. Temperature: 90°C 

(1) 

P/N 

 
 
 
 

RATED 

PRESSURE 

 
 

bar - MPa 

PERMISSIBLE

PRESSURE 

 
 

bar - MPa 

MIN. 

ADJUSTABLE 

PRESSURE 

 

bar - MPa 

(2)MAX PRESS. 

INCREASE AT 

SYSTEM SHUT 

OFF 

(3)PRESSURE 

DROP AT 

BYPASS 

RESET 

INLET 

OUTLET 

BYPASS 

WEIGHT 

 
 
 

60.4020.00 

200 - 20 

220 - 22 

20 - 2 

10,7% 

43,8% 

1“1/4 Bsp FF  1“1/2 Bsp F 

5950 

60.4030.00 

300 - 30 

330 - 33 

30 - 3 

7,8% 

43,3% 

1“1/4 Bsp FF  1“1/2 Bsp F 

6025 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(1)

  The valve is especially designed for a constant use at a water temperature of 60°C. It can withstand up to a max. 

temperature of 90°C for short intervals only. 
 

(2) 

The max. pressure increase at system shut off is a percent value of calibration pressure. When it occurs, the valve is 

set in operation and the whole fluid is diverted into bybass. 

 

(3)

  The  pressure  decrease  at  bypass  reset  is  a  percent  value  of  calibration  pressure.  It  indicates  the  pressure  drop 

required for the valve to restore pressure in the system.  

 
 

Instruction, Maintenance, Installation, Spare Parts Booklet. 

For a correct use of the item, please follow the instructions. 

Please copy all relevant information on the use and maintenance booklet of 
the machine. 

n. 12.9258.00 

 
 

 

60.4020.00

   VB 450/200    

 

                   

1”1/4 Bsp FF     

 

60.4030.00

   

VB 450/300                        1”1/4 Bsp FF      

 
 
      -Intended for use with high flow rates 

-Special steel spring with superior mechanical features, to maintain 
calibration settings for longer 

      -Check valve specifically designed to prevent jammings 
      -Screw/Locknut adjusment to set maximum pressure level 

-Dynamic seals with O-ring and sliding gasket 
-Fixing screw slots 

Summary of Contents for VB 450-200

Page 1: ...x pressure increase at system shut off is a percent value of calibration pressure When it occurs the valve is set in operation and the whole fluid is diverted into bybass 3 The pressure decrease at bypass reset is a percent value of calibration pressure It indicates the pressure drop required for the valve to restore pressure in the system Instruction Maintenance Installation Spare Parts Booklet F...

Page 2: ...ssurized outlet channel Select the right nozzle size which allows a regular discharge into bypass of at least 5 of the total flow rate of the system This will keep a constant pressure setting and prevent pressure spikes at shut off which could damage the system By nozzle wearout the pressure drops When replacing the nozzle reset the system to the original pressure level OPERATION The valve regulat...

Page 3: ...ect use follow the instructions given in this booklet and re print them on the Use and Maintenace Manual of the machine Make sure that you are given the original Declaration of Conformity for the chosen item This booklet is applicable for all unloader valves type VB 450 200 300 MAINTENANCE All maintenace operations must be carried out by qualified personnel only ROUTINE every 400 hours of operatio...

Page 4: ...4003 51R Shutter M 12 1 3 10 10 3206 08R O ring 2 62x28 25 mm Ni85 1 10 11 60 4005 31R Bushing 1 3 12 10 4084 00R Back up ring 16x20 5x2mm 1 5 13 10 3181 20R O ring 2 62x15 88 mm 1 10 14 60 4007 31R Bushing 1 3 15 10 3246 05R O ring 3 53x28 17 mm 1 5 16 10 4096 00R Back up ring 28x34x2mm 1 5 17 60 4004 51R Piston M 12 1 3 18 14 7465 00R Ball 1 2 Sst 1 5 19 60 4009 31R Piston holder 1 1 20 60 4010 ...

Reviews: