11.3 Grating
In GRATING cut position, the minimum current stays at 20A and the maximum at 40A.
When the arc moves from the solid to the grating open area, the generator returns automatically in pilot arc condition and the cutting arc starts again touching a new
solid area. We recommand the stand off spacer to improuve the spare parts life and the use of the tip (6)
11.2 Standard Solid Cutting
Contact Cutting:
in certain applications the contact cutting may be required even with current over 40A (ex.:high cutting speed on thin metal sheet or on high ticks where an high cutting precision is required).
In those application use spare parts described in the picture.
Use for current 40
÷
70A code
4 gas diffuser
Z0061AA
15 outer nozzle
Z0096AA
16 shield cup
Z0140AA
12 Contact tip Ø 1,0 | for current 40
÷
55A Z0093AA
12 Contact tip Ø 1,2 | for current 55
÷
70A Z0094AA
Use for current 70
÷
100A code
5 gas diffuser
Z0062AA
15 outer nozzle
Z0096AA
17 shield cup
Z0097AA
13 contact tip Ø 1,5 | for current 100A
Z0095AA
Use
code
4 gas diffuser
Z0061AA
6 contact tip Ø 0,9 Z0063AA
9 outer nozzle
Z0070AA
11 doubler pointer spacer
Z0072AA
Consider that the cutting width is about twice as much the tip diameter.
This position (grating) is suggested even for precision cuttings, on thin metal sheets
(thickness less than 6 mm): take off the spacer 11 and use contact cutting.
P-Tronic 100
P-Tronic 100
- 12 -
Summary of Contents for 40P
Page 2: ......
Page 23: ...GB English Instruction Manual P Tronic 40P 70 100 18 ELECTRIC WIRING DIAGRAM 19 P Tronic 40P...
Page 25: ...GB English Instruction Manual P Tronic 40P 70 100 20 ELECTRIC WIRING DIAGRAM P Tronic 70 21...
Page 28: ...GB English Instruction Manual P Tronic 40P 70 100 22 ELECTRIC WIRING DIAGRAM P Tronic 100 23...
Page 29: ......