4.  SETUP

5. OPERATE

1.   Ensure the outlet hose is connected correctly.

2.   Ensure the distance from the surface of the water to the 

highest point that you wish to deliver the water does not 

exceed 8 metres.

WARNING!:

 NEVER CARRY, LIFT OR PULL UP 

THE PUMP BY THE POWER CORD. THIS WILL 

DAMAGE THE UNIT.

WARNING!:

 YOUR PUMP HAS THE CAPACITY 

TO PUMP DIRTY WATER WITH A  NON SOLID 

PARTICLE SIZE OF UP TO 15MM IN DIAMETER.  

1.   Immerse the pump in the 

water. For deep water, 

use a rope (not included) 

and secure it to the 

handle. Set the pump 

in the desired position 

within the work area or 

tank.

2.   Insert the plug into the 

mains power socket. 

Where possible avoid 

using extension cords 

as this can lead to a 

voltage drop which may 

cause power loss and 

overheating. Switch 

on the mains power to 

operate pump.

3.   To stop operation, turn off the mains power. The pump 

will also stop operation automatically once the float switch 

reaches the minimum water depth.

Priming

When immersed and ON the pump will need to prime and 

purge the air inside the pump before water flows at the 

outlet. This can take up to 20 seconds. If operating the pump 

manually tilting the pump to 

allow some air to escape from 

the base can help.

Air also escapes from the 

Air Bleed Valve. When 

pumping, the water 

pressure will shut this valve 

off.

WARNING!

 

THIS PUMP MUST BE USED WITH 

RESIDUAL CURRENT DEVICE RATED 30mA OR 

LESS.

Before starting, perform a few simple checks:

3.   Adjust the float switch adjustor to allow the pump to switch on 

and off at the desired water height.

4.  Ensure that the container is large enough to allow the float 

switch to move freely and function effectively, a minimum area 

of 50x50x50cm is required.

5.  Ensure the pump is placed on a flat and level surface, there 

are no obstructions to the suction base and it is clear of mud 

or sediment.

WARNING!:

 THIS PRODUCT IS INTENDED 

FOR PUMPING WATER IN A HOME DOMESTIC 

APPLICATION. DO NOT USE IT FOR 

CORROSIVE, ABRASIVE, EXPLOSIVE OR 

DANGEROUS LIQUIDS.

MAX. 

HEAD 8M

MAX. 

IMMERSION 

DEPTH 5M

DISCHARGE POINT

POWE

R

CAB

LE: 

10M

WATER LEVEL

FLOAT

SWITCH

WATER CONTAINER

OUT

LET

 HO

SE

OPERATION

WARNING!:

 BEFORE SUBMERGING THE PUMP 

IN WATER, UNWRAP THE POWER CORD AND 

ENSURE THE PLUG IS CLEAR OF ANY DAMP 

LOCATIONS.

WARNING!:

 THE PUMP MUST NOT BE USED 

WHEN PEOPLE ARE IN THE WATER.

Summary of Contents for PSDWV-500

Page 1: ...efects caused by or resulting from abuse accidents or alterations Failure to perform maintenance as set out within the instruction manual If the tool is disassembled or tampered with in any way WARRANTY TO ENSURE A SPEEDY RESPONSE PLEASE HAVE THE MODEL NUMBER AND DATE OF PURCHASE AVAILABLE A CUSTOMER SERVICE REPRESENTATIVE WILL TAKE YOUR CALL AND ANSWER ANY QUESTIONS YOU MAY HAVE RELATING TO THE W...

Page 2: ...CESSORIES ASSEMBLY 1 Screw a Hose Adaptor into the pump housing by rotating in a clockwise direction 10 WARNING ENSURE THE PUMP IS DISCONNECTED FROM THE POWER SUPPLY BEFORE PERFORMING ANY OF THE FOLLOWING ASSEMBLY 2 Securely attach the hose tube pipe to the Hose Adaptor fit hose clamps not included if you are using flexible hose or tube and tighten well NOTE The maximum pumping rate is possible on...

Page 3: ...et the pump to switch off at a higher water level adjust the float switch cable length in the adjuster 4 When the float switch cable is extended fully the pump will function down to a water depth of 50mm and automatically shut off 300 300 300 100mm minimum WARNING MAKE SUR THAT THE FLOAT SWITCH DOES NOT TOUCH THE BOTTOM BEFORE SWITCHING OFF TO AVOID THE RISK OF RUNNING DRY The pump float switch ca...

Page 4: ... water flows at the outlet This can take up to 20 seconds If operating the pump manually tilting the pump to allow some air to escape from the base can help Air also escapes from the Air Bleed Valve When pumping the water pressure will shut this valve off WARNING THIS PUMP MUST BE USED WITH RESIDUAL CURRENT DEVICE RATED 30mA OR LESS Before starting perform a few simple checks 3 Adjust the float sw...

Page 5: ...ts Incorrect assembly leads to air and water leakage in the discharge lines Clean the suction base of any foreign matter and debris Remove the obstructions Check the suction line connections for air leaks and tighten or fix where found Ensure the discharge lines are the correct length and all assembly instructions are adhered to Pump will not turn off even though the water level is low The float s...

Page 6: ...viced by a qualified repair person using only identical replacement parts This will ensure that the safety of the pump is maintained b If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard GENERAL POWER TOOL SAFETY WARNINGS ELECTRICAL SAFETY WARNING This product is intended for pumping water in a Home Domes...