3. When the float switch is
about 30° higher than
horizontal (start up level) or
above the handle, the pump
will turn ‘on’ and operate
(water depth of 500mm)
4. When the float switch is 30°
lower than the horizontal or
below the handle, the pump
will turn ‘off’. (water depth of
approximately 150mm)
2. To set the pump to switch off
at a higher water level, insert
the float switch cable into
the adjuster
NOTE:
There must be a
minimum of 100mm of cable
from the adjuster to the float.
1 When the float switch cable
is able to move freely the
pump will function down to
a water depth of 50mm and
automatically shut off
2. L-SHAPE CONNECTOR
3. FLOAT SWITCH
3. Screw the prepared
universal adaptor clockwise
onto the L-shape connector.
NOTE.
The hose/tube/
tap adaptor should not be
connected at this stage.
4. Securely attach the hose/
tube/tap adaptor to the
universal adaptor, fit hose
clamps if you are using
flexible hose or tube, and
tighten well.
2. Make sure the L-shape
connector is firmly
tightened so that the
O-ring is compressed
between the pump
housing and the
L-shape connector.
This ensures no leakage
will occur at this point.
OPERATION
The pump is fitted with a float switch, which controls how
the pump switches on and switches off.
1. Screw the L-shape
connector into the pump
housing by rotating in a
clockwise direction.
PUSH
100mm
minimum
30°
30°