2. FLOAT SWITCH
3. MANUAL MODE
PREPARATION
The pump is fitted with a float switch, which controls how the
pump switches on and switches off automatically. 200mm of
water is the pumps lowest starting level.
30
0
30
0
NOTE:
There must be a
minimum of 100mm of cable
from the adjuster to the float.
30
0
30
0
1. When the float switch is
about 30° higher than
horizontal (start up level)
or above the handle, the
pump will turn ‘on’ and
operate (water depth of
500mm).
2. When the float switch is 30°
lower than the horizontal or
below the handle, the pump
will turn ‘off’. (water depth of
approximately 150mm).
30
0
30
0
3. To set the pump to switch
off at a higher water level,
adjust the float switch cable
length in the adjuster.
4. When the float switch cable
is extended fully the pump
will function down to a
water depth of 50mm and
automatically shut off.
30
0
30
0
30
0
30
0
100mm
minimum
WARNING!
MAKE SUR THAT THE FLOAT SWITCH DOES
NOT TOUCH THE BOTTOM BEFORE SWITCHING OFF
TO AVOID THE RISK OF RUNNING DRY.
The pump float switch can also function in manual mode
which allows the pump to continually operate regardless of
the water level.
30
0
30
0
1. When the float switch
is held in the vertical
position the pump will run
continuously.
WARNING!
TO PREVENT THE PUMP RUNNING DRY,
THIS OPERATION MODE IS ONLY ALLOWED UNDER
SUPERVISION. THE PUMP MUST BE SWITCHED OFF
AS SOON AS NO MORE WATER IS EMITTED FROM THE
DISCHARGE LINE.