background image

   3. CONTROLS

Torch Light

Digital Display (PSI / BAR / KPa)

Preset Pressure

1   To turn the LED light on, press 

the light button in.

1   To switch between the 3 

pressure units, press the 

pressure units button.

1   Press the increase button to 

increase the preset pressure.

2   Press the decrease button to 

decrease the preset pressure.

2   To turn the LED light off, press 

the light button again.

Note:

  The compressor must be connected to the power for the LED 

torch to work.

The compressor has a built-in LED torch light for ease of use at night or 

in dark areas.

The digital pressure reading can be switched between PSI, BAR and 

KPa to match the requirements on the item being inflated.

 

While a high pressure item is inflating, the current air pressure will be 

displayed on the digital display.

A desired pressure can be preset and the compressor will automatically 

shut-off once the pressure is obtained. The preset pressure must be set 

before starting the tool.

  2. SWITCHING ON & OFF

Connecting to a 12V outlet

Switching On and Off

1   Roll out the 12V socket from 

the base of the unit.

1   To operate in high pressure 

mode, press the on/off switch 

forward into mode “I”.

The 2 in 1 Air compressor Inflator features 2 operating modes which are 

high pressure inflating or high volume inflating.

High Pressure Mode

 allows you to inflate items that require high 

pressures such as sporting equipment or car and bike tyres.

High Volume Mode

 allows fast inflation for large volume items such as 

an air bed or pool toys. 

2   Connect the 12V 

socket to a 12V DC 

outlet which can be 

found in your vehicle.

Note:

 Check car outlet 

for sufficient power of up 

to 120W.

2   To operate in high volume 

mode, press the on/off switch 

backward into mode “II”.

WARNING: 

COMPRESSED AIR CAN BE DANGEROUS. 

NEVER POINT THE OUTLET NOZZLE TOWARDS ANY 

PART OF YOUR BODY OR ANOTHER PERSON.

WARNING:

 

AVOID INFLATING THE OBJECTS ABOVE 

 

THE RECOMMENDED INFLATION PRESSURE. THIS MAY 

LEAD TO  DAMAGE AND/OR INJURIES. 

Summary of Contents for MCT-4000

Page 1: ...out within the instruction manual If the tool is disassembled or tampered with in any way Professional industrial or high frequency use WARRANTY TO ENSURE A SPEEDY RESPONSE PLEASE HAVE THE MODEL NUMBER AND DATE OF PURCHASE AVAILABLE A CUSTOMER SERVICE REPRESENTATIVE WILL TAKE YOUR CALL AND ANSWER ANY QUESTIONS YOU MAY HAVE RELATING TO THE WARRANTY POLICY OR PROCEDURE OZITO Australia New Zealand He...

Page 2: ...or Removing Adaptors Side Compartment Base Compartment 1 The general purpose adaptor and ball adaptor are stored in the side compartment 1 The 3 high volume adaptors are stores in the compartment in the base 2 The 12V socket is also stored in the compartment in the base 2 The high volume air hose is also stored on the side of the tool and can be removed be sliding out The compressor unit has 5 ada...

Page 3: ...ure is obtained The preset pressure must be set before starting the tool 2 SWITCHING ON OFF Connecting to a 12V outlet Switching On and Off 1 Roll out the 12V socket from the base of the unit 1 To operate in high pressure mode press the on off switch forward into mode I The 2 in 1 Air compressor Inflator features 2 operating modes which are high pressure inflating or high volume inflating High Pre...

Page 4: ...ff After the tool has automatically shut off press the on off switch into the off position O IMPORTANT BEFORE CONNECTING OR DISCONNECTING ACCESSORIES ALWAYS MAKE SURE THAT THE COMPRESSOR IS OFF 2 Insert the adaptor into the item to be inflated 4 Press the on off switch forward into mode I to inflate high pressure items 6 Remove the adaptor from the inflatable item 1 Screw the ball or general purpo...

Page 5: ...or from the inflatable item 6 Remove the adaptor from the inflatable item 1 Remove the high volume air hose from its storage position and insert into the tools air outlet 1 Remove the high volume air hose from its storage position and insert into the tools air inlet 3 Insert the adaptor into the inflatable item Note If the inflatable item has a cap or air lock ensure it is removed or unlocked to a...

Page 6: ...Compressor not connected to the power Plug the 12V socket into a 12V outlet Low pressure items such as sporting equipment not being fully inflated Internal line pressure of the inflation hose exceeds preset pressure Increase the preset pressure on the LCD display and switch the compressor off when firm 1 Unscrew the top of the 12V socket to expose the fuse The 12V socket is fitted with a 10A fuse ...

Page 7: ...reign matter from entering the vents After each use blow air through the Compressor housing to ensure it is free from all dust particles which may build up Build up of dust particles may cause the Compressor to overheat and fail If the enclosure of the Compressor requires cleaning do not use solvents but a moist soft cloth only Never let any liquid get inside the Compressor never immerse any part ...

Page 8: ...supply Use of an RCD reduces the risk of electric shock 3 Personal safety a Stay alert watch what you are doing and use common sense when operating a power tool Do not use a power tool while you are tired or under the influence of drugs alcohol or medication A moment of inattention while operating power tools may result in serious personal injury b Use personal protective equipment Always wear eye...