background image

www.p-light.com

established 2000

Elektronics Maxi

Elektronic terminals

Terminal no. 

Description

1.  B24 V, connected to P-LIGHT battery.
2.  Battery Gnd (-), connected to P-LIGHT battery.
3.  Input  Gnd  (-)  negative/ground,  min  2.5  mm².  From  vehicle/

trailer hitch.

4.  Input +24 V “Lighting circuit 1”, min 2.5 mm². From the trailer’s 

hitch.

5.  Output  +24  V  “Lighting  circuit  1”,  connected  to  parking  and 

side lights which are to remain on while driving, and P-LIGHT 

for short-term parking.

  NOTE: Must not be connected to cabling connected to terminal 

4 or 6.

6.  Input +24 V “Lighting circuit 2”, min 2.5 mm². From the trailer’s 

hitch.

7.  Output  +24  V  “Lighting  circuit  2”,  connected  to  parking  and 

side lights which are to remain on while driving, and P-LIGHT 

for short-term parking.

  NOTE: Must not be connected to cabling connected to terminal 

4 or 6.

8.  Input  +24  V  “Option”.  (Direct  operation  to  terminal  9,  if,  for 

example,  you  connect  the  warning  light  to  terminal  9,  it’s 

possible  to  connect  the  trailer’s  reversing  circuit  here,  this 

activates the warning light when the vehicle reverses).

9.  24 V “Option” e.g. warning light, work lighting, etc. 

max. 200 W. Activated by push button 2.

10.  Output  +24  V  “AUX”.  Always  +24  V  even  if  the  truck  is  not 

connected, nor controlled by any pushbutton. Is intended for 

operation of e.g. external radio control, the cable is prepared 

up  to  the  rocker  switch  where  you  connect  the  required 

equipment. Max 200 W.

21 and 22. No function.
23. Input +24 V from pushbutton 2 “Option” (activates terminal 9).
24. 24 V to pushbutton 2 “Option” (activates terminal 9).
25. Input +24 V from pushbutton 1 “Parking” (activates terminals 5 

and 7).

26. 24 V to pushbutton 1 “Parking” (activates terminals 

5 and 7).

Elektronik plintar

Plint nr.  Beskrivning

1.  B24 V, connected to P-LIGHT battery.
2.  Battery Gnd (-), connected to P-LIGHT battery.
3.  Input  Gnd  (-)  negative/ground,  min  2.5  mm².  From  vehicle/

trailer hitch.

4.  Input +24 V “Lighting circuit 1”, min 2.5 mm². From the trailer’s 

hitch.

5.  Output  +24  V  “Lighting  circuit  1”,  connected  to  parking  and 

side lights which are to remain on while driving, and P-LIGHT 

for short-term parking.

  NOTE: Must not be connected to cabling connected to terminal 

4 or 6.

6. Input +24 V “Lighting circuit 2”, min 2.5 mm². From the trailer’s 

hitch.

7.  Output  +24  V  “Lighting  circuit  2”,  connected  to  parking  and 

side lights which are to remain on while driving, and P-LIGHT 

for short-term parking.

  NOTE: Must not be connected to cabling connected to terminal 

4 or 6.

8.   Input  +24  V  “Option”.  (Direct  operation  to  terminal  9,  if,  for 

example,  you  connect  the  warning  light  to  terminal  9,  it’s 

possible  to  connect  the  trailer’s  reversing  circuit  here,  this 

activates the warning light when the vehicle reverses).

9.   24 V “Option” e.g. warning light, work lighting, etc. 

max. 200 W. Activated by push button 2.

10. Output  +24  V  “AUX”.  Always  +24  V  even  if  the  truck  is  not 

connected, nor controlled by any pushbutton. Is intended for 

operation of e.g. external radio control, the cable is prepared 

up  to  the  rocker  switch  where  you  connect  the  required 

equipment. Max 200 W. Factory connected to terminal 31.

21 and 22. No function.
23. Input +24 V from pushbutton 2 “Option” (activates terminal 9).
24. 24 V to pushbutton 2 “Option” (activates terminal 9).
25. Input +24 V from pushbutton 1 “Parking” (activates terminals 

5 and 7).

26. 24 V to pushbutton 1 “Parking” (activates terminals 

5 and 7).

30.  Output  +24  V  to  momentary  rocker  switch  for  control  of 

solenoid or relay (factory connected from terminal 31).

31. 24 V to toggle switch for external radio control (factory 

connected from terminal 10).

32. 24 V to toggle switch to relay (factory connected from 

31).

  Note,  terminals  30,  31  and  32  are  monitored  by  voltage 

monitors,  and  one  of  these  must  always  be  used  for  the 

connection of equipment in order to prevent deep discharge of 

batteries and risks of damage to connected equipment due to 

excessively low voltage during operation.

34.  Ground  point  power  Gnd(-),  cable  dimension  after  power 

on  (Cable  to  the  negative  terminal  of  the  battery  is  factory 

mounted).

41. 24 V power (PTO), solenoid 100 A or relay 50 A.
42.  Connected  to  terminal  43  (main  power  switch,  factory 

connected).

43. Connected to terminal 42, (solenoid or relay).
44. Cable to battery’s positive terminal (+) (factory connected).
F1. Power fuse (PTO), solenoid 100 A or relay 60 A. If a small fuse is 

required adapt as required.

Elektronics Maxi XL STD

10

Summary of Contents for Maxi

Page 1: ...HyCover ngsg rden sv Installation och bruksanvisning 2 7 en Installation and Instructions for Use 8 13 de Installations und Betriebsanleitung 14 19 fi Asennus sa K ytt ohje 20 25 en Wiring diagram 26...

Page 2: ...g r att batterierna ska vara fullt uppladdade innan l ngre avst llning av sl pet trailern sker Vid mer n 1 m nads avst llning ska kabels kringen vid batterierna tas bort Garanti och funktion P LIGHT...

Page 3: ...terstart kr vs 5 minuters sp nning p plint 4 och 6 lastbilen tillkopplad och belysning p Om sp nningen i batterierna efter denna tid verstiger programmerad gr ns aktiveras plint 10 AUX igen Viktigt a...

Page 4: ...av P LIGHT vid korttidsparkering OBS F r inte vara ihopkopplad med kablage som r kopplat till plint 4 eller 6 6 In 24V Belysningskrets 2 min 2 5 mm Fr n sl pets kopplingshandske 7 Ut 24V Belysningskr...

Page 5: ...mm2 4 2 5 mm2 6 2 5 mm2 Ut 5 Max 100W 7 Max 100W 9 Max 200W 30 31 och 32 Max 200W 34 Jordpunkt kra PTO 41 Kra u ag PTO Solenoid max 100A eller Rel max 50A Ba erikapacitet 45Ah Sp nning 24V Laddning 10...

Page 6: ...9 25 In 24V fr n tryckknapp 1 Parkering aktiverar plint 5 och 7 26 Ut 24V till tryckknapp 1 Parkering aktiverar plint 5 och 7 30 Ut 24V momentan vippstr mbrytare f r styrning av solenoid 1 fr mre kap...

Page 7: ...i XL Maxi XL HyCover 58 R 58 L Kopplingsbox p sl p 31 AUX 32 30 Utg belysnings krets 1 Utg belysnings krets 2 58 R 58 L 9 6 4 7 5 3 Solenoid 1 och 2 Styrenhet 10A support p light com 3 InnoNet AB 2019...

Page 8: ...e fully charged before the trailer taken out of service for any length of time If it is to be taken out of service for more than 1 month the cable fuse at the batteries must be removed Warranty and fu...

Page 9: ...ing requires 5 minutes of voltage on terminals 4 and 6 truck connected and lighting on If the voltage in the batteries after this time exceeds the programmed limit terminal 10 AUX is activated again I...

Page 10: ...erm parking NOTE Must not be connected to cabling connected to terminal 4 or 6 6 Input 24 V Lighting circuit 2 min 2 5 mm From the trailer s hitch 7 Output 24 V Lighting circuit 2 connected to parking...

Page 11: ...58 L 9 6 4 7 5 3 Solenoid or Relay Control unit 10A U T R U S T N I N G Power outlets 3 VBG 15 pin ISO 12098 12 9 1 4 5 5 6 6 24V Gnd 58L 58R Cable area connec on P LIGHT In 3 2 5 mm2 4 2 5 mm2 6 2 5...

Page 12: ...Option activates terminal 9 25 Input 24 V from pushbutton 1 Parking activates terminals 5 and 7 26 Output 24 V to pushbutton 1 Parking activates terminals 5 and 7 30 Output 24 V momentary rocker switc...

Page 13: ...ver tarp coverage with P LIGHT Maxi XL Connection Maxi XL HyCover ngsg rden www p light com established 2000 46 581 80 300 Maxi XL HyCover 58 R 58 L Clutch box on trailer 31 AUX 32 30 58 R 58 L 9 6 4...

Page 14: ...lieger f r einen l ngeren Zeitraum abgestellt wird Betr gt die Abstelldauer mehr als 1 Monat muss die Kabelsicherung an den Batterien entfernt werden Gew hrleistung und Funktion F r P LIGHT bieten wir...

Page 15: ...C11 angezeigt F r den Neustart ist eine 5 min tige Spannung an Klemme 4 und 6 erforderlich Lkw angeschlossen und Beleuchtung eingeschaltet WenndieSpannungindenBatteriennachdieserZeit die programmiert...

Page 16: ...leuchten soll HINWEIS Darf nicht mit Kabeln verbunden sein die an Klemme 4 oder 6 angeschlossen sind 6 24 V Eingang Beleuchtungsstromkreis 2 mind 2 5 mm Vom Kupplungskopf des Anh ngers 7 24 V Ausgang...

Page 17: ...58 L 31 AUX 32 30 58 R 58 L 9 6 4 7 5 3 Solenoid or Relay Control unit 10A U T R U S T N I N G Power outlets 3 VBG 15 pin ISO 12098 12 9 1 4 5 5 6 6 24V Gnd 58L 58R Cable area connec on P LIGHT In 3 2...

Page 18: ...2 Option aktiviert Klemme 9 25 24 V Eingang von Drucktaste 1 Parken aktiviert Klemme 5 und 7 26 24 V Ausgang an Drucktaste 1 Parken aktiviert Klemme 5 und 7 30 24 V AusgangWippschalterzurSteuerungvonM...

Page 19: ...9 6 4 7 5 3 Solenoid 1 och 2 Control unit 10A support p light com 3 InnoNet AB 2019 We reserve the right to correct any printing errors and ypographical errors and reserve the right to make changes w...

Page 20: ...en tulee pidemm n seisokin ajan olla t yteen ladattuja Yli 1kk seisokin ajaksi tulee akkujen lataussulake poistaa Takuu ja toiminta P LIGHT my nt 1 vuoden tuotetakuun Takuua sioissa tulee noudattaa In...

Page 21: ...etason nasta 10 AUX sammuu ja n yt lle tulee ilmoitus C11 Uudelleenk ynnistys vaatii j nnitteen nastalle 4 ja 6 viiden minuutin ajaksi auto kytkettyn ja valot sytytettyin Jos akkujen j nnite t m n j l...

Page 22: ...a sek P LIGHTin toimesta lyhytaikaisessa pys k inniss HUOM Ei saa yhdist liittimien 4 tai 6 johtimiin 6 Tulo 24V Valaisinpiiri 2 min 2 5 mm2 Per vaunun pistokkeelta 7 L ht 24V Valaisinpiiri2 kytket np...

Page 23: ...S T N I N G Power outlets 3 VBG 15 pin ISO 12098 12 9 1 4 5 5 6 6 24V Gnd 58L 58R Cable area connec on P LIGHT In 3 2 5 mm2 4 2 5 mm2 6 2 5 mm2 Out 5 Max 100W 7 Max 100W 9 Max 200W 30 31 och 32 Max 20...

Page 24: ...24V painonappi 1 Pys k inti aktivoi liittimet 5 ja 7 26 L ht 24V painonappi 1 Pys k inti aktivoi liittimet 5 ja 7 30 L ht 24V vipukytkin solenoidille 1 Etupeite tehdaskytketty liittimelt 31 31 L ht 24...

Page 25: ...over 58 R 58 L Clutch box on trailer 31 AUX 32 30 58 R 58 L 9 6 4 7 5 3 Solenoid 1 och 2 Control unit 10A support p light com 3 InnoNet AB 2019 We reserve the right to correct any printing errors and...

Page 26: ...www p light com established 2000 Wiring diagram 26 25 23 GR 31 30A 30B 32A 32B A B D C Plintar i Terminal in P LIGHT Maxi XL Option Parking Gnd AUX 30A 32A...

Page 27: ...www p light com established 2000 Wiring diagram 27 25 23 GR 31 30A 30B 32A 32B A B D C Plintar i Terminal in P LIGHT Maxi XL Option Parking Gnd AUX 30B 30A 32A 32B F2 auto fuse 42 41...

Page 28: ...hout prior notification Manufacturer InnoNet AB Olv gen 7 SE 342 50 Vislanda Phone 46 472 483 83 www p light com www innonet se Mounted date Manufactory No Trailer Company City Country Sign Manufactor...

Reviews: