2. Çàìåíà ìàñëà
Air compressor
MAINTENANCE
1. Air Filter Change
Unscrew the screws of the protective casing to carry out compressor maintenance. After that,
clean the intake filter. This procedure should be performed depending on the state of the environ-
ment, but not less than every 100 hours of operation. If necessary, replace the filter element (a
clogged filter increases compressor wear).
2. Oil Change
Change oil after the first 100 hours of operation, and then every 300 hours. It is necessary to
periodically check the oil level upon completion of work and drain the condensate that has accu-
mulated inside the receiver, thereby protecting the instrument from corrosion.
3. Condensate Draining
It is necessary regularly, at least once a week, to drain condensate from the receiver, which accu-
mulates in the receiver during the operation of the compressor.
Compressor should be served by qualified personnel of the authorized service
centers only.