background image

2.  CONTROLS

3.  CALIBRATION

OPERATION

Switching On and Off

Mode Selection

Detection Button

1   To turn the unit on, press the 

on/off Button

The directional mode buttons 

allows you to select between the 

4 operational modes.

Note:

 An arrow is displayed at 

the bottom of the digital display, 

indicating the current mode.

Stud detection mode:

 

For metallic and non-metallic materials (wood, metal, etc.)

• Wood max. detection depth: 

 

19mm

• Metal max. detection depth: 

 

19mm

Metal detection mode:

 

For ferrous materials and copper piping 

• Ferrous Metal max. detection depth:   

50mm

• Copper max. detection depth: 

 

24mm

Deep detection mode:

 

For copper piping, metal, wood

• Wood max. detection depth: 

 

19mm

• Metal max. detection depth: 

 

38mm

• Copper max. detection depth: 

 

38mm

AC detection mode:

 

For live cables (power cords, network cables, etc.)

• Max. detection depth: 

 

 

50mm

1   The detection button is used 

to calibrate and start detecting 

objects.

The stud detector needs to be calibrated for the characteristics of the 

search area before each measurement.

Note:

 Calibrations needs to be repeated every 60 seconds in order to 

reduce the occurrence of measuring errors.

1   Turn the unit on by pressing 

the on/off button.

3   Select an area of the surface 

that is less likely of finding 

the material you are trying to 

locate.

2   Hold the back of the stud 

detector against the surface.

4   Press and hold the detection 

button to allow the detector 

to calibrate correctly. The 

calibration is complete when 

you hear 3 beeps.

2   To turn the unit off, press the 

on/off button again.

Note: 

The unit will automatically 

turn off after 60 seconds of 

inactivity. 

STUD  METAL  DEEP  AC

STUD  METAL  DEEP  AC

STUD  METAL  DEEP  AC

STUD  METAL  DEEP  AC

STUD  METAL  DEEP  AC