2. CONTROLS
3. CALIBRATION
OPERATION
Switching On and Off
Mode Selection
Detection Button
1 To turn the unit on, press the
on/off Button
The directional mode buttons
allows you to select between the
4 operational modes.
Note:
An arrow is displayed at
the bottom of the digital display,
indicating the current mode.
Stud detection mode:
For metallic and non-metallic materials (wood, metal, etc.)
• Wood max. detection depth:
19mm
• Metal max. detection depth:
19mm
Metal detection mode:
For ferrous materials and copper piping
• Ferrous Metal max. detection depth:
50mm
• Copper max. detection depth:
24mm
Deep detection mode:
For copper piping, metal, wood
• Wood max. detection depth:
19mm
• Metal max. detection depth:
38mm
• Copper max. detection depth:
38mm
AC detection mode:
For live cables (power cords, network cables, etc.)
• Max. detection depth:
50mm
1 The detection button is used
to calibrate and start detecting
objects.
The stud detector needs to be calibrated for the characteristics of the
search area before each measurement.
Note:
Calibrations needs to be repeated every 60 seconds in order to
reduce the occurrence of measuring errors.
1 Turn the unit on by pressing
the on/off button.
3 Select an area of the surface
that is less likely of finding
the material you are trying to
locate.
2 Hold the back of the stud
detector against the surface.
4 Press and hold the detection
button to allow the detector
to calibrate correctly. The
calibration is complete when
you hear 3 beeps.
2 To turn the unit off, press the
on/off button again.
Note:
The unit will automatically
turn off after 60 seconds of
inactivity.
STUD METAL DEEP AC
STUD METAL DEEP AC
STUD METAL DEEP AC
STUD METAL DEEP AC
STUD METAL DEEP AC