Installing Batteries

The multimeter requires a 9V DC battery to operate.

1.  Unscrew the two screws 

on the back of the unit 

with a PH00 Phillips head 

screwdriver.

2.  Remove the back cover of the unit and attach a 9V battery to the 

battery flap.

3.  Tuck the battery into the compartment, replace the back cover of 

the unit and the 2 screws.

Low Battery Indicator

When the low battery icon 

appears, the batteries are at low 

charge and need to be replaced.

WARNING! 

TO AVOID FALSE READINGS, WHICH 

COULD LEAD TO ELECTRIC SHOCK OR PERSONAL 

INJURY, REPLACE THE BATTERY AS SOON AS THE 

LOW BATTERY ICON APPEARS.

1.  ½ Digit
2.  3½ Digit Display
3.  Voltage (AC) Range
4.  Mode Dial
5.  Current (DC) Range
6. 

Diode/Continuity Check

7.  Red Test Probe
8.  Black Test Probe
9.  ‘10A’ Port

10. 

‘VmAΩ’ Port

11. ‘COM’ Port
12. Black Test Lead
13. Red Test Lead
14. Resistance Range
15. Voltage (DC) Range
16. Low Battery Icon
17. Negative ‘-’ Reading 
18. High Voltage Icon

DIGITAL MULTIMETER

KNOW YOUR PRODUCT

1. ASSEMBLY

SETUP & PREPARATION

A

V

~

300

300

20

200

200

2

200m

Ω

OFF

200

200µ

20µ

2k

20k

200k

200m

20m

2m

2M

10A

VmA

Ω

V

10A

COM

1

9

10

11

12

13

2

7

4

3

5

6

18

8

16

17

15

14

WARNING! 

ENSURE THE UNIT IS IN THE OFF 

POSITION AND THE TEST LEADS HAVE BEEN 

REMOVED BEFORE OPENING THE BACK COVER.

Summary of Contents for ODMM-300

Page 1: ... personal injury b U se personal protective equipment Always wear eye protection Protective equipment such as dust mask non skid safety shoes hard hat or hearing protection used for appropriate conditions will reduce personal injuries c P revent unintentional starting Ensure the switch is in the off position before connecting to power source and or battery pack picking up or carrying the tool Carr...

Page 2: ...ge and need to be replaced WARNING TO AVOID FALSE READINGS WHICH COULD LEAD TO ELECTRIC SHOCK OR PERSONAL INJURY REPLACE THE BATTERY AS SOON AS THE LOW BATTERY ICON APPEARS 1 Digit 2 3 Digit Display 3 Voltage AC Range 4 Mode Dial 5 Current DC Range 6 Diode Continuity Check 7 Red Test Probe 8 Black Test Probe 9 10A Port 10 VmAΩ Port 11 COM Port 12 Black Test Lead 13 Red Test Lead 14 Resistance Rang...

Page 3: ...how up as a 000 onscreen Finding The Measuring Range The multimeter needs to be set to the lowest possible range in order to reduce the amount of inaccuracy in the readings If you are unsure of the range to start off with it is best to set the mode dial to the highest range setting take a measurement to obtain a ballpark figure and then use that figure to adjust the mode dial accordingly For examp...

Page 4: ...nt AC This multimeter could be used to check wall outlets with the right accessories and knowledge WARNING CHECKING WALL FIXTURES REQUIRES LIVE CIRCUITRY WHICH CAN BE EXTREMELY DANGEROUS ONLY PERFORM THIS IF YOU ARE ABSOLUTELY SURE OF WHAT YOU RE DOING CONSULT A QUALIFIED PROFESSIONAL ELECTRICIAN INSTEAD IF YOU HAVE ANY DOUBT WARNING NEVER TOUCH THE BARE METAL PORTION OF THE PROBES DOING SO COULD ...

Page 5: ...nstead In which case do not set the mode dial to 10A rather follow the procedure for finding the measuring range mentioned previously 3 Switch off the power in the circuit under scrutiny and discharge all capacitors if there are any 4 Disconnect the negative lead of the last item in the circuit from the negative terminal of the battery and secure it to the red test probe of the multimeter Here is ...

Page 6: ... much forward voltage is dropped across it Diodes are always polarised which means they only allow current to flow in one direction across them An LED is a common example of a diode Note This multimeter displays the forward voltage reading in mV 1 Connect the black test lead to the black COM port and the red test lead to the red VmAΩ port on the multimeter 2 Set the mode dial to the diode contunui...

Page 7: ...nce Ensure that no water can get into the interior of the appliance Dirt or moisture in ther ports can affect readings Periodically clean them out with the following directions 1 Ensure the mode dial is in the OFF position and the test leads are removed 2 Shake out any loose dirt which may be caught in the terminals 3 Soak a swab in cleaning alcohol 4 Work the swab around the interior of each term...

Page 8: ...r or dust is present DO NOT apply more than the rated voltage as marked on the meter between terminals or between any terminal and earth ground ALWAYS verify the meter s operation by measuring a known voltage before use ALWAYS turn off circuit power before connecting the meter in the circuit to measure current Remember to place the meter in series with the circuit ALWAYS turn off circuit power bef...

Reviews: