www.p-light.com
established 2000
Elektronics Maxi
Elektronic terminals
Terminal no.
Description
1. B24 V, connected to P-LIGHT battery.
2. Battery Gnd (-), connected to P-LIGHT battery.
3. Input Gnd (-) negative/ground, min 2.5 mm². From vehicle/
trailer hitch.
4. Input +24 V “Lighting circuit 1”, min 2.5 mm². From the trailer’s
hitch.
5. Output +24 V “Lighting circuit 1”, connected to parking and
side lights which are to remain on while driving, and P-LIGHT
for short-term parking.
NOTE: Must not be connected to cabling connected to terminal
4 or 6.
6. Input +24 V “Lighting circuit 2”, min 2.5 mm². From the trailer’s
hitch.
7. Output +24 V “Lighting circuit 2”, connected to parking and
side lights which are to remain on while driving, and P-LIGHT
for short-term parking.
NOTE: Must not be connected to cabling connected to terminal
4 or 6.
8. Input +24 V “Option”. (Direct operation to terminal 9, if, for
example, you connect the warning light to terminal 9, it’s
possible to connect the trailer’s reversing circuit here, this
activates the warning light when the vehicle reverses).
9. 24 V “Option” e.g. warning light, work lighting, etc.
max. 200 W. Activated by push button 2.
10. Output +24 V “AUX”. Always +24 V even if the truck is not
connected, nor controlled by any pushbutton. Is intended for
operation of e.g. external radio control, the cable is prepared
up to the rocker switch where you connect the required
equipment. Max 200 W.
21 and 22. No function.
23. Input +24 V from pushbutton 2 “Option” (activates terminal 9).
24. 24 V to pushbutton 2 “Option” (activates terminal 9).
25. Input +24 V from pushbutton 1 “Parking” (activates terminals 5
and 7).
26. 24 V to pushbutton 1 “Parking” (activates terminals
5 and 7).
Elektronik plintar
Plint nr. Beskrivning
1. B24 V, connected to P-LIGHT battery.
2. Battery Gnd (-), connected to P-LIGHT battery.
3. Input Gnd (-) negative/ground, min 2.5 mm². From vehicle/
trailer hitch.
4. Input +24 V “Lighting circuit 1”, min 2.5 mm². From the trailer’s
hitch.
5. Output +24 V “Lighting circuit 1”, connected to parking and
side lights which are to remain on while driving, and P-LIGHT
for short-term parking.
NOTE: Must not be connected to cabling connected to terminal
4 or 6.
6. Input +24 V “Lighting circuit 2”, min 2.5 mm². From the trailer’s
hitch.
7. Output +24 V “Lighting circuit 2”, connected to parking and
side lights which are to remain on while driving, and P-LIGHT
for short-term parking.
NOTE: Must not be connected to cabling connected to terminal
4 or 6.
8. Input +24 V “Option”. (Direct operation to terminal 9, if, for
example, you connect the warning light to terminal 9, it’s
possible to connect the trailer’s reversing circuit here, this
activates the warning light when the vehicle reverses).
9. 24 V “Option” e.g. warning light, work lighting, etc.
max. 200 W. Activated by push button 2.
10. Output +24 V “AUX”. Always +24 V even if the truck is not
connected, nor controlled by any pushbutton. Is intended for
operation of e.g. external radio control, the cable is prepared
up to the rocker switch where you connect the required
equipment. Max 200 W. Factory connected to terminal 31.
21 and 22. No function.
23. Input +24 V from pushbutton 2 “Option” (activates terminal 9).
24. 24 V to pushbutton 2 “Option” (activates terminal 9).
25. Input +24 V from pushbutton 1 “Parking” (activates terminals
5 and 7).
26. 24 V to pushbutton 1 “Parking” (activates terminals
5 and 7).
30. Output +24 V to momentary rocker switch for control of
solenoid or relay (factory connected from terminal 31).
31. 24 V to toggle switch for external radio control (factory
connected from terminal 10).
32. 24 V to toggle switch to relay (factory connected from
31).
Note, terminals 30, 31 and 32 are monitored by voltage
monitors, and one of these must always be used for the
connection of equipment in order to prevent deep discharge of
batteries and risks of damage to connected equipment due to
excessively low voltage during operation.
34. Ground point power Gnd(-), cable dimension after power
on (Cable to the negative terminal of the battery is factory
mounted).
41. 24 V power (PTO), solenoid 100 A or relay 50 A.
42. Connected to terminal 43 (main power switch, factory
connected).
43. Connected to terminal 42, (solenoid or relay).
44. Cable to battery’s positive terminal (+) (factory connected).
F1. Power fuse (PTO), solenoid 100 A or relay 60 A. If a small fuse is
required adapt as required.
Elektronics Maxi XL STD