background image

5

Screw

Screw

1 Screw

Panel with 

Exhaust 

Opening

Panel without 

Exhaust Opening

Panel

A

A

A

D

D

B

B

B

C

D

D

C

C

Parts: 

A. Panel 

B. Panel with one exhaust hose opening

  C. Panel without exhaust hose opening 

D. Screws to lock panels together

1.  Assembly Panel 

Slide Panel B and C into Panel A and size to window 

width. Win dows sizes vary. When sizing the window 

width, be sure that the window kit assembly is free from 

gaps and/or air pockets when taking measurements.

2.  Security Panels 

Insert the screws into the holes that correspond with 

the width that your window requires to ensure that 

there are no gaps or air pockets in the window kit 

assembly after installation. 

Summary of Contents for 1PPEC8000

Page 1: ...RTABLE AIR CONDITIONER FOR MODELS 1PPEC8000 1PPEC10000 1PPEC12000 Before using your air conditioner please read this manual carefully and keep it for future reference along with your receipt USER MANU...

Page 2: ...________________________ Purchase Date ________________________________________ Store Purchased _______________________________________ Installation Date ______________________________________ Install...

Page 3: ...ed during the sunniest part of the day cooling mode Keep doors and windows closed to keep cool air in and warm air out cooling mode or keep warm air in and cool air out heating mode for units with hea...

Page 4: ...f gas and the amount please refer to the relevant label on the unit itself Installation service maintenance and repair of this unit must be performed by a certified technician Product uninstallation a...

Page 5: ...ning or performing maintenance Unit must be plugged into its own dedicated outlet Never unplug the unit by pulling on the power cord Do not install the unit in rooms containing gas oil or sulfur Do no...

Page 6: ...est follow the steps below that correspond to the plug on your unit NOTE Your unit s power cord may differ from the one shown If test button is pressed and unit can still be turned on current leakage...

Page 7: ...charge Opening 9 Condensation Drain Hole 10 Power Cord 10A Power Cord Wrap 11 Exhaust Hose 12 Window Kit Adapter 13 Exhaust Hose Connector 14 Remote Control 15 Caster Locks 16 Window Kit Screws 2x 17...

Page 8: ...The window kit and exhaust hose do not need to be installed when the unit is used as a fan or in DRY mode NOTE The supplied window kit can be installed in sliding windows or double hung windows up to...

Page 9: ...her 1 Assembly Panel Slide Panel B and C into Panel A and size to window width Win dows sizes vary When sizing the window width be sure that the window kit assembly is free from gaps and or air pocket...

Page 10: ...ess 4 Attach the Window Kit Adapter to the Window Kit Attach the Window Kit Extension Adapter to the Window Kit Adapter if necessary Close the window tightly Your Portable Air Conditioner is ready to...

Page 11: ...s of the unit but to fully utilize the unit s features you must use the remote control TURNING THE UNIT ON MODES Plug unit into the wall outlet Two lines appear on the display indicating that the unit...

Page 12: ...comfort Maximum speed to achieve the target tempe rature as rapidly as possible Auto fan the unit automatically selects the most suitable fan speed in relation to the temperature set on the digital d...

Page 13: ...ther to operate in COOL or FAN mode To properly set this mode Press the MODE button until the SMART symbol appears SLEEP FUNCTION This mode can only be set with the remote control Please refer to remo...

Page 14: ...ace caster locks under the front wheels This air conditioner is equipped with MIST technology which means the water tank nearly never fills Hence water drainage will generally only be required at the...

Page 15: ...oner by pressing the ON OFF button Ensure that the unit is in COOL or DRY mode The compressor will start approximately 3 minutes after the unit is switched on CONTINUOUS DRAINAGE SEE FIG B BELOW Thoug...

Page 16: ...emote control and the receiver The remote control must be handled with extreme care Do not drop it or expose it to direct sunlight or sources of heat For best operation do not mix old and new batterie...

Page 17: ...ed by pressing the FAN button until the required speed is selected AUTO HIGH MED LOW NOTE In COOL mode the unit automatically removes excess moisture from the air DRY MODE Keep the windows and doors c...

Page 18: ...the SWING button to activate this function Press the SWING button again to deactivate this function SETTING THE TIMER The timer can be used to delay the unit s start or stop time to avoid wasting elec...

Page 19: ...CE CLEANING Before cleaning or performing maintenance turn the unit OFF by pressing the ON OFF button on the control panel or ON OFF button on the remote control Wait for a few minutes then unplug fro...

Page 20: ...t speed setting These specifications are for reference only For actual data please refer to the rating label on the back of the unit If the temperature of the operating environment is higher than the...

Page 21: ...lter is dirty Clean filters as described in this manual There are heat sources in the room oven hairdryer etc Eliminate the heat sources The air exhaust hose is detached from the unit Fit the exhaust...

Page 22: ......

Page 23: ......

Page 24: ...y Perfect Aire LLC 5401 Dansher Rd Countryside IL 60525 844 4PA AIRE 844 472 2473 www perfectaire us Specification and performance data is subject to change without notice Printed in China PA User_1PP...

Reviews: