background image

PXHDIS-240

AIR IN

6.  INFLATING HIGH VOLUME ITEMS

The high volume air hose can be used to inflate high volume items by 

connecting to the air outlet, or deflate high volume items by connecting to the 

air inlet.
An example of a high volume item is an air mattress or pool toy.

The high pressure air hose can be used to inflate high pressure items such as 

car and bike tyres or sporting equipment.

WARNING!

 

ENSURE THE INFLATOR INLET IS NOT 

BLOCKED DURING INFLATION OR THE OUTLET IS 
NOT BLOCKED DURING DEFLATION.

WARNING!

 

AVOID INFLATING THE OBJECT ABOVE 

THE RECOMMENDED INFLATION PRESSURE. THIS 
MAY LEAD TO DAMAGE AND/OR INJURIES.

5.  INFLATING HIGH PRESSURE ITEMS

Inflating

Deflating

1   Attach the required inflation 

adaptor to the high pressure hose 

and secure using the locking lever.

3   Press the operating mode switch 

into “II” position to start inflating 

the high volume item.

1   Remove the high volume air 

hose from the housing and 

attach to the outlet port.

1   Remove the high volume air 

hose from the housing and 

attach to the inlet port.

3   Adjust the target pressure 

using the “+” and “-” pressure 

adjustment buttons.

Note: 

The required pressure should 

be written on the item.

5   Once the preset pressure is 

reached, the tool will automatically 

shut-off. 

After the tool has automatically 

shut off, press the operation mode 

switch into the off position “0”.

2   Insert / attach the hose 

adaptor to the item to be 

inflated.

4   Once the item is completely 

inflated, press the operation 

mode switch into the off 

position “0”.

2   Insert the adaptor into the 

inflatable item.

Note:

 If the inflatable item 

has a cap or air lock, ensure it is 

removed or unlocked to allow air 

to flow into the item.

4  Press the operating mode 

switch into “I” position to start 

inflating the high pressure item.

Note:

 For sporting equipment due to the small size and low pressure, the 

inflator may automatically cut-off prior to reaching the desired pressure. In 

this case, cycle the unit on and off until the required pressure is reached.

AC

DC

I

0

I

+

MODE

I

a

b

AC

DC

I

0

I

+

MODE

I

a

b

AC

DC

I

0

I

+

MODE

I

a

b

AC

DC

I

0

I

+

MODE

I

a

b

AIR IN

AC

DC

I

0

I

+

MODE

I

a

b

AC

DC

I

0

I

+

MODE

I

a

b

Summary of Contents for PXHDIS-240

Page 1: ...ure and for compensation for any other reasonably foreseeable loss or damage You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure Generally you will be responsible for all costs associated with a claim under this warranty however where you have suffered any additional direct loss as a result of...

Page 2: ...ing Battery is charging low charge RED Illuminated Battery is charging mid charge GREEN Illuminated Battery is fully charged BOTH Illuminated Battery pack is too hot or too cold charging will begin automatically when battery reaches correct charging temperature BOTH Flashing Defective battery Never charge a defective battery pack Remove battery pack from charger 1 BATTERY CHARGING sold separately ...

Page 3: ...hing Stand By no battery pack is inserted RED Illuminated Battery is charging low charge GREEN Illuminated Battery is fully charged RED Flashing Battery or Charger fault RED GREEN Flashing Battery pack is too hot or too cold remove battery from charger and store at room temperature 20ºC Insert battery again when at correct charging temperature If this happens again the battery is defective and nee...

Page 4: ...lating a high pressure item the current pressure will be displayed on the digital display Note When using the inflator to inflate or deflate a high volume item the digital display will show 0 00 2 Increase the preset pressure using the button or decrease the pressure using the button The preset pressure will be displayed on the digital display as it is adjusted 1 To change between the 3 pressure m...

Page 5: ...emove the high volume air hose from the housing and attach to the inlet port 3 Adjust the target pressure using the and pressure adjustment buttons Note The required pressure should be written on the item 5 Once the preset pressure is reached the tool will automatically shut off After the tool has automatically shut off press the operation mode switch into the off position 0 2 Insert attach the ho...

Page 6: ...lator is not operating at full capacity Possible clogging Ensure the air inlet is not blocked when inflating a high volume item Ensure the air outlet is not blocked when deflating a high volume item Loose hose of adaptor Ensure the hose or inflation adaptor is fitted securely Motor stops while inflating Battery has no power Charge battery High pressure item has reached preset pressure The inflator...

Page 7: ...ssembly may result in a risk of electric shock electrocution or fire 9 To reduce risk of electric shock unplug the charger from the outlet before attempting any cleaning Removing the battery pack will not reduce this risk 10 Never attempt to connect 2 chargers together 11 DO NOT store or use the tool and battery pack in locations where the temperature may reach or exceed 40ºC such as inside sheds ...

Page 8: ...ose clothes jewellery or long hair can be caught in moving parts g If devices are provided for the connection of dust extraction and collection facilities ensure these are connected and properly used Use of dust collection can reduce dust related hazards 4 Power tool use and care a Do not force the power tool Use the correct power tool for your application The correct power tool will do the job be...

Reviews: