background image

0

25

50

75

100

125

150

0

(1)00

(3)00

(5)00

(7)00

(9)00

2

4

6

8

10

Lb/in²

(PSI)

kPA

(BAR)

PRESSURE GAUGE

kg/cm²

0

25

50

75

100

125

150

0

(1)00

(3)00

(5)00

(7)00

(9)00

2

4

6

8

10

Lb/in²

(PSI)

kPA

(BAR)

PRESSURE GAUGE

kg/cm²

AIR COMPRESSOR

1.0HP 24L 

SILENT

LOW MAINTENANCE

OIL FREE

TECHNOLOGY

AIR COMPRESSOR

1.0HP 24L 

SILENT

1.  Safety Valve

2.  Air Filter

3.  Motor

4.  On/Off Switch

5.  Tank Pressure Gauge

6.  Pressure Regulator

7.  Carry Handle

8.  Regulated Pressure Outlet

9.  Output Pressure Gauge

10. Support Foot

11. Drain Valve

12. Pressure Tank

13. Wheel

24L SILENT OIL FREE AIR COMPRESSOR

KNOW YOUR PRODUCT

1. ASSEMBLY

SETUP & PREPARATION

2

1

3

4

5

6

7

8

9

10

11

13

12

ONLINE MANUAL

Scan this QR Code with your mobile 

device to take you to the online manual.

The compressor is intended to be used for pneumatic tools with 

low air consumption, such as tyre pump nozzles, blower nozzles 

and paint guns. The compressor is not suitable for tools with a 

high air consumption, such as grinders or impact wrenches. 

Pre-Setup Checks

•   Examine the machine for signs of transit damage. If damaged, 

do not use, return to place of purchase 

•   The compressor should be set up near to the user.

•   Avoid long air lines and long supply lines (extensions).

•   Make sure the intake air is dry and dust-free.

•   Do not set up the compressor in damp or wet rooms. The 

compressor is designed to be used in dry rooms. It is prohibited 

to use the compressor in areas where work is conducted with 

sprayed water. 

•   Before you use the machine, make sure that the mains voltage 

complies with the specifications on the rating plate. 

•   The compressor may only be used in suitable areas (with good 

ventilation and an ambient temperature from 5°C to 40°C). 

There must be no dust, acids, vapours, explosive or flammable 

gases in the room.

WARNING! 

ENSURE THE TOOL IS TURNED OFF AND 

DISCONNECTED FROM THE POWER SUPPLY BEFORE 

PERFORMING ANY OF THE FOLLOWING OPERATIONS.

Summary of Contents for SAC-2110

Page 1: ...rm maintenance as set out within the instruction manual If the tool is disassembled or tampered with in any way Professional industrial or high frequency use WARRANTY Ozito Industries Pty Ltd 25 Fox Drive Dandenong South Victoria Australia 3175 ozito com au 24L Silent Air Compressor 2 x Wheels 2 x Large Bolts 4 x Large Washers 2 x Large Spring Washers 2 x Large Nuts Air Filter Support Foot Small B...

Page 2: ...zzles blower nozzles and paint guns The compressor is not suitable for tools with a high air consumption such as grinders or impact wrenches Pre Setup Checks Examine the machine for signs of transit damage If damaged do not use return to place of purchase The compressor should be set up near to the user Avoid long air lines and long supply lines extensions Make sure the intake air is dry and dust ...

Page 3: ...peat steps 2 3 pushing the Nitto connector firmly into the outlet Disconnecting Air Tools WARNING ENSURE YOU HAVE A FIRM GRIP ON THE AIR HOSE WHEN DISCONNECTING IT FROM THE AIR COMPRESSOR AS PRESSURISED AIR IN THE TANK MAY CAUSE IT TO WHIP AROUND AND INFLICT INJURY OR DAMAGE 1 To remove an air tool from the unit retract the sleeve on the female Nitto fitting and disconnect the air hose from the ai...

Page 4: ...tart up the unit has overloaded and the thermal protection has activated If the thermal protection activates switch off the compressor and allow the compressor to cool down for 15 minutes Before attempting to restart the compressor check that the air filter is not blocked Refer to the Maintenance section to clean the air filter WARNING ALLOW THE AIR COMPRESSOR TO COOL BEFORE ATTEMPTING ANY MAINTEN...

Page 5: ...ILENT LOW MAINTENANCE OIL FREE TECHNOLOGY 0 25 50 75 10 0 125 15 0 0 1 00 3 00 5 00 7 00 9 00 2 4 6 8 10 Lb in PSI kPA BAR PRESSURE GAUGE kg cm 0 25 50 75 10 0 125 15 0 0 1 00 3 00 5 00 7 00 9 00 2 4 6 8 10 Lb in PSI kPA BAR PRESSURE GAUGE kg cm AIR COMPRESSOR 1 0HP 21L SILENT LOW MAINTENANCE OIL FREE TECHNOLOGY 0 25 50 75 10 0 125 15 0 0 1 00 3 00 5 00 7 00 9 00 2 4 6 8 10 Lb in PSI kPA BAR PRESS...

Page 6: ...ound 3bar 3 Unscrew the lid of the air filter 4 Remove the paper filter from the housing tap it and spray it with the blow gun to remove any dirt Re insert it into the housing 5 Re attach the lid 0 25 50 75 10 0 125 15 0 0 1 00 3 00 5 00 7 00 9 00 2 4 6 8 10 Lb in PSI kPA BAR PRESSURE GAUGE kg cm 0 25 50 75 10 0 125 15 0 0 1 00 3 00 5 00 7 00 9 00 2 4 6 8 10 Lb in PSI kPA BAR PRESSURE GAUGE kg cm ...

Page 7: ...R CARRYING OUT ANY MAINTENANCE PROCEDURE MAKE SURE THAT IT IS DISCONNECTED FROM THE POWER SUPPLY TO PREVENT ACCIDENTAL STARTING No protection against ingress from water lP20 Sound Power Level Wear hearing eye and breathing protection Warning Regulatory Compliance Mark RCM V Volts Hz W Hertz n0 min Alternating Current Watts No load speed Revolutions or reciprocations per minute psi L min Pounds per...

Page 8: ...t of a person s body Do not attempt to block the air outlet with your finger or any part of your body The tool must be used only for its prescribed purpose Any use other than those mentioned in this Manual will be considered a case of misuse The user and not the manufacturer shall be liable for any damage or injury resulting from such cases of misuse The manufacturer shall not be liable for any ch...

Reviews: