background image

 

 

To replace an ozone plate: 
 

1. Switch off the device, and disconnect it from the socket. 
2. Use a screwdriver to loosen the cover screw, and remove the 

cover. 

3. Pull the ceramic plate out of the ozone generator module. 
4. Install the ceramic plate as illustrated in the picture above 

(make sure that the plate does not fall). 

 

 

Summary of Contents for BLUE 7000

Page 1: ...Read the instructions carefully before using this device BLUE 7000 HE 141D COMMERCIAL OZONE GENERATOR USER MANUAL Read the instructions carefully before using this device ...

Page 2: ...he respiratory tract CAUTION DANGER OF INJURY BY ELECTRIC CURRENT WHEN OPENING THE DEVICE CAUTION WARNING DO NOT REMOVE THE COVER OR ANY EXTERNAL SERVICE PARTS DANGER OF INJURY BY ELECTRIC CURRENT FOR SERVICING CONTACT QUALIFIED SERVICE PERSONNEL The lightning bolt means that uninsulated material inside the unit can cause injury by electric current For everyone s safety do not remove the product s...

Page 3: ...one is deliberately manufactured for various industrial purposes it is produced naturally from oxygen by ultraviolet radiation electric discharge e g at high altitudes or lightning Ozone itself is a visibly blue gas which is approximately one and a half times as heavy as air density of 2 144 g l Ozone cannot be stored or transported in containers because it decomposes spontaneously in the presence...

Page 4: ... HE 141D Input voltage AC 220 240V 50 60Hz Energy consumption 100 W Number of ozone plates 90 x 50 mm 2 pcs Air volume Maximum 100 CFM 2 8 M3 min Active oxygenation 3 5 7 0 g h Noise level 45 dB Dimensions 260 x 210 x 180 mm Weight 2 9 Kg 3 ...

Page 5: ...tion timer Used to set the device s operating period ozone production for up to 3 hours Switching between low and high output High output at 7 000 mg low output at 3 500 mg Operation indicator Illuminated if the device is operating producing ozone 4 ...

Page 6: ... rear view USE Fuse A replaceable fuse 1A length 0 79 inches is located here Power supply Power supply connector 220V 240V 5 ...

Page 7: ...or remove from the area which is to be cleaned all objects which meet these criteria or if you are unsure of their resistance or they are objects of a higher or artistic value You can only enter the room 1 hour after the device stops operating FOLLOW THESE STEPS 1 Close the space which is to be cleaned 2 No people animals or plants may be present in the room during cleaning 3 Place the device as c...

Page 8: ... that the ozone generator is properly earthed in order to prevent injury by electric current The fuse is installed correctly and in a good condition When replacing the fuse pull out the plastic fuse holder take out the old fuse and insert the new one The replacement fuse must be 1 ampere 0 79 inches See the picture below Caution You should not try to remove the unit cover because there are no part...

Page 9: ...be replaced They are normally changed after 6 000 hours of operation WARNING The warranty does not apply to the parts of the unit which require replacement during normal use To damage or faults caused by negligence misuse or use which is not in accordance with the user manual The same applies to any defects or damage caused by unauthorised servicing 8 ...

Page 10: ...sconnect it from the socket 2 Use a screwdriver to loosen the cover screw and remove the cover 3 Pull the ceramic plate out of the ozone generator module 4 Install the ceramic plate as illustrated in the picture above make sure that the plate does not fall 9 ...

Page 11: ...10 ...

Page 12: ...11 ...

Page 13: ...Read the instructions carefully before using this device BLUE 7000 HE 141D COMMERCIAL OZONE GENERATOR USER MANUAL Read the instructions carefully before using this device Version 20 05 2020 12 ...

Reviews: