background image

INSTALLATION

TROUBLESHOOTING

Discharge point

Max. 

head:

 

8m

Max. 

immersion 

depth: 7m

Water level

Pump

Water container

Power cable: 10m

Problem

Possible Cause

Solution

 

The pump does not start,  

or pump water

 

Pump is not connected to the power supply 

 

Float switch has not been activated, water 

level too low 

The impellor is stuck
 

The thermal overload protection is activated 

 

The motor is damaged

 

Check that the pump is connected to the mains power supply 

 

Manually raise the position of the float switch 
 

Turn pump off and inspect and clean obstruction
 

Wait for the motor to cool and it will automatically start operation  

 

Contact Ozito customer service

 

The pump does not supply water 

when the motor is running

 

The suction base is obstructed/blocked 

Air lock in the hose/tube and/or pump (air 

bubbles) 

Discharge hose/tube (not included) is kinked  

damaged or blocked.

 

Clean the suction base of any foreign matter and debris 

 

Perform several start-ups in order to remove all the air or lift and tilt the pump slightly while the 

pump is running 

Un-kink the discharge hose/tube. Or replace hose/tube 

Disconnect the mains power and check the discharge outlet for any foreign matter

 

The pump flow rate is reduced

 

The max head / immersion is exceeded 

 

The suction base is partially obstructed/

blocked 

 

The hose/tube is obstructed 

 

Air leak in the suction line or joints 

Incorrect assembly leads to air and water 

leakage in the discharge lines

 

Reduce below the max head / immersion rating. 

 

Clean the suction base of any foreign matter and debris 

 

 

Remove the obstructions 

 

Check the suction line connections for air leaks and tighten or fix where found 

 

Ensure the discharge lines are the correct length and all assembly instructions are adhered to

 

Pump will not turn off, even 

though the water level is low

 

The float switch is stuck in the “on” position 

 

Ensure that the float switch is free to operate normally. Contact Ozito customer service if the 

problem still occurs 

Hose/tube does not stay on the 

universal adaptor when water is 

travelling through

The hose/tube is slightly wider than the 

dimension of the universal adaptor

An adhesive can be used inside the hose/tube to prevent this or Teflon tape can be fixed 

around the universal adaptor or a hose clamp can be used

The pump operates intermittently

The suction base is obstructed/blocked 

 

Incorrect voltage is being used 

 

The fluid contains particles thicker than 35mm 

 

The motor is faulty or damaged 

 

Water level is below 50mm

 

Clean the suction base of any foreign matter and debris 

 

Ensure the pump is connected into 230-240V power supply 

 

Ensure the pump is not being used with particles thicker than 35mm. 

 

Contact Ozito customer service 

 

Ensure the water level is above 50mm