background image

 

ATEX HYDROKINETIC ROTATING CLEANING HEADS 

SAFETY NOTE 

SN01 

Rev. 00 

Date 22/04/2020 

Pag. 3 of 10 

 
 

1.

 

INTRODUCTION 

 
PLEASE  READ  THE  FOLLOWING  INSTRUCTIONS  CAREFULLY  BEFORE  INSTALLING  ANY  EC-MARKED  PART  (CLEANING 
HEAD),  ACCORDING  TO  THE  ATEX  PARTS  DIRECTIVE  2014/34/EU  IN  A  POTENTIALLY  EXPLOSIVE  ATMOSPHERE  AS 
DEFINED IN THE ATEX WORK ENVIRONMENT DIRECTIVE 99/92/EC
. This manual must be brought to the attention of 
the personnel working with the head, and must be illustrated to the personnel qualified for maintenance and repair of 
the head. Any substantial modification to the head will not be allowed. 
 
Any  substantial modification must  be  authorized  by P.A.  S.p.A. (for  a broader definition  of  substantial modification, 
please see maintenance manual). 
 

2.

 

DESCRIPTION OF THE PRODUCT 

 

2.1

 

CLASSIFICATION & MARKING 

 
The  unequivocal  identification  of  the  equipmet  is  to  be  verified  by  the  data  imprinted  on  the  body  and  by  the 
declaration  of  conformity  attesting  that  the  tool  was  subjected  to  a  conformity  test  according  to  directive 
2014/34/EU, annex VIII, requiring for a technical file to be sent to a Certification Body. 
 
The marking of the cleaning head is: 
 

 

2460

    

II 1 G Ex h IIC T6...T4 Ga 

II 1 D Ex h IIIC T85°C...T135°C Da 

Ta: 0°C / +90°C 

 

Presafe 20 ATEX 319809 

 
where: 

 

Symbol 2460: DNV GL Presafe AS Certification Body 

 

Symbol CE Ex: in accordance with directive 2014/34/EU 

 

Group II: suitable on surface 

 

Category 1: suitable in zones 0 - 1 – 2 for gas and in zone 20 – 21 -22 for dust 

 

Substance type: G (gas) and D (dust) 

 

Specific type of protection: “Ex h” (construction safety) 

 

Group of gas/dust: IIC (gas) and IIIC (dust) 

 

Temperature Class/Max surface temperature: T6…T4 (gas) and T85°C…T135°C (dust) (see note 1) 

 

EPL: Ga (gas) and Da (dust) 

 

Ambient Temperature: 0 ÷ +90 °C 

 

Certificate Number: Presafe 20 ATEX 319809 

 

Additional marking on equipment: material of the Seals: E – N – K – V (see note 2) 

 
The measures of prevention and protection described in this manual do not determine the level of safety required if 
the  heads  will  not  be  used  according  to  the  provisional  use,  nor  if  they  were  not  installed  and  subjected  to 
maintenance according to the terms of use or appropriate requirements.  

Summary of Contents for 25.4600.20

Page 1: ...2460 2460 ...

Page 2: ...2460 ...

Page 3: ... SAFETY NOTE SN01 Rev 00 Date 22 04 2020 Pag 1 of 10 DOCUMENT REVISION REV DATE MODIFICATION 00 22 04 2020 First issue PREPARED BY RGQ Michele QUATTRONE SIGNATURE CHECKED BY DUT Fabio PEDRONI SIGNATURE APPROVED BY AD Alberto BENETTI SIGNATURE ...

Page 4: ...5 USE WORKING 6 3 5 1 WORKING ADJUSTMENT 6 3 5 2 SUITABLE NON SUITABLE USE 7 3 5 3 DANGEROUS AREAS 7 3 5 4 DANGER POSSIBLE RISKS 7 3 5 5 PPE PERSONAL PROTECTIVE EQUIPMENT PROCEDURES TRAINING 8 3 6 SYSTEM PROCEDURES 9 3 6 1 TOOLS MACHINERY 9 3 6 2 LOAD UNLOAD 9 3 6 3 START STOP 9 3 7 INSPECTION ORDINARY EXTRAORDINARY MAINTENANCE SERVICE CLEANING 9 3 7 1 PRECAUTIONS 9 3 7 2 ORDINARY MAINTENANCE AND ...

Page 5: ... subjected to a conformity test according to directive 2014 34 EU annex VIII requiring for a technical file to be sent to a Certification Body The marking of the cleaning head is 2460 II 1 G Ex h IIC T6 T4 Ga II 1 D Ex h IIIC T85 C T135 C Da Ta 0 C 90 C Presafe 20 ATEX 319809 where Symbol 2460 DNV GL Presafe AS Certification Body Symbol CE Ex in accordance with directive 2014 34 EU Group II suitab...

Page 6: ...when installed in a potentially explosive environment The appliance in question grants that potential sources of priming are not activated in normal functioning and even in case of foreseeable and rare failure or malfunction Breakage or failure to the appliance can happen In that case it is necessary to check the causes of failure When these are traced down to the appliance they must be removed No...

Page 7: ...subject to shock impacts tumbles deteriorment and other damaging which could compromise the function of the head Any eventual damage must be immediately communicated to P A S p A for assessment 3 2 INSTALLATION 3 2 1 WARNING Each installation or reinstallation must be performed by qualified personnel duly trained and informed on the related risks even concerning the instructions of this document W...

Page 8: ...ection grade minimum IP54 for Gas and IP6X for powders Insert the connection tubes entry and exit following a good technique and using acknowledged components adopting the foreseen clamping instructions During the connection of the tubes make an electrical earth link up with a minimum cable size 4mm observing the prescribed terms for equipotential connections Inspection after installation to be ca...

Page 9: ...nsidered in the planning stage in view of the safety measures adopted The Company P A S p A declines all responsibility for damage to persons animals or things derived by an improper use of the apparatus a o the non observance of the dispositions contained in the present manual 3 5 3 DANGEROUS AREAS Particular attention has to be reserved to any area potentially explosive around the head and also ...

Page 10: ...ated back pressure to the nozzles acts negatively on the head compromising the set calibration The nozzles must be exempt from back pressure They must not be blocked and no flow from the nozzles towards the inside of the head is permitted Ambient risks Ambient conditions different than those specified can cause a danger source They can cause dangerous service conditions with relation to the proces...

Page 11: ... certify that the operator is opportunely instructed to carry out all the safety procedures hygiene in the work areas according to the protocol in order to avoid any eventual risks deriving from the operations mentioned above 3 7 2 ORDINARY MAINTENANCE AND CLEANING After a normal daily usage wash the inside of the head with clean water without any additives Carry out an internal check after 100 ho...

Page 12: ...tenance replacement the removal of the head from the application is permitted only when the apparatus is not under pressure and in the absence of a potential explosive atmosphere Before reusing or reutilizing the head after washes general maintenance or any other necessary operation follow the warnings as seen on paragraph 3 1 1 of this safety note After reinstalling the device and before placing ...

Page 13: ...cin iniett 2mm 25 4600 24 MI63 45 test mot idrocin iniett 2mm 25 4600 30 MI63 50 test mot idrocin iniett 3mm 25 4600 40 MI63 50 test mot idrocin iniett 4mm 25 4600 50 MI63 50 test mot idrocin iniett 5mm 25 4902 25 MI63A 50 1 8 tes id cin inie 2 5mm Atex 2460 ...

Page 14: ...An elast E 20 inox 1 10 25 80 0207 52R Corona z 50 inox 1 1 26 10 3080 58R An OR 1 78x56 87 mm Vi 70 2 10 27 80 0219 51R Tappo EI M14x1 inox 3 3 28 10 3060 10R An OR 1 78x12 42 mm Vi 70 3 10 29 80 0221 51R Iniettore 2mm inox 3 3 29 80 0222 51R Iniettore 3mm inox 3 3 3 29 80 0223 51R Iniettore 4mm inox 4 3 3 29 80 0224 51R Iniettore 5mm inox 5 3 3 30 10 3003 00R An OR 1x8 mm 3 10 31 80 0212 84R Boc...

Page 15: ...hydr driv 2mm inject 25 4600 24 MI63 45 Tank cl hydr driv 2mm inject 25 4600 30 MI63 50 Tank cl hydr driv 3mm inject 25 4600 40 MI63 50 1 8 inject 4 00mm 25 4600 50 MI63 50 Tank cl hydr driv 5mm inject 25 4902 25 MI63A 50 Tank cl hy driv 2 5mm Atex 2460 ...

Page 16: ... 1020 05R Snap ring E 20 Sst 1 10 25 80 0207 52R Ring gear z 50 Sst 1 1 26 10 3080 58R O ring 1 78x56 87 mm Vi 70 2 10 27 80 0219 51R Plug int hex M14x1 Sst 3 3 28 10 3060 10R O ring 1 78x12 42 mm Vi 70 3 10 29 80 0221 51R Injector 2mm Sst 3 3 29 80 0222 51R Injector 3mm Sst 3 3 3 29 80 0223 51R Injector 4mm Sst 4 3 3 29 80 0224 51R Injector 5mm Sst 5 3 3 30 10 3003 00R O ring 1x8 mm 3 10 31 80 02...

Page 17: ......

Page 18: ......

Page 19: ......

Page 20: ...P A S p A Via Milano 13 42048 Rubiera Reggio Emilia Italy Tel 39 0522 623611 Fax 39 0522 629600 info pa etl it www pa etl it COMPANY WITH QUALITY MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001 ...

Reviews: