2. SYMBOLS
Battery Status
When illuminated
Battery charging status = 25%
Battery charging status = 50%
Battery charging status = 75%
Battery charging status = 100%
Error LED
When illuminated.
•
If the voltage of the battery is less than 3.5V or
more than 15V. The battery is either unsuitable
for charging or is defective. It is also possible
that other battery errors or faults can mean that
the battery cannot be charged.
•
If the terminal clamps are connected to the
battery terminals with the wrong polarity. The protection against
swapped poles ensures that the battery and charger do not get
damaged. Remove the charger from the battery and start the
charging process from the beginning again.
•
If there is a short-circuit between the two terminal clamps (the
metal parts of the clamps come into contact with each other).
The protection against short-circuits ensures that the battery
and charger do not get damaged.
Mode Status
When Illuminated
12V CHARGING = Normal operation.
Charging of a 12V battery (lead acid battery, AGM
battery and GEL battery). 2A charging current.
12V WINTER MODE = For batteries with low
capacity.
Charging of a 12V battery (lead acid battery, AGM
battery and GEL battery) in winter mode with
an ambient temperature of – 20°C to +5°C. 2A
charging current. Do not charge frozen batteries.
MAINTAIN MODE = Reduced maximum charge
current.
Charging of a 12V battery (lead acid battery, AGM
battery and GEL battery) in charge maintain mode.
Battery capacity 3 - 32Ah. 1A max. charging
current.