background image

Standard Charging Programs

 12V STD:

Charging program for lead acid batteries (wet, Ca/Ca, EFB 
batteries) and gel batteries. When the charger is used for the first 
time, 12V STD will appear in the display.

 12V AGM:

Charging program for AGM batteries Press the “Mode” button –> 
switch from the 12V STD to the 12V AGM charging program.

Special Charging Programs

 Winter:

The recommended charging program for cold weather 
conditions (ambient temperature of -20°C to +5°C) for 
normal lead acid batteries (wet / Ca/Ca batteries) Press the 
“Mode” button –> switch from the 12V AGM to the “Winter” 
charging program.

 12V M  - Maintenance Mode:

Charging program for batteries with a low capacity (max. 1A)  
2 - 32Ah and for trickle charging of all batteries. Press the “Mode” 
button –> switch from the “Winter” to the “12 M” charging 
program.

 RECOND - Restoration Charging:

Charging program with higher end-of-charge voltage and constant 
current charging, used only for restoring the charging capability 
of lead acid batteries (not for AGM or GEL) which have undergone 
exhaustive discharge. Only use this program for a short time and 
under supervision.
The RECOND process must be checked every half an hour and 
must never exceed a time of 4 hours. Refer to the instructions 
supplied by the battery manufacturer.

Only use the RECOND program for lead acid batteries and only 
as described below. Take care to avoid spilling any battery 
acid. Battery acid is aggressive. Read and observe the safety 
information.
Never use for a battery which is of sealed design (VRLA battery 
such as, e.g. AGM or GEL battery). Refer to the instructions 
supplied by the battery manufacturer.
Only use for batteries which are free-standing and have been 
taken out of the car, not while installed in your car with a 
connection to the car’s electrical system. The higher charging 
voltage could damage the electrical system.

Note: 

To go to this program, the “Mode” button must be pressed 

for 5 seconds.

2. LCD SYMBOLS

3. CHARGING PROGRAMS

12V STD: 

Charging a 12V battery (lead acid battery and GEL 

battery.

12V AGM: 

Charging a 12V AGM battery.

Winter: 

Charging a 12V battery (lead acid battery, AGM battery 

and GEL battery) in winter mode with an ambient temperature of 
-20

°

C to +5

°

C.

12V M  - Maintenance Mode: 

Charging a 12V battery (lead 

acid battery, AGM battery and GEL battery) in charge maintenance 
mode.

Charging Volts: 

Charging voltage in volts, faulty battery (BAt) 

/ fully charged (FUL) / connected with reverse polarity or short-
circuit at the clamps (Err).

RECOND - Restoration Charging: 

Restoration of the charging 

capability of discharged lead acid batteries with higher charging 
voltage.

Warning - Fault Indictor:

 If the voltage of the battery is less than 3.5V or more than 15V. 

The battery is either unsuitable for charging or is defective. It is 
also possible that other battery errors or faults can mean that the 
battery cannot be charged.

 If the terminal clamps are connected to the battery terminals 

with the wrong polarity. The protection against swapped poles 
ensures that the battery and charger do not get damaged. Remove 
the charger from the battery and start the charging process from 
the beginning again.

 If there is a short-circuit between the two terminal clamps (the 

metal parts of the clamps come into contact with each other). 
The protection against short-circuits ensures that the battery and 
charger do not get damaged.

SUPPLY: 

Power supply - when charging a battery. Enables the 

battery charger to be used as a buffer power supply as well, e.g. 
while changing a battery or for the operation of 12V d.c. devices 
(function output max. 3A).

Charge Status: 

Charge status of the battery in percent (1 

increment = 25%) and charging process (increment lit = the 
battery has reached the charge level shown; increment in the 
battery symbol flashes = the battery is being charged to the next 
charge level; all increments are lit = the battery is fully charged).

WARNING! 

DO NOT CHARGE ANY FROZEN BATTERIES.

Summary of Contents for OCBC-400

Page 1: ...and Head Office 25 Fox Drive Dandenong South Victoria Australia 3175 ozito com au Battery Charger 0621 IN ORDER TO MAKE A CLAIM UNDER THIS WARRANTY YOU MUST RETURN THE PRODUCT TO YOUR NEAREST BUNNINGS...

Page 2: ...ING READ AND UNDERSTAND THE WARNINGS BEFORE SETUP AND CHARGING ONLINE MANUAL Scan this QR Code with your mobile device to take you to the online manual WARNING DO NOT USE FOR CHARGING LITHIUM ION PHOS...

Page 3: ...To go to this program the Mode button must be pressed for 5 seconds 2 LCD SYMBOLS 3 CHARGING PROGRAMS 12V STD Charging a 12V battery lead acid battery and GEL battery 12V AGM Charging a 12V AGM batte...

Page 4: ...WORK AND YOU PROCEED AS DESCRIBED ABOVE IN EXCEPTIONAL CASES IT IS POSSIBLE THAT THE POSITIVE BATTERY POLE IS CONNECTED TO THE BODYWORK POSITIVE EARTHING IN THIS CASE CONNECT THE BLACK CHARGER CABLE T...

Page 5: ...ll the cells Screw the battery stoppers if there are any tightly in place 12V STD To get back to the 12V STD program from the RECOND program or the SUPPLY function also press the Mode button for 5 sec...

Page 6: ...cement of the supply cord is necessary this has to be done by a certified electrician in order to avoid a safety hazard Note Ozito Industries will not be responsible for any damage or injuries caused...

Page 7: ...ordered from the Special Orders Desk at your local Bunnings Warehouse For further information visit www ozito com au or contact Ozito Customer Service Australia 1800 069 486 New Zealand 0508 069 486...

Page 8: ...t collection can reduce dust related hazards h Do not let familiarity gained from frequent use of tools allow you to become complacent and ignore tool safety principles A careless action can cause sev...

Reviews: