background image

Feature Locations   

 

ON 

 

    OFF 

Max.Amps 

Volt/Amp 

Watt/PF   

KWH/Leakage 

Elapsed Time 

10 Normal Outlets 

NFB Short Breaker 

 

Display Panel   

   

Surge

OK

 

Abnormal

Voltage

Volt

 

 

 

Watt

 

 

 

KWH

 

 

 

Amp

 

 

 

mA

 

 

 

%

 

 

 

Day

 

 

 

Hour

 

 

 

Wiring

OK

 

 

 

MAX

 

REPLACE

Over Load

MIN

NO Load

Over

Current

Ground

OK

 

Over current

No Appliance connected

Power Factor

Elapsed Days

Kilo - Watt - Hour

AC Power 

AC Voltage

Line

Neutral Wired Correct

Grounded Correct

Surge Protection Ready

Up to date Max.

Out of Range Voltage

Defect Detect 

Elapsed Hours

Leakage Current

AC Current

Up to date Min.

Over 15A Max Current

 

Quick Start Guide:   

Use these quick start instructions to get up and running in just a few minutes. Be sure to review all the operating 

instructions later to ensure full enjoyment of the product.   

1.  Connect the Kill A Watt

 

PS

 unit to the outlet and the appliance to the unit.   

2.  The LCD display will flash. Press any of the function keys to stop the flashing.   

3.  Press the OFF key. The OFF key will illuminate red.   

4.  Press the ON key. The ON key will illuminate green and the attached appliance will be powered.   

5.  If the attached appliance is turned off and is not consuming any power, the unit will detect no load. The 

ON  key  will  go dark  and  the  “NO  Load” icon  will  flash  on  the  LCD display. THIS  IS  NORMAL.  If  the 
attached appliance is 

then turned on, the unit will detect a load, the ON key will illuminate and the “NO 

Load” indicator on the LCD display will disappear.   

6.  Pressing  the  Volt/Amp  key  will  cycle  through  currently  measured  voltage  (Volts),  current  (Amps)  and 

Maximum/Minimum measured values.   

Shop for P3 products online at:

1.877.766.5412

www.

PowerMeterStore

.ca

Summary of Contents for Kill A Watt PS

Page 1: ...lectronics and find out what they are actually costing you Simply connect these appliances to the Kill A Watt PS and it will assess how efficient they are while the built in surge protection keeps them safe Advanced features such as over current over voltage and no load detection provide clean safe power to your expensive equipment Check the quality of your power by monitoring Voltage Amperage KWH...

Page 2: ...ed for ventilation and to ensure reliable operation of the product and to protect it from overheating and these openings if any must not be blocked or covered The openings if any should never be blocked by placing the product on a bed sofa rug or other similar surface This product should not be placed in a built in installation such as a bookcase or rack unless proper ventilation is provided or th...

Page 3: ...ts have fallen into the product If the product has been exposed to rain or water If the product does not operate normally by following the operating instructions Adjust only those controls that are covered by the operating instructions as an improper adjustment of other controls may result in damage and will often require extensive work by a qualified technician to restore the product to its norma...

Page 4: ...e Breaker Over Load protection Wall Mount Instructions Optional 1 Use 3 4 inch no 8 screws or similar 2 Space the 2 screws about 9 inches 285mm apart according to the figure Leave about 1 4 inch 5mm of the screw head protruding from the surface 3 Place the unit against the surface with the screw heads fitting into the mounting holes 4 Move the unit downwards to secure the mounting holes onto the s...

Page 5: ...to ensure full enjoyment of the product 1 Connect the Kill A Watt PS unit to the outlet and the appliance to the unit 2 The LCD display will flash Press any of the function keys to stop the flashing 3 Press the OFF key The OFF key will illuminate red 4 Press the ON key The ON key will illuminate green and the attached appliance will be powered 5 If the attached appliance is turned off and is not c...

Page 6: ...an power to your connected appliances The ON key will illuminate in green The unit will measure power and the function keys and LCD display will operate 3 While the unit is turned ON if all loads to the unit are removed then the No Load function will detect this condition and automatically turn off power to the 10 built in outlets Both the ON and OFF keys will be dark and a NO Load indicator will ...

Page 7: ...eakage current indicated by the MIN icon The display will return to the currently measured values after a few seconds Pressing and holding the KWH Leakage key for a few seconds will delete the memorized MAX MIN values for leakage current There are no MAX MIN values for KWH as it is a cumulative value IF YOU NOTE SIGNIFICANT LEAKAGE CURRENT MEASUREMENTS STOP USING THE CONNECTED APPLIANCE S IMMEDIAT...

Page 8: ... higher setting Then press the OFF key and then the ON key to turn the power back on 4 Abnormal Voltage mode When the voltage presented at the wall outlet if over or under the normal voltage range the unit will switch to Abnormal Voltage mode The power will be switched off to the 10 outlets The red LED in the OFF switch will flash The LCD will display the protected voltage value The Abnormal Volta...

Page 9: ...Wire OK icons will disappear 7 Surge Protection The unit features a self test function If the surge protection circuitry is operating properly the LCD display with indicate with the Surge OK icon If the surge protection has failed the Surge OK icon will disappear 8 EMI Filter The unit features a built in EMI electro magnetic interference filter to reject noise from the AC power line 9 Internal Swi...

Page 10: ...ied technician This is the abnormal voltage too high or too low protection function 5 No Load icon on the LCD display flashes The unit will power on automatically when the load returns This is the no load protection function to reduce the chance electrical shock or damage 6 No Load icon continues to flash when appliances are connected and turned on Increase the number of connected appliances The m...

Page 11: ...nual NFB LoadAmp 100 15A LoadAmp 150 22 5A 1Hour LoadAmp 200 30A 4 40sec LoadAmp 400 60A 0 42 5sec LoadAmp 600 90A 0 1 1 8sec No Load Detector Off 0 2W On 0 2W 0 1W 3sec 3sec Surge Protection Maximum energy Dissipation Joules L N L G N G 2040 J 50ns N A Maximum Clamping Voltage 359 V Maximum Surge Current 60000A EMI Filter Up to 20db for 100K to 20MHz 1 Display will flash when maximum count is rea...

Page 12: ...ed This warranty is in lieu of all warranties expressed or implied including the implied warranties of merchantability and fitness for a particular purpose which are expressly excluded or disclaimed P3 shall not be responsible for consequential incidental or other damages and P3 expressly excludes and disclaims liability for any damages resulting from the use operation improper application malfunc...

Reviews: